Crestron
Serial Mouse Control Driver
Software
PORT
CONNECTOR to CONNECTOR
DEVICE
PORT
A
1
VGA
DB-15, male
DB-15, male
TPS-IMC-BV
RGB
B
2
RGB
RJ-45, 10-pin
RJ-45, 10-pin
Touchpanel
RGB
C
3
COM
DB-9, female
DB-9, female
Control System
COM
D
4
LAN
RJ-45, 8-pin
RJ-45, 8-pin
Ethernet / Hub
na
E
4
na
RJ-45, 8-pin
RJ-45, 8-pin
Touchpanel
LAN
F
5
na
na
TPS-IMC-BV
24VDC 2A
G
2
NET/VIDEO
RJ-45, 10-pin
RJ-45, 10-pin
Touchpanel
NET/VIDEO
1
2
3
4
5
REF
ETHERNET COMMUNICATION #2 - TILT TOUCHPANEL WITH TPS-XVGA-BV CARD
Standard Ethernet cables (ref D & E).
DEVICE
TO
FROM
CABLING REQUIRED
These connections (ref B & G) can be made with the 15-foot Triamese cable supplied with the TPS-IMC-BV. For
further information about the Triamese cable and other cabling options, refer to Appendix 3 on page 25 of this guide.
Control System
Ethernet / Hub
Standard stranded VGA monitor cable.
Power pack is NOT required if control system is connected to touchpanel via Ethernet AND Cresnet.
PWR. PACK
TPS-IMC-BV
Standard null modem serial cable.
TPS-IMC-BV
PC
PC
Ethernet Communication #3 - Lectern Touchpanel with TPS-XVGAL
RGB
INPUT
PORT
RGB CABLE
PC
LECTERN TOUCHPANEL
(OR TPS-TPI) WITH
TPS-XVGAL
COM
PORT
CONTROL
SYSTEM
ETHERNET
WIRING
ETHERNET
ROUTER/HUB
COM
PORT
LAN
PORT
VGA
PORT
LAN
PORT
A
COMM. CABLE
B
E
D
NET (OR
CRESNET)
PORT
CRESNET WIRING
TO
NET
PORT
C
BKLT
MENU
P ROFE SS I ONAL CONTROL PROCESSOR
PRO
2
CRESTRON
PORT
CONNECTOR to CONNECTOR
DEVICE
PORT
A
1
VGA
DB-15, male
BNC-5, male
Touchpanel
RGB
B
2
COM
DB-9, female
DB-9, female
Control System
COM
C
3
NET
4-wire Cresnet
4-wire Cresnet
Touchpanel
NET
D
4
LAN
RJ-45, 8-pin
RJ-45, 8-pin
Ethernet / Hub
na
E
4
na
RJ-45, 8-pin
RJ-45, 8-pin
Touchpanel
LAN
1
2
3
4
REF
ETHERNET COMMUNICATION #3 - LECTERN TOUCHPANEL WITH TPS-XVGAL CARD
TO
Standard Ethernet cables (ref D &E).
Ethernet / Hub
PC
PC
Control System
A standard stranded VGA monitor cable with DB15F to BNC-5 adapter is required. Both are commercially available.
DEVICE
FROM
CABLING REQUIRED
Cresnet wiring is required for touchpanel operating power only. For Cresnet 4-wire specifications, refer to Appendix
3 on page 25 of this guide.
Control System
Standard null modem serial cable.
2. Proceed to “
Ethernet Setup
” that begins
below
.
Ethernet Setup
Ethernet devices that are addressed by the control system may have their IP IDs set either in
the SIMPL Windows program or through the Crestron Viewport using a PC. Ultimately, each
IP ID is converted into an actual IP address through an IP table that exists inside the control
system. The IP Table is an internal list of information that contains the IP IDs and associated
IP addresses of all Ethernet devices in the program. The IP Table is accessed by the control
system to identify and locate Ethernet devices, for purposes of communication. Follow this
procedure to add the Serial Control Mouse Driver to the IP table of the touchpanel.
Programmer’s Guide - DOC. 5916A
Serial Mouse Control Driver
•
11