6840070
Page 11
August, 2005
Café VII
®
Setup
FASTEN AND SEAL
Before beginning this procedure verify both clearance and accessibility from
beneath the counter top.
Field Supplied Parts
Four (4) 5/16" thread-cutting screws.
Four (4) 5/16" flat washers.
Correct Screw Length
With the washer installed the remaing thread will equal the counter thickness
plus 7/16".
Layout the machine location and mark locations of the four holes. Drill using a
1/2" bit. Secure the unit to the counter top with the thread-cuttng screws. Do not
overtighten, or the plastic nuts in the machine base may be stripped. (It may be
easier to connect the water line before securing the unit to the counter top.)
INSTALL AND SEAL
Before beginning this procedure verify both clearance and accessibility from
beneath the counter top. This option allows the use of a large waste grounds pail
located under the counter top. Remove the floor liner from the bottom of the
unit. Take out the two screws holding the cover plate. Cut a hole corresponding
to the opening in the bottom of the unit in the floor liner.
Field Supplied Parts
Four (4) 5/16" thread-cutting screws.
Four (4) 5/16" flat washers.
Correct Screw Length
With the washer installed the remaing thread will equal the counter thickness
plus 7/16".
Layout the machine location; then mark locations of the four fastening holes, and
a 3
3
/
4
" by 6
3
/
4
" cutout. Drill the holes using a 1/2" bit and make the cutout.
Secure the unit to the counter top with the thread-cuttng screws. Do not
overtighten, or the plastic nuts in the machine base may be stripped. (It may be
easier to connect the water line before securing the unit to the counter top.)
Содержание Cafe VII
Страница 2: ......
Страница 6: ...Page iv 6840069 July 2001 Café VII Setup Notes ...
Страница 10: ...Page 4 6840070 August 2005 Café VII Setup EXTERNAL VIEW ...
Страница 12: ...Page 6 6840070 August 2005 Café VII Setup INTERNAL VIEW 684p0007 1 2 3 4 5 6 7 8 7 7 9 7 7 7 7 10 11 12 13 ...
Страница 19: ...6840070 Page 13 August 2005 Café VII Setup HYDROLIFE BRAND INSTALL WATER FILTER ...
Страница 20: ...Page 14 6840070 August 2005 Café VII Setup EVERPURE BRAND ...
Страница 29: ...6840070 Page 23 August 2005 Café VII Setup ...
Страница 75: ...6840070 Page A1 August 2005 Café VII Setup APPENDIX A FACTORY DEFAULT TIMES ...