QM-FTCC-TPS4
FE (Net ID 02 is reserved for master control units). The Net IDs reside within all
Cresnet devices (hardware) and must match the Net ID as specified in the software
(SIMPL Windows) that runs the system. Refer to “Setting the Net ID in Device
Settings” on page 27 for details of the SIMPL Windows procedure.
The Net ID of the QM module of the QM-FTCC-TPS4 has been factory set to
1A
.
The Net ID of the TPS4 touchpanel of the QM-FTCC-TPS4 has been factory set to
03
. The Net IDs of multiple QM-FTCC-TPS4s in the same system must be unique.
Net IDs can be changed from a personal computer (PC) using SystemBuilder
™
or
Crestron Toolbox.
NOTE:
For detailed information on establishing communication between the PC and
control system, refer to “Communication Settings” on page 32. If communication
cannot be established, refer to the “Troubleshooting Communications” section in the
latest version of the 2-Series Control System Reference Guide (Doc. 6256), which is
available from the Crestron website (http://www.crestron.com/manuals).
The Crestron Toolbox provides several methods to easily set or change device Net
IDs for any device on the network. The following method permits you to change the
Net ID of any device in the network through the “Network Device Tree” window.
NOTE:
This method prevents you from setting duplicate IDs.
This method permits you to manually set the Net ID for any device in the network,
can be used to set any known Net IDs that may require changing, and may also be
used for non-TSID equipment. This method will not permit you to choose an ID
already in use by another device. A warning message will appear if you attempt to
use an ID that is already in use.
Duplicate Net ID Warning Message
This method does not change the Net ID as assigned in SIMPL windows. Refer to
page 27 for the SIMPL Windows ID change procedure.
NOTE:
You may also use SystemBuilder to perform Network ID setup.
1. Ensure that all network devices are connected to the control system.
2. Open Crestron Toolbox and establish communications (refer to page 32).
3. Select the Network Device Tree
icon, or select
Tools | Network
Device Tree
. The Network Device Tree appears showing the current
devices on the network. (Refer to the following figure.)
14
•