EG20/32/48/60-M-A/E-S
Last printed 9/10/2007 1:56:00 PM
18
BEGIN SERIAL NO: 00035540
PROBLEM
POSSIBLE CAUSE
ACTION
Agitator is not working.
Check to be certain the
stirrer blade is on the
bottom of the pan and is
stirring the corn.
Check motor connections.
Loose wire.
The motor is bad.
Replace.
The correct amount of corn and oil
were not used.
See Operations Manual for
correct amounts.
Corn Burns
Temperature is set too high.
Adjust temperature.
Kettle leaks
oil at
agitator.
If the kettle is not cleaned on a regular
basis the popping oil will build up and
turn to carbon on the inside of the
blade center. When this happens the
clearance between the blade center
and the pan center is reduced from
1/8” (3mm). As this clearance is
reduced, the oil will “wick” up the
narrow space and run down the
rotating shaft and it will appear that
the kettle is leaking for 20 oz. kettles.
When reassembling, lightly
coat the clutch dog shaft
with moly grease or a
comparable high
temperature lubricant.
Pump will
not heat.
Pump switch is on.
Check pump switch.
Remove wires from switch
(mark wires for proper re-
installation.) Using a
multimeter, check for
continuity from top to
bottom of switch. If no
continuity, replace switch.