background image

Isys

®

 9” Wall Mount Touch Screen 

 

Crestron 

TPMC-9L

 

Setup 

Network Wiring 

When wiring the Cresnet network, consider the following: 

• 

Use Crestron Certified Wire. 

• 

Use Crestron power supplies for Crestron equipment. 

• 

Provide sufficient power to the system. 

CAUTION:

  Insufficient power can lead to unpredictable results or damage 

to the equipment. Use the Crestron Power Calculator to help calculate how 
much power is needed for the system (

www.crestron.com/calculators

). 

For networks with 20 or more devices, use a Cresnet Hub/Repeater (CNXHUB) to 
maintain signal quality. 

For more details, refer to “Check Network Wiring” on page 45. 

The TPMC-9L can also use high-speed Ethernet for communications between the 
device and a control system, computer, media server and other IP-based devices. 

For information on connecting Ethernet devices in a Crestron system, refer to the 
latest version of the Crestron e-Control

 Reference Guide (Doc. 6052), which is 

available from the Crestron Web site (

www.crestron.com/manuals

). 

Identity Code 

Net ID 

The Net ID of the TPMC-9L has been factory set to 

03

. The Net IDs of multiple 

TPMC-9L devices in the same system must be unique. The Net ID is set using the 
internal setup menu (refer to “Cresnet” on page 20). Net ID may also be set from a 
personal computer (PC) via Crestron Toolbox™ (refer to “Establishing 
Communication” whi
ch starts on page 41). 

When setting the Net ID, consider the following:

 

• 

The Net ID of each unit must match an ID code specified in the SIMPL 
Windows program. 

• 

Each network device must have a unique Net ID. 

For more details, refer to the Crestron Toolbox help file. 

IP ID 

The IP ID is set within the TPMC-9L’s IP table using the internal setup menu (refer 
to “IP Table” which starts on page 16). IP ID may also be set from a PC via Crestron 
Toolbox. For information on setting an IP table, refer to the Crestron Toolbox help 
file. The IP IDs of multiple TPMC-9L devices in the same system must be unique. 

When setting the IP ID, consider the following: 

• 

The IP ID of each unit must match an IP ID specified in the SIMPL 
Windows program. 

• 

Each device using IP to communicate with a control system must have a 
unique IP ID. 

12  

  Isys

®

 9” Wall Mount Touch Screen: TPMC-9L 

Operations & Installation Guide – DOC. 7030B 

Содержание TPMC-9L

Страница 1: ...Crestron TPMC 9L Isys 9 WallMountTouchScreen Operations Installation Guide...

Страница 2: ...particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to...

Страница 3: ...Programming Software 33 Software Requirements for the PC 33 Programming with Crestron SystemBuilder 33 Programming with SIMPL Windows 33 Programming with VisionTools 36 Push Button Programming 40 Upl...

Страница 4: ......

Страница 5: ...or in wall and lectern installation Generous 9 229 mm widescreen color touch screen 16 bit color graphics powered by Core 3 800 x 480 WVGA display resolution Automatic brightness control Native H 264...

Страница 6: ...3 UI enhancements Cool looking graphical buttons sliders knobs and gauges are intuitive and fun to use Kinetic effects enhance the feeling of realism with lists and toolbars that scroll with momentum...

Страница 7: ...gral to the faceplate the push buttons are positioned along the left and right edges of the touch screen making it possible to align them with text and graphics onscreen Custom engraving of the button...

Страница 8: ...ouch Screen Crestron TPMC 9L Applications The following diagram shows a TPMC 9L in a typical application TPMC 9L in a Typical Application 4 Isys 9 Wall Mount Touch Screen TPMC 9L Operations Installati...

Страница 9: ...grammable supports pre Core 3 projects Communications Ethernet 10 100 auto switching auto negotiating auto discovery full half duplex DHCP for control and console Cresnet Cresnet slave mode for contro...

Страница 10: ...T Isys 9 Wall Mount Touch Screen White Textured Included Accessories TPMC 9L FP A B W T_BLANK Button Faceplate without Engraving specify color TPMC 9L FP A B W T NB No button Faceplate specify color...

Страница 11: ...ed from the Crestron Web site Refer to the NOTE following these footnotes 3 Crestron 2 Series control systems include the AV2 and PRO2 Consult the latest Crestron Product Catalog for a complete list o...

Страница 12: ...cription This section provides information on the connections controls and indicators available on the TPMC 9L TPMC 9L Physical View TPMC 9L Physical View With No Button Faceplate 8 Isys 9 Wall Mount...

Страница 13: ...in 275 mm 7 52 in 191 mm Light Sensor Microphone 1 1 86 in 48 mm 0 38 in 10 mm 0 39 in 10 mm TPMC 9L Overall Dimensions Front and Side Views 1 68 in 43 mm 1 47 in 38 mm 10 63 in 270 mm 10 69 in 272 m...

Страница 14: ...nsole port behind faceplate Mini B to A USB cable included 4 VIDEO BAL 2 BAL S 1 3 pin 3 5 mm detachable terminal block Balanced composite video input Input impedance 100 nominal Input level 1 Vp p no...

Страница 15: ...G Ground 7 LAN Green LED Yellow LED Pin 8 Pin 1 1 8 wire RJ 45 with two LED indicators 10 100BASE T Ethernet port Green LED indicates link status Yellow LED indicates Ethernet activity PIN SIGNAL PIN...

Страница 16: ...ID The Net ID of the TPMC 9L has been factory set to 03 The Net IDs of multiple TPMC 9L devices in the same system must be unique The Net ID is set using the internal setup menu refer to Cresnet on pa...

Страница 17: ...left lower left upper right lower right This sequence must be performed within five seconds and touches must be all the way in the corners An third way to enter the setup screens for TPMC 9L touch scr...

Страница 18: ...s for setting up IP address and DNS servers Touch IP Address Settings to enter the IP Address screen shown in the illustration below Touch Return to go back to the main Setup menu IP Address Screen DH...

Страница 19: ...e IP Address screen The IP Address screen changes to show these addresses as shown in the illustration below IP Address Screen Showing DNS and WINS Servers Touch the appropriate button for the address...

Страница 20: ...entries Touch the Auto Discovery Enabled button to toggle to Auto Discover Disabled A Control Connection indicator lights in green to show a control system connection Touch Cresnet to enter a Cresnet...

Страница 21: ...ppropriate button Touching the Port 41794 button opens the numeric keypad Touching the CIP ID or Device ID buttons opens a hex keypad shown in the illustration below Hex Keypad Touch CLEAR to remove a...

Страница 22: ...Interface menu refer to illustration on page 16 On the Control System Interface menu touch Return to go back to the main Setup menu Video From the main Setup menu touch Video to enter the Video Setup...

Страница 23: ...ll Screen Video Display Touch Hide Controls to remove the controls The button text changes to Show Controls Touch Return to go back to the Video Setup screen From the Video Setup screen touch Return t...

Страница 24: ...resnet From the main Setup menu touch Cresnet to enter the Cresnet Interface screen shown in the illustration below Cresnet Interface Screen The Cresnet Interface screen contains buttons for setting t...

Страница 25: ...Status indicator lights in green to show Ethernet activity and a Control Connection indicator lights in green to show a control system connection The Light Sensor meter at the bottom of the screen pro...

Страница 26: ...shair appears at the center of the screen Touch the center of the crosshair which then moves to the upper left part of the screen Touch the center of the crosshair and it moves to another part of the...

Страница 27: ...o the Diagnostics menu From the Diagnostics menu touch Swipe Test to display the Swipe Test screen as shown in the illustration below Swipe Test Screen Swiping a finger on screen left to right right t...

Страница 28: ...9L Touch Return to go back to the main Setup menu Display From the main Setup menu touch Display to enter the Display Settings screen shown in the illustration below Display Settings Screen The Displ...

Страница 29: ...een brightness The Sensor Level meter is provided as a guide to setting the threshold Touch Return to go back to the main Setup menu Keypad From the main Setup menu touch Keypad to enter the Keypad Ba...

Страница 30: ...key backlighting to accommodate for the current room ambience The threshold value is constant for all bezel colors What the panel does when the sensor reading crosses the threshold differs for white a...

Страница 31: ...rsion of the RMK 9L Installation Guide Doc 7035 If the BB 9L or PMK 9L are to be used and a touch screen is not available the installer can either leave the hole in the mounting surface open if permit...

Страница 32: ...04 40 x 2 screws are for use with TPMC 9L mounting kits such as the BB 9L sold separately NOTE The following drawings are not to scale Do not attempt to use them to prepare the hole in the mounting su...

Страница 33: ...is level and trace the opening shape on the wall 4 Remove the template and then cut out and remove the traced shape to produce the required opening NOTE Before inserting the TPMC 9L in the mounting h...

Страница 34: ...Hookup which starts on page 31 7 Tighten the mounting screws evenly and only enough to compress the mounting clips and secure the TPMC 9L squarely in the mounting surface Do not over tighten the scre...

Страница 35: ...a The venting holes should not be obstructed under any circumstances If the TPMC 9L is hot to the touch consider using forced air ventilation To prevent overheating do not operate this product in an a...

Страница 36: ...th abrasive materials can scratch the surface which may detrimentally affect image quality For best cleaning results use a clean damp non abrasive cloth with any commercially available non ammonia gla...

Страница 37: ...is a comprehensive programming environment Appropriate for most systems it can quickly and easily generate a complete working program including both control processor logic and touch screen graphics P...

Страница 38: ...ow the TPMC 9L in the illustration the TPMC 9L Buttons and Gestures extender is visible The extender provides a set of signals that allow programmers to quickly identify when a hard key is pressed or...

Страница 39: ...h device Each TPMC 9L is assigned a different Net ID or IP ID number as it is added 3 If necessary double click a device to open the Device Settings window and change the Net ID or IP ID as shown in t...

Страница 40: ...dvanced VT Pro e high performance programming technique involving the TPMC 9L is the concept of multi mode objects A multi mode object i e button legend etc is an object drawn on a VT Pro e page that...

Страница 41: ...6 color table locations is assigned to a pixel A 16 bit highcolor system is considered sufficient to provide life like colors It is encoded using 5 bits to represent red 5 bits to represent blue and s...

Страница 42: ...mory space for the project In VT Pro e the Compress checkbox permits the image to be compressed when compiling The 16 Bits checkbox converts a 24 bit or 32 bit image to 16 bits This conversion to a 16...

Страница 43: ...rs cannot be interspersed with numbers Enter Chinese characters or numbers in separate strings or pad each number with x00 to make it multibyte and then combine it with Chinese characters in the same...

Страница 44: ...ently fixed digital join number The sequence of digital join numbers is top to bottom left to right 1 through 6 and 7 through 12 Refer to the following illustration A description for each button signa...

Страница 45: ...7 require Windows Mobile Device Center for communication with Toolbox Download and install Windows Mobile Device Center WMDC from the Microsoft Web site www microsoft com windowsmobile devicecenter m...

Страница 46: ...or later 3 Use the Address Book in Crestron Toolbox to create an entry for the TPMC 9L with the TPMC 9L s TCP IP communication parameters 4 Display the System Info window click the icon and select th...

Страница 47: ...9L and display the System Info window 2 Select Functions Firmware to upgrade the TPMC 9L firmware Program Checks Actions that can be performed on the TPMC 9L vary depending on whether it is connected...

Страница 48: ...am Touch screen Net ID is not unique two or more units share the same ID Use Crestron Toolbox to poll the network and verity that each ID is used only once No IP address configured obtained on the TPM...

Страница 49: ...equation to calculate the cable length value on the equation s left side Cable Length Equation L Length of run or chain in feet R 6 Ohms Crestron Certified Wire 18 AWG 0 75 mm or 1 6 Ohms Cresnet HP 1...

Страница 50: ...stron worldwide offices on the Crestron Web site www crestron com offices for assistance within a particular geographic region To post a question about Crestron products log onto the Online Help secti...

Страница 51: ...hased directly from Crestron or an authorized Crestron dealer Purchasers should inquire of the dealer regarding the nature and extent of the dealer s warranty if any Crestron shall not be liable to ho...

Страница 52: ...on Electronics Inc Operations Installation Guide DOC 7030B 15 Volvo Drive Rockleigh NJ 07647 2028354 Tel 888 CRESTRON 08 12 Fax 201 767 7576 Specifications subject to www crestron com change without n...

Отзывы: