Crestron
Serial Mouse Control Driver
Software
Cresnet Communication #3 - Lectern Touchpanel with TPS-XVGAL
RGB
INPUT
PORT
RGB CABLE
PC
LECTERN TOUCHPANEL
(OR TPS-TPI) WITH
TPS-XVGAL
CRESNET
WIRING
COM
PORT
CONTROL
SYSTEM
NET
PORT
COM
PORT
VGA
PORT
NET (OR
CRESNET)
PORT
A
B
COMM. CABLE
C
BKLT
MENU
P ROFE SS I ONAL CONTROL PROCESSOR
PRO
2
CRESTRON
PORT
CONNECTOR to CONNECTOR
DEVICE
PORT
A
1
VGA
DB-15, male
BNC-5, male
Touchpanel
RGB
B
2
COM
DB-9, female
DB-9, female
Control System
COM
C
3
NET
4-wire Cresnet
4-wire Cresnet
Touchpanel
NET
1
2
3
Standard null modem serial cable.
For Cresnet 4-wire specifications, refer to Appendix 3 on page 25 of this guide.
PC
A standard stranded VGA monitor cable with DB15F to BNC-5 adapter is required. Both are commercially available.
Control System
PC
REF
CRESNET COMMUNICATION #3 - LECTERN TOUCHPANEL WITH TPS-XVGAL CARD
FROM
CABLING REQUIRED
TO
DEVICE
2. Proceed to “
SIMPL Windows Programming
” that begins on page
13
.
PC to Touchpanel Ethernet Communication
For Serial Mouse Control Driver operation using Ethernet communication from the PC to the
touchpanel, refer to the following two sections, Cabling Connections and Ethernet Setup.
NOTE:
To connect the LAN port on the control system and the LAN port on the touchpanel
base directly instead of through an Ethernet hub, use an Ethernet crossover cable (not
supplied).
NOTE:
A Crestron TPS-ENET or TPS-ENETL Ethernet expansion card must be installed in
the touchpanel to enable Ethernet communication. For further information, refer to the TPS-
ENET or TPS-ENETL Operations & Installation Guide (DOC. 5867 or 5829, respectively).
The latest revisions can be obtained from the Products page (PRODUCT MANUALS
section) or Downloads page (MANUAL Library) of Crestron’s website
(www.crestron.com)
.
New users are required to register to obtain access to the FTP site.
NOTE:
The Crestron control system must contain an Ethernet expansion card to enable
Ethernet communication. On CNX Generation control systems, the port may be labeled LAN
or LAN/DPA. On 2-Series control systems, the port may be labeled LAN A or LAN B. For
further information about CNX Generation Ethernet cards, refer to the CNXENET or
Operations & Installation Guide (DOC. 8129 or 8153, respectively). For further
information about 2-Series Ethernet cards, refer to the C2ENET Operations & Installation
Guide (DOC. 5962). The latest revisions can be obtained from the Products page (PRODUCT
MANUALS section) or Downloads page (MANUAL Library) of Crestron’s website
(www.crestron.com)
.
Programmer’s Guide - DOC. 5916A
Serial Mouse Control Driver
•