![Crescent SC430 53 B GO FULL PKG Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/crescent/sc430-53-b-go-full-pkg/sc430-53-b-go-full-pkg_operators-manual_2682845011.webp)
ENGLISH
INSTRUCTION FOR USE
Never cover these symbols on the machine for any reason, replace it immediately if any damage.
INSTALLING AND SETTING OF NEW MACHINE BATTERY
WARNING!
The electric components of the machine can be seriously damaged if the batteries are either
improperly installed or connected.
The batteries must be installed by qualified personnel only. Set the battery charger (optional) according to the
battery type (WET or GEL/AGM).
NOTE
The machine requires two 12V batteries not exceeding the total size L
330 x W170 x H260 MM and
connecting according to Figure 4.
Figure 4
The machine can be operated in one of the following mode:
Without Batteries
1.
Buy appropriate batteries (See the Technical Data paragraph). For battery choice and installation, choose
qualified battery Retailers.
2.
When batteries are ready, set the machine and the battery charger (if equipped) according to the type of
batteries. (Refer to the installation and settings of batteries)
WET or GEL/AGM batteries are already installed and ready to be used
1.
Connect the battery connector (9) to the machine then turn on the power switch (45).
2.
If the green LED (42) is on, batteries are full charged for use. If the yellow or red LED (44 or 43) turns on, the
batteries must be charged (see the procedure in Maintenance chapter).
Machine setting
Set the electronic circuit board of the machine and battery charger (if equipped) according to battery types (WET or
GEL/AGM) following steps below:
1.
Make sure the connector (9) of the battery is disconnected. The factory setting is for GEL batteries. If the setting
correspond to the battery installation, go to step 7 directly. Otherwise, follow next steps 2~5.
2.
Take down the drain hose (15) from the clip.
3.
Unscrew the screws on control box cover (5), battery cover (10) and PCB bracket (A, Figure 5), then turn over
the PCBA to find the DIP switch (B, Figure 5) for setting battery type(WET or GEL).
4.
Turn the DIP switches to “WET” position for wet batteries installed.
5.
Perform steps 2, 3, 4 in the reverse order to recovery the machine.
8