QuickSwitch HD HDMI Switcher
Crestron
HD-MD8X1/HD-MD8X2
12
QuickSwitch HD
HDMI Switcher: HD-MD8X1/HD-MD8X2
Operations & Installation Guide – DOC. 6714B
Setup
Network Wiring
When wiring the Cresnet and Ethernet network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
CAUTION:
Insufficient power can lead to unpredictable results or damage
to the equipment. Please use the Crestron Power Calculator to help calculate
how much power is needed for the system (
www.crestron.com/calculators
).
For Cresnet networks with 20 or more devices, use a Cresnet Hub/Repeater
(CNXHUB) to maintain signal quality.
For more details, refer to “Check Network Wiring” on page 23.
The HD-MD8X1/2 can also use high-speed Ethernet for communications between
the control system, computer, media server, and other IP-based devices.
For general information on connecting Ethernet devices in a Crestron system, refer to
the Crestron e-Control
Reference Guide (Doc. 6052) at
www.crestron.com/manuals
.
Identity Code
Net ID
The Net ID of the HD-MD8X1/2 has been factory set to
9B
. The Net IDs of multiple
HD-MD8X1/2 devices in the same system must be unique. Net IDs are changed
from a personal computer (PC) via Crestron Toolbox (refer to “Establishing
Communication” on page 18).
When setting the Net ID, consider the following:
The Net ID of each unit must match an ID code specified in the Crestron
Studio™ or SIMPL Windows program.
Each network device must have a unique Net ID.
For more details, refer to the Crestron Toolbox help file.
IP ID
The IP ID is set within the HD-MD8X1/2’s IP table using Crestron Toolbox. For
information on setting an IP table, refer to the Crestron Toolbox help file. The IP IDs
of multiple HD-MD8X1/2 devices in the same system must be unique.
When setting the IP ID, consider the following:
The IP ID of each unit must match an IP ID specified in the Crestron Studio
or SIMPL Windows program.
Each device using IP to communicate with a control system must have a
unique IP ID.