SAFETY NOTES
GAS REQUIREMENTS
LIQUID PROPANE
Your fire table is not provided with a propane tank. You will need to provide one. Use the following specifications for purchasing your
propane tank.
Make sure your 20 lb. propane gas supply cylinder is constructed and marked in accordance with the specifications for propane gas
cylinders as required by the U.S. Department of Transportation (DOT), Specifications for LP-Gas Cylinders or the Standard for Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA B339, as applicable.
Manifold Pressure:
For plumbed-in liquid propane installation, use a regulator. Maximum line pressure for plumbed-in propane is 14” W.C.
psi (3.5 kPa). Minimum line pressure for propane is 11” W.C. The unit must be used with the supplied gas pressure regulator and hose
assembly. The regulator will control and maintain a uniform gas pressure in the manifold. The burner orifice has been sized for the gas
pressure delivered by the regulator. Replacement pressure regulator and hose assemblies must be those specified in this manual.
Any propane gas supply cylinder used with this fire table must be approximately 12” in diameter and 18” high. The maximum fuel capacity is
20 lbs. of propane, or 5 gallons. Full cylinder weight should be approximately 38 lbs. (43.7 lbs. nominal water capacity.) Always use the
cylinder dust cap on the cylinder valve outlet during transport and when the cylinder is not connected to the fire table. The 20 lb. propane
gas cylinder used must include a collar to protect the cylinder valve.
Filler Valve:
If you do not have an updated filler valve on your existing propane tank, you will need to purchase one at your local hardware
store, as you will not be allowed to refill the tank at any filling station.
Transporting Gas Cylinder:
Only one cylinder should be transported at a time. Transport cylinder in an upright and secure manner with
control valve turned off and the dust cap in place.
NATURAL GAS
Ensure that the service supplying the fire table is fitted with a conveniently positioned shut off valve with easy access. The shut-off valve
MUST NOT be inside the appliance!
Requirements:
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the fire table is
manufactured for. The installation of this appliance must conform with local codes or, in the absence of local codes, to the National Fuel
Gas Code, ANSI Z223.1, NFPA 54; National Fuel Gas Code; Natural Gas and Propane Installation Code, CSA B149.1; or Propane
Storage and Handling Code, CSA B146.2, as applicable. Natural gas connection must be performed by a licensed contractor or local gas
company representative. Ensure that the service supplying the fire table is fitted with a conveniently positioned shut off valve with easy
access.
PRESSURE TESTING
If this fire table is installed with a fixed fuel piping system and equipped with an appliance gas pressure regulator, the fire table and its
individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of the system at test pressures
in excess of ½ psi (3.5 kPa). The fire table must be isolated from the gas supply piping system by closing its individual manual shut-off valve
during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
FIRE TABLES ARE DESIGNED FOR OUTDOOR USE ONLY
Never locate this appliance in a building, garage or other enclosed room, under a sealed overhead structure, or in any enclosed area such as a
shed or breezeway. Keep clear of trees and shrubs. Do not place fire table under or near windows or vents that can be opened into your
home. Maintain sufficient distance so as to not overheat any overhead combustible material such as a patio cover. The area surrounding your
fire table should be kept clean and free from flammable liquids and other combustible materials such as mops, rags or brooms, as well as
solvents, cleaning fluids, and gasoline. Do not block the vents located near the base of your fire table as gas may build up in case of leak and
cause serious damage. Do not locate appliance where it can get excessively wet. Do not use this appliance if any part has been underwater.
Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which
has been underwater.
05
User’s Manual
715-293-3101
[email protected]