PROBLEM 

 

POSSIBLE CAUSE 

 

ACTION 

 

Agitator is not working.  

Check to be certain the 
stirrer blade is on the 
bottom of the pan and is 
stirring the corn.  

Check motor connections.  

Loose wire.  

The motor is bad.  

Replace.  

The correct amount of corn and oil 
were not used.  

See Operations Manual for 
correct amounts.  

Corn Burns  

Temperature is set too high.  

Adjust temperature.  
  

Kettle leaks 
oil at 
agitator.  

If the kettle is not cleaned on a regular 
basis the popping oil will build up and 
turn to carbon on the inside of the 
blade center.  When this happens the 
clearance between the blade center 
and the pan center is reduced from 
1/8” (3mm).  As this clearance is 
reduced, the oil will “wick” up the 
narrow space and run down the 
rotating shaft and it will appear that 
the kettle is leaking for 20 oz. kettles.   

When reassembling, lightly 
coat the clutch dog shaft 
with moly grease or a 
comparable high 
temperature lubricant.  

Pump will 
not heat.  

Pump switch is on.  

Check pump switch.  
Remove wires from switch 
(mark wires for proper re-
installation.)  Using a 
multimeter, check for 
continuity from top to 
bottom of switch.  If no 
continuity, replace switch.  

 

  

Содержание EG20

Страница 1: ...and Three Phase 60 Hz 120 240 Volt Single and Three Phase 60 Hz 230 Volt Single Phase 50 Hz 400 Volt Three Phase 50 Hz 100 200 Volt Single Phase 50 60 Hz Included in this manual One Pop Option Salt S...

Страница 2: ...ons 6 A Location B Power Supply C Connecting Machine to Power Supply D OEM Option Pedestals 7 E Pump Installation Timer Adjustment for Salt Sugar Machines VII Service Instructions 8 A Parts B Kettle T...

Страница 3: ...f 29 CFR 1926 20 b 4 a 2 It is understood that safety rules within individual companies vary If a conflict exists between the safety procedures contained in this manual and the rules of a using compan...

Страница 4: ...EG20 32 48 60 M A E S Last printed 9 10 2007 1 56 00 PM 4 BEGIN SERIAL NO 00035540 CONFIGURATOR PAGE...

Страница 5: ...P Capacity 32 oz All Steel Kettle 640 one ounce servings per hour Wattage 4500 watts Dimensions 10 5 8 D x 10 1 2 W x 31 3 4 H 27 cm D x 26 cm W x 81 cm H Net Weight 74 lbs 33 6 kg MODEL EG48 GIANT 48...

Страница 6: ...the correct power source Failure to do so may result in personal injury or death and may damage your popper 2 C Cretors and Company recommends dedicated circuits for the Giant model popcorn machine Th...

Страница 7: ...ircuit only provides a switch it does not supply any power All electrical connections outside the pedestal must be done in accordance with appropriate electrical codes and requirements E Pump Installa...

Страница 8: ...operation The kettle indicator light indicates the operation of the temperature control If equipped the indicator light is located on the switch plate The indicator light will turn off 10 20 seconds b...

Страница 9: ...t out with the new kettle assemblies for reference 2 DIGITAL TEMPERATURE CONTROL ADJUSTMENT CAUTION If the corn has dried out it may not finish popping at normal temperatures and the light may appear...

Страница 10: ...10 to 20 seconds prior to dumping the kettle 4 SALT TIMER ADJUSTMENT For machines supplied with Salt Sugar Option only When the Salt Sugar switch is in the sugar mode the thermostat alone controls th...

Страница 11: ...the number side opposite of the open side Switch 6 5 seconds 7 10 seconds 8 20 seconds 9 40 seconds Example If you turn 7 and 9 on the time delay will be 50 seconds C Kettle Removal To remove the ket...

Страница 12: ...n front terminal left to right Black on back terminal 5 Replace the terminal box cover 6 Turn on the agitator motor and dump the kettle If the drive shaft does not engage and dis engages freely readju...

Страница 13: ...f no load is applied Once the kettle heat and auxiliaries are turned on the voltage may drop 5 to 10 volts Use an ammeter to diagnose Indicator light stays on Digital Control never reaches temp One of...

Страница 14: ...off one of the element terminals due to a loose connection In either case the kettle must be removed and the problem identified 1 Remove kettle See section Kettle Removal for instructions 2 Check for...

Страница 15: ...irs on the power supply circuit unless you are qualified to do so The electrical shock associated with line voltages can cause serious injury or death The following procedures are performed with the p...

Страница 16: ...2000 Watt 28 8 4250 Watt 13 6 total 48 oz 60 oz 208V elements 1010 D 1808 D 1447 D 1043 D 750 Watt 57 7 1250 Watt 34 7 1800 Watt 24 0 2000 Watt 21 6 5800 Watt 7 5 total 48 oz 60 oz 240V elements 1010...

Страница 17: ...g for heat and providing power to the relay contactor If the coil reading is not 120 volts 230 volts on 230V and 400V 50Hz machines the problem is in the temperature control 4 If the coil reading is 1...

Страница 18: ...on a regular basis the popping oil will build up and turn to carbon on the inside of the blade center When this happens the clearance between the blade center and the pan center is reduced from 1 8 3m...

Страница 19: ...rs and Company at the address listed below Please provide model and serial number when requesting additional copies of this manual There will be a nominal charge for additional copies Cretors guarante...

Отзывы: