![Crescent SC430 53 B GO FULL PKG Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/crescent/sc430-53-b-go-full-pkg/sc430-53-b-go-full-pkg_operators-manual_2682845012.webp)
ENGLISH
INSTRUCTION FOR USE
Figure 5
Battery installation
6.
Disconnect the battery connector (9).
7.
Open the recovery tank lid (24) to check if the tank is empty, if not, empty it by the drain hose (15).
8.
Unscrew the squeegee knob (16) and remove the connector of sewage suction hose (11) to take down the
squeegee.
9.
Unscrew the screws of battery box cover (10) to remove it.
10.
Remove the connector that connect squeegee lifting (12) and squeegee bracket (19), place the squeegee lifting
to suitable place for battery installation.
11.
Place the sewage suction hose and drain hose to suitable place for not prevent battery installation. (A, Figure 6)
12.
Push the battery baffle block to inside of the machine battery box.
NOTE
When battery size less than the specified, to prevent battery movement, choose suitable battery baffle
block (B, Figure 6) to plug the battery.
Figure 6
14.
Use specialized tool (A, Figure 7) for batteries assembly.
15.
Assemble all the disassembled components along with opposite order.