DigitalMedia Presentation Systems
Crestron
DMPS-100/200/300-C/300-C-AEC
66
•
DigitalMedia Presentation Systems: DMPS-100/200/300-C/300-C-AEC
Operations Guide – DOC. 7219D
10.
At the Toolbox prompt, type
erase
and press
Enter
. The following text
appears in Toolbox:
Erasing
->25%->50%->75%->100%
Done
11.
Click the
icon and select
Firmware…
to display the “Firmware”
dialog box, then click
Browse
.
12.
Find and select the correct firmware file (.CUZ or .zip) and click
Open
.
13.
In the “Firmware” dialog box, click
Send
. A “Confirmation” dialog box
opens asking if the right file has been selected. Click
OK
to display the
“File Transfer” dialog box.
14.
When file transfer is completed, a dialog box opens requesting re-
connection. Click
OK
, then close the “Firmware” dialog box and re-connect
using the normal Address Book entry.
Network Analysis
If Cresnet analysis is required, contact Crestron’s True Blue Support.
Battery Replacement
A Lithium battery is used to power the system clock within the
DMPS-100/200/300-C. Under normal conditions, the battery lasts for approximately
10 years. In the event that the clock fails, only an authorized technician should
replace it. Refer to caution statement below.
CAUTION:
Danger of explosion if battery is incorrectly replaced. Replace only
with the same or equivalent type recommended by the manufacturer. Dispose of used
batteries according to the manufacturer's instructions.
Check Network Wiring
Use the Right Wire
To ensure optimum performance over the full range of the installation topology, use
Crestron Certified Wire only. Failure to do so may incur additional charges if
support is required to identify performance deficiencies because of using improper
wire.
Calculate Power
CAUTION:
Use only Crestron power supplies for Crestron equipment. Failure to
do so could cause equipment damage or void the Crestron warranty.
CAUTION:
Provide sufficient power to the system. Insufficient power can lead to
unpredictable results or damage to the equipment. Use the Crestron Power
Calculator to help calculate how much power is needed for the system
When calculating the length of wire for a particular Cresnet run, the wire gauge and
the Cresnet power usage of each network unit to be connected must be taken into
consideration. Use Crestron Certified Wire only. If Cresnet devices are to be daisy
chained on the run, the Cresnet power usage of each network unit to be daisy
chained must be added together to determine the Cresnet power usage of the entire
chain. If the unit is run from a Crestron system power supply network port, the
Cresnet power usage of that unit is the Cresnet power usage of the entire run. The