Cretors EG20 Скачать руководство пользователя страница 11

  

EG20/32/48/60-M-A/E-S 

Last printed 9/10/2007 1:56:00 PM 

11 

BEGIN SERIAL NO: 00035540 

  

5.

 

SALT/SUGAR WITH ONE POP ADJUSTMENT 

 
a.

 

If the Salt/Sugar switch is in the sugar position, use the “Digital 
Temperature Control Adjustment” section. 
 

b.

 

If the Salt/Sugar switch is in the salt position, the temperature is adjusted on 
the One Pop Timer/Relay. 
 

c.

 

On the Relay there are dip switches very similar to the timer in our 7700-7900 
pumps. 
 

d.

 

From the factory the dip switches 7 and 9 will be on. To turn the dip switches 
ON the dip switch needs to be pressed down to the number side opposite of 
the open side. 

 

 
 
 
 

 

 
 

Switch #6  = 5 seconds 

#7  = 10 seconds 
#8  = 20 seconds 
#9  = 40 seconds 

 

       Example: If you turn #7 and #9 on, the time delay will be 50 seconds. 

 

 

 

C.

 

Kettle Removal

 

 

To remove the kettle assembly, perform the following operations:  

  
1.

 

Unplug the popcorn machine from the power supply.  Make sure the kettle 
is not hot.  

  

2.

 

Remove the cover on the terminal box between the pan support legs.  

  

3.

 

Disconnect the three power leads, observing the color of the wires.  Correct 
color code is:  Left to right,  BLACK, RED, WHITE.  (For 400V units BLUE, 
BROWN, WHITE on front terminal left to right, Black on back terminal.)  

  

4.

 

Remove the two bolts on the side of the aluminum pan legs.  

 

 

 

 

 

 

 

Using proper lifting techniques, when removing the kettle by lifting it 
straight up.  

 

 

Содержание EG20

Страница 1: ...and Three Phase 60 Hz 120 240 Volt Single and Three Phase 60 Hz 230 Volt Single Phase 50 Hz 400 Volt Three Phase 50 Hz 100 200 Volt Single Phase 50 60 Hz Included in this manual One Pop Option Salt S...

Страница 2: ...ons 6 A Location B Power Supply C Connecting Machine to Power Supply D OEM Option Pedestals 7 E Pump Installation Timer Adjustment for Salt Sugar Machines VII Service Instructions 8 A Parts B Kettle T...

Страница 3: ...f 29 CFR 1926 20 b 4 a 2 It is understood that safety rules within individual companies vary If a conflict exists between the safety procedures contained in this manual and the rules of a using compan...

Страница 4: ...EG20 32 48 60 M A E S Last printed 9 10 2007 1 56 00 PM 4 BEGIN SERIAL NO 00035540 CONFIGURATOR PAGE...

Страница 5: ...P Capacity 32 oz All Steel Kettle 640 one ounce servings per hour Wattage 4500 watts Dimensions 10 5 8 D x 10 1 2 W x 31 3 4 H 27 cm D x 26 cm W x 81 cm H Net Weight 74 lbs 33 6 kg MODEL EG48 GIANT 48...

Страница 6: ...the correct power source Failure to do so may result in personal injury or death and may damage your popper 2 C Cretors and Company recommends dedicated circuits for the Giant model popcorn machine Th...

Страница 7: ...ircuit only provides a switch it does not supply any power All electrical connections outside the pedestal must be done in accordance with appropriate electrical codes and requirements E Pump Installa...

Страница 8: ...operation The kettle indicator light indicates the operation of the temperature control If equipped the indicator light is located on the switch plate The indicator light will turn off 10 20 seconds b...

Страница 9: ...t out with the new kettle assemblies for reference 2 DIGITAL TEMPERATURE CONTROL ADJUSTMENT CAUTION If the corn has dried out it may not finish popping at normal temperatures and the light may appear...

Страница 10: ...10 to 20 seconds prior to dumping the kettle 4 SALT TIMER ADJUSTMENT For machines supplied with Salt Sugar Option only When the Salt Sugar switch is in the sugar mode the thermostat alone controls th...

Страница 11: ...the number side opposite of the open side Switch 6 5 seconds 7 10 seconds 8 20 seconds 9 40 seconds Example If you turn 7 and 9 on the time delay will be 50 seconds C Kettle Removal To remove the ket...

Страница 12: ...n front terminal left to right Black on back terminal 5 Replace the terminal box cover 6 Turn on the agitator motor and dump the kettle If the drive shaft does not engage and dis engages freely readju...

Страница 13: ...f no load is applied Once the kettle heat and auxiliaries are turned on the voltage may drop 5 to 10 volts Use an ammeter to diagnose Indicator light stays on Digital Control never reaches temp One of...

Страница 14: ...off one of the element terminals due to a loose connection In either case the kettle must be removed and the problem identified 1 Remove kettle See section Kettle Removal for instructions 2 Check for...

Страница 15: ...irs on the power supply circuit unless you are qualified to do so The electrical shock associated with line voltages can cause serious injury or death The following procedures are performed with the p...

Страница 16: ...2000 Watt 28 8 4250 Watt 13 6 total 48 oz 60 oz 208V elements 1010 D 1808 D 1447 D 1043 D 750 Watt 57 7 1250 Watt 34 7 1800 Watt 24 0 2000 Watt 21 6 5800 Watt 7 5 total 48 oz 60 oz 240V elements 1010...

Страница 17: ...g for heat and providing power to the relay contactor If the coil reading is not 120 volts 230 volts on 230V and 400V 50Hz machines the problem is in the temperature control 4 If the coil reading is 1...

Страница 18: ...on a regular basis the popping oil will build up and turn to carbon on the inside of the blade center When this happens the clearance between the blade center and the pan center is reduced from 1 8 3m...

Страница 19: ...rs and Company at the address listed below Please provide model and serial number when requesting additional copies of this manual There will be a nominal charge for additional copies Cretors guarante...