CKd Owner’s Manual
Module Installation
There are two modules through which a CKd amplifier can be connected to a
NexSys network – the NxDante8 Module and the NxCobranet8 Module. Although
they have different feature sets, they both serve the networking function. Because
of this, they are collectively referred to as “
NexSys network modules.” The
installation procedure for both is the same.
1. Remove the blank panel covering the CKd’s module bay by removing the
screws on either side of the panel. Save these screws, as they will be
needed for fastening the network module.
2. Inside the exposed module bay you should see the ribbon cable connector
on the amplifier’s circuit board. Note of the way the connector is keyed, and
position the ribbon cable to match. Insert the cable into the connector, with
the opposite end hanging out of the module bay.
3. Position the network module right side up. Connect the exposed end of the
ribbon cable to the connector on the module, again taking note of the
keying of the connectors.
4. Slide the module into the bay, and fasten it to the CKd’s chassis with the
screws removed in Step #1.
CKd Series Owners Manual v1e
Page
16
Содержание CKd Series
Страница 1: ...608 608 ...
Страница 27: ......