CRE I4GEN Скачать руководство пользователя страница 3

TECHNICAL DOCUMENTATION

3

A56V1_90020_D_EN

Introduction

Caution Safety protections

Operate the product according to the correct installation steps and with great care to make sure
safety and comfort using experience. Please refer to the following safety instruction guide to avoid
danger of electric shock or fire. Abide by the previous safety instruction guide to use and maintain
the product and the hard disk to make sure of safe operating environment.

·

Please follow the instruction manual for operation guide.

·

The appropriate operating temperature ranges from -10...60°C.

·

The operation humidity for this product is 5% to 80% RH.

·

To avoid high temperature, please DO NOT overload the maximum power of the external power
supply while the system is consuming high voltage. Be aware of the maximum temperature
allowance of the power supply.

·

See to it that the product is not working near the water.

·

Always unplug power cable and other hardware cables from the system before cleaning.

·

Apply only dry cloth for cleansing the product.

·

Make sure that there is no heat source nearby when the product is working.

·

Make sure that the thermal louver of the product is not blocked.

·

Make sure to remove the power plug from the product when there is a thunder storm.

·

Please remove the power plug from the product when you are not going to use the product for a long
time.

·

Make sure to set up or use the product on a stable surface.

·

Make sure not to drop the product or strike it by any means.

·

Make sure not to move the product when the power is on.

·

Make sure not to step on the power cables and other cables or rest anything in them.Be sure to
ground yourself to prevent static charge when installing any internal components. Use a grounding
wrist strap and place all electronic components in any static-shielded devices. Most electronic
components are sensitive to static electrical charge.

·

Disconnect the power cord from the Panel PC unit prior to any installation. Be sure both the system
and all external devices are turned off. Sudden surge of power could ruin sensitive components.
Make sure the Panel PC unit is properly grounded. unit

·

Do not open the system's back cover. If opening the cover for maintenance is a must, only a trained
technician is allowed to do so. Integrated circuits on computer boards are sensitive to static
electricity. To avoid damaging chips from electrostatic discharge, observe the following precautions:

·

Before handling a board or integrated circuit, touch an unpainted portion of the system unit chassis
for a few seconds. This will help to discharge any static electricity on human body.

·

When handling boards and components, wear a grounding wrist strap available from most electronic
component stores.

·

Please contact qualified technician for maintenance or repair.

·

Use only accessories and parts that are made by the qualified manufacturer.

Содержание I4GEN

Страница 1: ......

Страница 2: ...ction 12 Communication 13 Pre requisite 13 Login Connection 14 Functioning 17 Interface 17 Graphic objects 21 Numerical display 21 Numerical display by variable number 21 Boolean display LED 21 Bargra...

Страница 3: ...he product for a long time Make sure to set up or use the product on a stable surface Make sure not to drop the product or strike it by any means Make sure not to move the product when the power is on...

Страница 4: ...ill not be liable for any indirect special incidental or consequential damages including damages for loss of profit loss of business loss of use of data interruption of business and the like Products...

Страница 5: ...m when external antennas are connected Different computers in the house can build wireless connections through the Mini TOPS Total Operations Processing System and take necessary data from it thus red...

Страница 6: ...M Resolution 1280 x 800 60Hz Viewing Angle H V 170o 170o Pixel Pitch 0 1695 x 0 1695 mm Aspect Ratio 16 10 Contrast Ratio 800 1 Response Time 30 ms Touch Screen Type Projected capacitive type Active R...

Страница 7: ...Not used USB 3 0 Port 4 To connect USB keyboard mouse or other devices compatible with USB specification USB 3 0 ports supports up to 5Gbps data transfer rate RJ 45 LAN Port 2 This connector is stand...

Страница 8: ...Gen can be used as a power plant display if connected on an Ethernet HUB accessing to each controller with the Modbus TCP network In SCADA mode the direct display of any of the controller is available...

Страница 9: ...tched Make sure the fix part is installed in the way the photo shows with protruding tips upwards 2 The models that support this fixing mode have pairs of slots reserved on both sides of the system Us...

Страница 10: ...e end of USB device you wish to connect to USB port of the chassis as the photo shows 4 Insert Part B into corresponding slot of the Part A and choose the installing length by adjusting the screw hole...

Страница 11: ...e disconnect the AC DC adapter wires from the connector and connect the battery wires to the connector instead 9 36VDC input Euro terminal power jack 1 Turn off your power supply 2 Connect the male su...

Страница 12: ...h Connect the Ethernet port RJ45 LAN labeled module of the i4Gen on one of the switch s Ethernet ports Connect the Ethernet port of the controller on one of the switch s Ethernet ports You can connect...

Страница 13: ...er The controller network configuration can be done from the controller front panel or controller website or via CRE Config software If the i4Gen and the controller are connected directly the network...

Страница 14: ...ts Menu 0 None None Display and manual button 1 1 User settings All Menus 2 CRE Technology distributor s reserved Advanced settings All Menus To connect to a module you have to fill the following info...

Страница 15: ...ging the Password field and pressing the button Passwords are the same as those used to connect directly to the module via its front panel or embedded website It is possible to disconnect by pressing...

Страница 16: ...TECHNICAL DOCUMENTATION 16 A56V1_90020_D_EN During connection re connection attempts the button is replaced by a button to manually cancel the attempts...

Страница 17: ...ION 17 A56V1_90020_D_EN Functioning Interface The interface of the i4Gen allows to replace the front panel of CRE Technology modules and to offer a better ergonomics in order to facilitate the supervi...

Страница 18: ...nnection Login menu Settings menu Home Back to home page INDICATORS Alarm Blinking unacknowledged alarm Static alarm acknowledged and in progress Fault Blinking unacknowledged fault Static fault ackno...

Страница 19: ...mode colored in theme color when active TEST mode colored in theme color when active MANUAL mode colored in theme color when active Give access to additional buttons for manual frequency voltage contr...

Страница 20: ...ervision mode the footer gives access to Control buttons of the controller Specific information on the generator number engine status power status Synoptic of the installation Note When the i4Gen is o...

Страница 21: ...e number Composition label modifiable address field value unit This is the graphic object used in the info page of the i4Gen It allows you to search for a controller variable by entering its address i...

Страница 22: ...ault It is possible to display up to 2 max and 2 min protection thresholds per bargraph If none protection is configured no threshold will be displayed on the bargraph Bargraph states Nothing to repor...

Страница 23: ...s the graphic object used for electrical measures and whose representation of the measure with respect to a min and a max is important The gauge fill part corresponds to the value of the measurement w...

Страница 24: ...s that change according to the state of the associated protections in each of these pages Engine 1 Indicates the presence of a water temperature alarm fault 2 Indicates the presence of a battery volta...

Страница 25: ...d to allow the circuit breaker to close 2 In the bargraphs located in the center of the synchroscope the cursor position represents the frequency voltage difference between the generator and the mains...

Страница 26: ...26 A56V1_90020_D_EN Popup i4Gen can display popup windows to give information to the user There is three type of popup Notice display an information message Warning display a warning message Error di...

Страница 27: ...isualization The fault alarm history is displayed as a table from the most recent alarm fault to older one Each line in the history shows the following information 1 Date of appearance of the event 2...

Страница 28: ...e been acknowledged the alarm fault panel is a fixed color Filters Several filters are available to filter the display of the alarm fault table These filters can be combined vertically see image below...

Страница 29: ...to display the About page This page displays 1 An i4Gen section with the software version client and server 2 A controller section with Type of controller connected to the i4Gen The firmware version o...

Страница 30: ...TION 30 A56V1_90020_D_EN Home page Press home icon to open home page The home page is a dynamic page whose content changes according to the power state variable and the states of the generator and mai...

Страница 31: ...the generator 3 Bus Mains Display of electrical measures of the bus mains 4 Engine Display of engine measures and J1939 measures if a J1939 manufacturer has been configured 5 Synchro Display of synchr...

Страница 32: ...he number of the variable you want to change in the Variable number input field 2 Enter the value you want to write in the Value input field 3 Press Send button to send the change to the controller A...

Страница 33: ...ter of the configuration section This function is useful when parameters have been temporarily modified by Modbus TCP modification of info variables from i4Gen in password level 0 modification of para...

Страница 34: ...ings pages see image below Language The Language page has two buttons flags French to set to French the application language English to set to English the application language Note In connected mode a...

Страница 35: ...TECHNICAL DOCUMENTATION 35 A56V1_90020_D_EN Theme The Theme page allows you to change the theme color of the application corresponding to the different controllers of the CRE Technology Compact range...

Страница 36: ...the i4Gen is connected to an external screen via an HDMI port it is possible to duplicate the i4Gen display on the external display by pressing the duplicate button Note Dysfunction this function is n...

Страница 37: ...te time with the one of the i4Gen 1 Date press on the editable field to display a calendar and set up the i4Gen date 2 Time press on the editable field to set up the i4Gen time 3 Confirm Press this bu...

Страница 38: ...preferences page then the i4Gen will attempt to connect to that address Switch connect This parameter enables disables the switch connect function from the power plant supervision page If you have a...

Страница 39: ...TECHNICAL DOCUMENTATION 39 A56V1_90020_D_EN...

Страница 40: ...s of a controller must correspond to its generator number ex GE number 2 IP address X X X 2 Example of configuration with 3 controllers Controller 1 o Number of GE 1 o IP address 192 168 11 1 Controll...

Страница 41: ...ation DHCP Configuration automatic If the i4Gen is connected to a DHCP server you can enable the DHCP setting to automatically assign an IP address to the i4Gen Manual Setup To manually configure the...

Страница 42: ...Refresh button to refresh the i4Gen USB device display 2 Browse on your USB stick via the folder tree and select the update archive 3 Press the Update Application button to check the contents of the...

Страница 43: ...is updated This will be lost when the i4Gen restarts The block on the right side corresponds to the saved user configuration This configuration will be taken into account when restarting the i4Gen Th...

Страница 44: ...TECHNICAL DOCUMENTATION 44 A56V1_90020_D_EN Dimensions...

Страница 45: ...TECHNICAL DOCUMENTATION 45 A56V1_90020_D_EN Note Measure unit mm...

Отзывы: