Control System
Crestron
Lighting
Load Schedule w/ Panel Terminations
Project:
AV Sample Residence
Dealer:
Crestron
Creator:
Crestron D3 Pro v1.2.1
Date:
11/4/2003
System Number:
1
Description:
Area
Room
Controlled
Ckt Name
Controlled
Ckt No.
Fixture
Load Type
Dim Emergency
Fixture
Watts
Fixture
Qty
Total
Watts
Enclosure
Slot Module Output
Main
Floor
Bathroom
1
Downlights 009
Downlights Incandescent yes
no 100 1 100
Enclosure
1
2 CLX-
1DIM8
1
Main
Floor
Bathroom
1
Downlights 2
008
Downlights Incandescent yes
no
100
2
200
Enclosure
1
2 CLX-
1DIM8
2
Main
Floor
Bathroom
1
Downlights 3
006
Downlights Incandescent yes
no
100
2
200
Enclosure
1
2 CLX-
1DIM8
3
Main
Floor
Bathroom
1
Drapes 019
Drapes
3-Wire
Motor no
no 200
1
200
Enclosure
1
4 CLX-
1MC4
1
Main
Floor
Bathroom
1
Exhaust Fan
007
Exhaust
Fan
Switched
no
no
200
1
200
N / A
N /
A
Interface
2
1
Main
Floor
Bathroom
2
Downlights 011
Downlights Incandescent yes
no 100 1 100
Enclosure
1
2 CLX-
1DIM8
4
Main
Floor
Bathroom
2
Downlights 2
010
Downlights Incandescent yes
no
100
3
300
Enclosure
1
2 CLX-
1DIM8
5
Main
Floor
Bathroom
2
Drapes 021
Drapes
3-Wire
Motor no
no 200
1
200
Enclosure
1
4 CLX-
1MC4
2
Main
Floor
Bathroom
2
Exhaust Fan
012
Exhaust
Fan
Switched
no
no
200
1
200
N / A
N /
A
Interface
4
1
Main
Floor
Bedroom Ceiling
Fan
022
Ceiling
Fan
Ceiling Fan
no
no
100
1
100
Enclosure
1
6 CLX-
1FAN4
1
Main
Floor
Bedroom Downlights
005 Downlights Incandescent yes
no
250
2
500 Enclosure
1
2 CLX-
1DIM8
7
Main
Floor
Bedroom Downlights
2
004
Downlights Incandescent yes
no
100
4
400 Enclosure
1
3 CLX-
1DIM4
1
Main
Floor
Bedroom Downlights 3
003
Downlights Incandescent yes
no
100
1
100
N / A
N /
A
Interface
6
1
Main
Floor
Bedroom Downlights 4
002
Downlights Incandescent yes
no
100
1
100
N / A
N /
A
Interface
5
1
Main
Floor
Bedroom Downlights
5
001
Downlights Incandescent yes
no
100
2
200 Enclosure
1
3 CLX-
1DIM4
2
Main
Floor
Bedroom Drapes
018 Drapes
3-Wire
Motor no no
200 1 200 Enclosure
1
4 CLX-
1MC4
3
Main
Floor
Bedroom
Drapes 2
017
Drapes
3-Wire Motor no
no
200
1
200
Enclosure
1
4 CLX-
1MC4
4
Main
Floor
Bedroom
Drapes 3
016
Drapes
3-Wire Motor no
no
200
1
200
Enclosure
1
5 CLX-
1MC4
1
Main
Floor
Foyer Downlights 013 Downlights Incandescent yes
no
100 4 400 Enclosure
1
2 CLX-
1DIM8
6
Main
Floor
Sauna Drapes 020 Drapes
3-Wire
Motor no no 200 1 200
Enclosure
1
5 CLX-
1MC4
2
*Calculation of load wattage includes transformer loss.
The following three pages contain the complete application diagrams of this example
system, Circuits and Interfaces, Module Wiring, and PAC2 Connections, divided up
to fit the space available. The complete diagram is available on line at:
http://www.crestron.com/dealer-tech_resources/application_diagrams.asp
.
34
•
Lighting Control System Design
Design Guide – DOC. 5999A
Содержание Lighting Control System
Страница 1: ...Crestron Lighting Control System Design Guide ...
Страница 4: ......
Страница 40: ...Control System Crestron Lighting 36 Lighting Control System Design Design Guide DOC 5999A Module Wiring ...
Страница 41: ...Crestron Lighting Control System PAC2 Connections Design Guide DOC 5999A Lighting Control System Design 37 ...