CKd Owner’s Manual
With two SPST momentary switches, one switch must be wired across the “On”
and “Com” pins, and the other switch must be wired across “Off” and “Com”
pins. When the first switch is depressed, it shorts the “On” and “Com” pins,
turning the amplifier on. Depressing the other switch will short the “Off” and
“Com” pins, turning the
CKd off. See the diagram below:
To STO In
of next amp
On
Com
Off
On
Off
SPST Momentary
Switches
Any number of CKd, Ci, CKi or CKS/V/X amplifiers can be daisy-chained
together for sequential turn-on. Wiring two amplifiers for STO is as simple as
connecting the “On,” “Com” and “Off” pins of the “STO Out” connector on the
first amplifier to the corresponding pins on the “STO In” connector on the
second amplifier. Repeating this wiring scheme with subsequent amplifiers
allows entire systems of CKd’s to be wired for STO.
STO connections are
optically isolated so
connecting amplifiers
from different AC feeds
will not create grounding
(hum) issues.
Amp 1
Amp 2
Amp 3
Amp 4