background image

6 of 8

LPN00644X0007A0_A

SECTION 3:  

OFF GRID MOUNTING (HARD CEILING) - 
INDIVIDUAL RECESSED MOUNTING

CAUTION:

 Ceiling contractor must provide an uninterrupted, 

continuous rough opening. Dimensions of opening should be 

determined using 

Figure 3 on page 3 and Figure 9.

CAUTION:

 Luminaires should be secured to structure above 

using customer supplied threaded rods to support weight of 
luminaire.

STEP 1: 

Remove lens and LED/reflector tray and  set aside in order 
of run placement for reinstalling later. To remove lens, 
carefully slide a plastic card or putty knife between the lens 
and extrusion towards the end of the luminaire. Using the 
plastic card or putty knife, push the lens inward until the 
lens come free. After removing the lens, remove the Philips 
head reflector screws, remove the LED Reflector Tray, and 
disconnect the LED harness. Set lens and LED Reflector tray 
aside. See 

Figure 2 and 8.

STEP 2:

Using one of the 7/8" dia. holes on the end of the fixture, 
install conduit connector. See 

Figure 8.

 

STEP 3:

Install fixture from below into ceiling opening. Attach 

customer supplied threaded rods to luminaire through 5/8" 
mounting holes located on the top of the housing and to the 
structure above as shown in 

Figure 8

. Confirm that fixture is 

pulled up firm to ceiling line.

STEP 4:

Make electrical connections per Section 5 “Electrical 

Connections” to leads in wiring compartment. 

STEP 5:

Reconnect LED harness. Replace LED trays and lens that 

was removed in Step 1 above, ensure that no wires are 

pinched.

STEP 6:

For Hard Ceiling, Overlap Flange Only:
Fill in Sheet Rock mud over tapered extruded flange until 
smooth. See 

Figure 10.

9

4.25"

Ceiling opening width 

for Flangeless

3.37"

Ceiling opening width 

overlapping flange 

8

Flexible Conduit 

Supplied By Others

Threaded Support Rods Supplied By Others

Support Nut 

Supplied By Others

LED Tray

Lens

#10-18 X 1/4”

Phillips Head Screws

Sheetrock Mud

Supplied By Others

Sheetrock Mud

Supplied By Others

Threaded Support Rod

Supplied by Others

10

Содержание Stylus Series

Страница 1: ...icien qualifié 3 SUITABLE FOR CONTINUOUS ROW MOUNTING PEUT ÊTRE MONTÉ EN RANGÉE CONTINUE 4 Suitable for Damp Locations Convient aux emplacements humides 5 MIN 90C SUPPLY CONDUCTORS LES FILS D ALIMENTATION 90C MIN 6 INHERENTLY PROTECTED 7 TYPE IC VAPOR BARRIER MUST BE SUITABLE FOR 90C TYPE IC LE PARE VAPEUR DOIT CONVENIR POUR 90 C PROTECTION INHERENTE 8 Make sure the equipment is properly grounded ...

Страница 2: ...ire Using the plastic card or putty knife push the lens inward until the lens comes free See Figure 1 and 2 STEP 2 After removing the lens remove the Philips head reflector screws remove the LED Reflector Tray and disconnect the LED harness Set lens and LED Reflector tray aside See Figure 1 STEP 3 Attach customer supplied support cables to luminaire and structure above as shown in Figure 1 STEP 4 ...

Страница 3: ...alled with threaded rod to structure above by others and should be installed accordance with these instructions Plugged holes for threaded rod attachment are located 4in from both ends of each luminaire 23 25 0 19 Endcap Thickness 0 19 47 25 71 25 95 25 119 25 143 25 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness 0 19 Endcap Thickness ...

Страница 4: ... 7 In order to install the end cap on the male end of the luminaire replace the male joiner bracket with the female joiner bracket and remove the alignment pins See Figure 4 and 6 STEP 3 Lay the first luminaire Right Hand End of the Row into the grid per Figure 7 grid requirements STEP 4 Position second luminaire in row such that it aligns with joint end male end of first luminaire Attach using cu...

Страница 5: ...7 8 7 8 8 9 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 50 52 54 56 58 60 26 28 30 32 34 36 38 40 42 44 46 48 62 64 66 68 70 72 Trim Length for Endcaps in For On Grid Mounting ONLY Continous Row Length in End Cap to End Cap LUMINAIRE ROW LAYOUT EXAMPLE OF A THREE UNIT 20 24 CAN BE MOUNTED IN OTHER CONFIGURATIONS 7 86 7 8 86 7 8 38 7 8 237 1 16 End Cap to End Cap 236 1 16 Aperture 284...

Страница 6: ...8 STEP 2 Using one of the 7 8 dia holes on the end of the fixture install conduit connector See Figure 8 STEP 3 Install fixture from below into ceiling opening Attach customer supplied threaded rods to luminaire through 5 8 mounting holes located on the top of the housing and to the structure above as shown in Figure 8 Confirm that fixture is pulled up firm to ceiling line STEP 4 Make electrical c...

Страница 7: ...s located on the top of the housing and to the structure above as shown in Figure 7 and 8 Confirm that fixture is pulled up firm to ceiling line STEP 3 Position second luminaire in row such that it aligns with joint end male end of first luminaire Attach customer supplied supports to fixture through mounting holes located on the top of the housing and to the structure above as shown in Figure 11 C...

Страница 8: ...supply dimming negative lead If dimming is not being used ensure to cap off the grey lead GREEN LINE BLACK GROUND GREEN NEUTRAL WHITE DIM GREY DIM VIOLET VIOLET GREY CORD SUPPLY WIRING LUMINAIRE NEUTRAL OR HOT 2 LINE OR HOT 1 FCC NOTICE CAUTION Changes or modifications not expressly approved could void your authority to use this equipment This device complies with part 15 of the FCC Rules Operatio...

Отзывы: