Problem Solving
Troubleshooting
The following table provides corrective action for possible trouble situations. If
further assistance is required, please contact a Crestron customer service
representative.
QM-RMCRX Troubleshooting
TROUBLE
POSSIBLE
CAUSE(S)
CORRECTIVE ACTION
PWR LED
does not
illuminate.
Control system is not
receiving power.
Verify that the DC output plug is properly
attached to the control system and that
the adaptor is securely plugged into an
outlet. Use only Crestron power supplies
for Crestron equipment.
Compilation
Error
RLCMCVT166
&
RLCMCVT177
Poor analog versus serial
signal definition in the
SIMPL Windows program.
Confirm properly defined signal
definition in the program.
System locks
up.
Various.
Press and release
HW-
R button then
hold
SW-R
to bypass the program.
Also refer to “Troubleshooting
Communications”
on
Various.
Refer to the “System Monitor” procedure
following this table.
System does
not function.
Incorrect power supply.
Use a Crestron power supply.
Troubleshooting continued on following page
32
•
QuickMedia™ Receiver/Processor: QM-RMCRX
Operations Guide - DOC. 6236A