INSTALLATION INSTRUCTIONS

C-AR SERIES 

http://lighting.cree.com/warranty      |     866.924.3645     

Fixture is equipped with universal volt driver 120-277V or a 347-

480V driver.  

NOTE:

 Make sure voltage range of fixture is compatible with 

supply voltage.

PHASE TO NEUTRAL WIRING 120/277/347V

1.  Connect supply ground to fixture ground (green) lead.
2.  Connect supply common to fixture neutral (white) lead.
3.  Connect supply Vin to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no wires 

are pinched.

PHASE TO PHASE WIRING 208/240/480V

1.  Connect supply ground to fixture ground (green) lead.
2.  Connect supply L1 (Hot) to fixture neutral (white) lead.
3.  Connect supply L2 (Hot) to fixture hot (black) lead.

Tuck all wires carefully into wiring chamber ensuring that no wires 
are pinched.

FIXTURE WIRING

NOTE: 

Fixture is only UL listed for downlight orientation.

NOTE:

 Use this fixture installation sheet for installing. DO NOT refer to 

the mounting accessory sheet for installing.
1. 

Remove the (4) bolts and sealing washers holding the fixture back 

box to the housing using a 9/16" socket.

2.  Disconnect the 2 halves of the quick disconnect on the housing 

cord to allow the back box to be separated from the housing.

3. 

Install gasket on upper fitter by aligning the (2) holes in the gasket 
with the (2) threaded holes in the upper fitter.

4. 

Align (2) threaded holes in the upper fitter with the (2) bolt holes in 
the fixture back box.

5. 

Fasten upper fitter to the fixture back box using the (2) bolts and 
lock washers supplied with the fitter. Tighten bolts to 132 in-lbs 

 

(15 N•m)

6. 

Remove splice compartment cover from upper fitter by removing 

(2) screws on cover.

7.  Reconnect 2 ends of quick disconnect which were disconnected 

in Step 2.

8. 

Route fixture wires through center hole in the wall of the fixture 
back box and into the fitter wiring chamber.

9. 

Reinstall the fixture back box onto the fixture with the (4) bolts and 

sealing washers that were removed in Step 1. Tighten bolts to  
19 ft-lbs. (25 N•m). Be careful not to pinch wires.

10.  Strain relief is required for electrical connections on 2" adjustable 

fitter mounts at heights of 25' (7.6 m) and above. Tie a knot in 
the supply wires above the supply wire entry hole in the fitter wire 

chamber to reduce the strain on the connections. Make sure the 
knot will not slip through the hole.

11. 

Slip the lower fitter over 2-3/8" (60 mm) o.d. heavy wall pipe or 

tenon and securely tighten the two Allen head set screws with a 
3/16" Allen wrench to 140 in-lbs (16 N•m).

12. 

Loosen (do not remove) 3/8" bolt in fitter wiring chamber and tilt 
fixture to desired angle. Tighten 3/8" bolt to 19 ft-lbs (25 

N•m).

13.  See 

Fixture Wiring

 section for electrical connections.

14. 

If photocell accessory is used, locate it in the cover of the fixture 

wiring chamber. See photocell installation sheet for details.

15. 

Replace fitter wiring chamber cover and tighten (2) screws that 

were removed in Step 6.

NOTE: 

Fixture is only UL listed for downlight orientation.

NOTE:

 Strain relief is required for electrical connections at height of 25' 

(7.6 m) and above. Knot the supply wires from the pole with the fixture 

cord inside the pole.

NOTE:

 Us the fixture installation sheet for installing DO NOT refer to 

mounting accessory sheet for installing.
1.  Us template 1 on the last page for dimensions on pole drilling if 

pole is not predrilled. 

NOTE: Template is not to scale.

2. 

Remove the (4) bolts and sealing washers holding the fixture back 

box to the housing using a 9/16” socket.

3.  Disconnect the 2 halves of the quick disconnect on the housing 

cord to allow the back box to be separated from the housing.

4.  Insert end of cord supplied with mounting arm through cord grip 

so that the wires extend from the threaded end of the cord grip by 

approximately 4". Tighten cord grip firmly to cord.

5.  Remove nut from cord grip. Pass threaded end of cord grip 

through wall of the back box from outside to inside of box. Make 
sure gasket for cord grip is on outside of back box.

6.  Tighten nut on threaded end of cord grip to secure cord grip to 

back box. Do not overtighten nut to prevent damage to threads.

2" (51 mm) ADJUSTABLE FITTER MOUNTING

DIRECT MOUNTING

7.  Screw threaded rods through smaller holes in pole into backing 

plate inside pole until non-threaded section of rods contact 
backing plate. See 

Figure 3.

8.  Feed cord exiting outside of back box through arm extrusion and 

into pole. Slide extrusion over threaded rods so that the rods are 
positioned in extrusion channels.

9.  Align mounting holes of back box with exposed ends of threaded 

rods and push back box flushed against extrusion.

10.  Install sealing washers and nuts onto threaded rods inside back 

box. See 

Figure 3.

11.  Torque hex nuts to 132 in-lbs (15 N•m).
12. 

Lift fixture close to back box and attach loop in aircraft cable from 
back box to c-hook on fixture to support fixture.

13.  Reconnect 2 ends of quick disconnect which were disconnected 

in Step 3.

14. 

Connect cord green wire to fixture ground wire (ground).
Connect cord white wire to fixture common wire (white).
Connect cord black wire to fixture voltage wire (black).

15. 

Reinstall the fixture back box onto the fixture with the (4) bolts and 

sealing washers that were removed in Step 2. Tighten bolts to  
19 ft-lbs. (25 N•m).

16.  Make wire connections inside pole per 

Fixture Wiring

 section.

17.  Install pole cap.

FIGURE 3

Back Box

Cord Grip

Hex Nut

Sealing 

Washer

Threaded 

Rod

Cord

Содержание C-AR Series

Страница 1: ...t 2 Disconnect the 2 halves of the quick disconnect on the housing cord to allow the back box to be separated from the housing 3 Attach U bracket to fixture back box as shown in Figure 1 Make sure sealing washers are under bolt heads U BRACKET MOUNTING 4 Pass bolts from inside of fixture back box through back box and U bracket 5 Slide 2 lock washers over bolts 6 Secure U bracket to back box with 2...

Страница 2: ... and tilt fixture to desired angle Tighten 3 8 bolt to 19 ft lbs 25 N m 13 See Fixture Wiring section for electrical connections 14 If photocell accessory is used locate it in the cover of the fixture wiring chamber See photocell installation sheet for details 15 Replace fitter wiring chamber cover and tighten 2 screws that were removed in Step 6 NOTE Fixture is only UL listed for downlight orient...

Страница 3: ...n against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radi...

Страница 4: ...soporte en U a la caja posterior de la luminaria de la forma que se muestra en la Figura 1 Asegúrese de colocar arandelas de sello debajo de las cabezas de los pernos 4 Pase los pernos desde el interior de la caja trasera de la luminaria a través de la caja trasera y el soporte en U MONTAJE DEL SOPORTE en U 5 Deslice las 2 arandelas de seguridad sobre los pernos 6 Fije el soporte en U a la caja tr...

Страница 5: ...9 ft lb 25 N m 13 Consulte la sección Cableado de la luminaria para ver las conexiones eléctricas 14 Si se usa el accesorio de fotocelda ubíquelo en la tapa de la caja de conexiones de la luminaria Consulte los detalles en la hoja de instalación de la fotocelda 15 Vuelva a colocar la tapa de la caja de conexiones y apriete los 2 tornillos que retiró en el paso 6 NOTA La luminaria está listada en U...

Страница 6: ... a fin de brindar una protección razonable contra interferencias perjudiciales en instalaciones residenciales Este equipo genera usa y puede irradiar energía de radiofrecuencia Si no se instala y usa de acuerdo con las instrucciones puede causar interferencias perjudiciales para las comunicaciones radiales Sin embargo no existe garantía de que no se produzca interferencia en una aplicación en part...

Страница 7: ...s les têtes d écrous 4 Passez les boulons de l intérieur de la partie arrière du luminaire à travers cette dernière et le support en U MONTAGE DU SUPPORT EN U 5 Glissez 2 rondelles de blocage sur les boulons 6 Fixez le support en U à la partie arrière avec 2 écrous de 7 9 mm 5 16 po Serrez les écrous à 15 Nm 132 po lb 7 Insérez l extrémité du cordon fourni avec la trousse du support en U à travers...

Страница 8: ...n de 9 5 mm 3 8 po à 25 Nm 19 pi lb 13 Voyez la section Câblage du luminaire pour les connexions électriques 14 Si une photocellule est utilisée comme accessoire placez la dans le couvercle de la chambre de câblage du luminaire Consultez la fiche d installation d une photocellule pour plus de détails 15 Replacez le couvercle de la chambre de câblage du montant et serrez les 2 vis retirées à l étap...

Страница 9: ...nable contre les interférences nuisibles dans une installation résidentielle Cet équipement génère utilise et peut émettre de l énergie de radiofréquence et si non installé et utilisé selon les instructions il peut causer une interférence nuisible aux radiocommunications Par contre il n existe aucune garantie que les interférences ne se produiront pas dans une installation en particulier Si cet éq...

Отзывы: