EG20/32/48/60-M-A/E-S 

Last printed 9/10/2007 1:56:00 PM 

10 

BEGIN SERIAL NO: 00035540 

  

3.

 

CHECKING TEMPERATURE CONTROL

 

 

There are two ways of checking that the temperature control is set 
correctly. 
 
a.

 

Place the pyrometer over the thermocouple position and turn the 
kettle heat on. Watch to see that the kettle heat shuts off at the correct 
temperature. Make adjustments as needed. 
 

b.

 

The temperature control may be adjusted by observing the operation 
of the indicator light as described in the “Temperature Control 
Operation” section.  Adjust the temperature control so that the kettle 
heat is turned off 10 to 20 seconds before the corn finishes popping 
and the kettle is dumped. 

 

  

Do not adjust the temperature so high that the pan smokes at the end of 
the popping cycle.  If set too high (over 500°F or 260°C), the kettle can 
become a serious fire hazard.   

 

c.

 

 

Observe two or three cycles of correct operation to be certain 

everything is working correctly. Your final setting should allow the 
indicator light to cycle off 10 to 20 seconds prior to dumping the kettle. 

  

4.

 

SALT TIMER ADJUSTMENT (For machines supplied with Salt/Sugar 
Option only) 

 

When the Salt/Sugar switch is in the sugar mode, the thermostat alone 
controls the heat.  When the switch is in the salt mode, the temperature 
control works the same way with the exception that when the temperature 
control opens, it activates a timer, which allows the heat to stay on for an 
extended period of time allowing the salted corn to pop.  The salt timer is 
located in the pedestal of all Giants marked “Salt Timer”.  In salt mode:  

  

a.

 

If the indicator light turns off 30 seconds or more before the corn 
finishes popping, the timer is set too low and is in need of adjustment.  

  

b.

 

There are two adjustments on the timer.  The small adjustment knob 
sets the maximum time the timer can run.  Cretors will normally set this 
adjustment for 1m.  

10s = 0-10 seconds  

      

 

 

 

1m = 0-1 minute  

       

 

 

 

10m = 0-10 minutes  

  

c.

 

The larger adjustment knob sets the actual run time (percentage of time 
allowed by the small adjustment knob).  Example:  If the maximum 
setting is set for 1m and the large knob is set at .5, the timer will run for 
30 seconds.  In this case, the heat will stay on 30 seconds after the 
temperature control opens.  

  

Содержание EG20

Страница 1: ...and Three Phase 60 Hz 120 240 Volt Single and Three Phase 60 Hz 230 Volt Single Phase 50 Hz 400 Volt Three Phase 50 Hz 100 200 Volt Single Phase 50 60 Hz Included in this manual One Pop Option Salt S...

Страница 2: ...ons 6 A Location B Power Supply C Connecting Machine to Power Supply D OEM Option Pedestals 7 E Pump Installation Timer Adjustment for Salt Sugar Machines VII Service Instructions 8 A Parts B Kettle T...

Страница 3: ...f 29 CFR 1926 20 b 4 a 2 It is understood that safety rules within individual companies vary If a conflict exists between the safety procedures contained in this manual and the rules of a using compan...

Страница 4: ...EG20 32 48 60 M A E S Last printed 9 10 2007 1 56 00 PM 4 BEGIN SERIAL NO 00035540 CONFIGURATOR PAGE...

Страница 5: ...P Capacity 32 oz All Steel Kettle 640 one ounce servings per hour Wattage 4500 watts Dimensions 10 5 8 D x 10 1 2 W x 31 3 4 H 27 cm D x 26 cm W x 81 cm H Net Weight 74 lbs 33 6 kg MODEL EG48 GIANT 48...

Страница 6: ...the correct power source Failure to do so may result in personal injury or death and may damage your popper 2 C Cretors and Company recommends dedicated circuits for the Giant model popcorn machine Th...

Страница 7: ...ircuit only provides a switch it does not supply any power All electrical connections outside the pedestal must be done in accordance with appropriate electrical codes and requirements E Pump Installa...

Страница 8: ...operation The kettle indicator light indicates the operation of the temperature control If equipped the indicator light is located on the switch plate The indicator light will turn off 10 20 seconds b...

Страница 9: ...t out with the new kettle assemblies for reference 2 DIGITAL TEMPERATURE CONTROL ADJUSTMENT CAUTION If the corn has dried out it may not finish popping at normal temperatures and the light may appear...

Страница 10: ...10 to 20 seconds prior to dumping the kettle 4 SALT TIMER ADJUSTMENT For machines supplied with Salt Sugar Option only When the Salt Sugar switch is in the sugar mode the thermostat alone controls th...

Страница 11: ...the number side opposite of the open side Switch 6 5 seconds 7 10 seconds 8 20 seconds 9 40 seconds Example If you turn 7 and 9 on the time delay will be 50 seconds C Kettle Removal To remove the ket...

Страница 12: ...n front terminal left to right Black on back terminal 5 Replace the terminal box cover 6 Turn on the agitator motor and dump the kettle If the drive shaft does not engage and dis engages freely readju...

Страница 13: ...f no load is applied Once the kettle heat and auxiliaries are turned on the voltage may drop 5 to 10 volts Use an ammeter to diagnose Indicator light stays on Digital Control never reaches temp One of...

Страница 14: ...off one of the element terminals due to a loose connection In either case the kettle must be removed and the problem identified 1 Remove kettle See section Kettle Removal for instructions 2 Check for...

Страница 15: ...irs on the power supply circuit unless you are qualified to do so The electrical shock associated with line voltages can cause serious injury or death The following procedures are performed with the p...

Страница 16: ...2000 Watt 28 8 4250 Watt 13 6 total 48 oz 60 oz 208V elements 1010 D 1808 D 1447 D 1043 D 750 Watt 57 7 1250 Watt 34 7 1800 Watt 24 0 2000 Watt 21 6 5800 Watt 7 5 total 48 oz 60 oz 240V elements 1010...

Страница 17: ...g for heat and providing power to the relay contactor If the coil reading is not 120 volts 230 volts on 230V and 400V 50Hz machines the problem is in the temperature control 4 If the coil reading is 1...

Страница 18: ...on a regular basis the popping oil will build up and turn to carbon on the inside of the blade center When this happens the clearance between the blade center and the pan center is reduced from 1 8 3m...

Страница 19: ...rs and Company at the address listed below Please provide model and serial number when requesting additional copies of this manual There will be a nominal charge for additional copies Cretors guarante...

Отзывы: