Please  Read  This  Before  Installing  Or  Operating  Pump. 
This  information  is  provided  for 

SAFETY  and  to  PREVENT 

EQUIPMENT  PROBLEMS

.  To  help  recognize  this  information, 

observe the following symbols:

IMPORTANT!

  Warns  about  hazards  that  can  result 

in  personal  injury  or  Indicates  factors  concerned  with 
assembly,  installation,  operation,  or  maintenance  which 
could  result  in  damage  to  the  machine  or  equipment  if 
ignored.

CAUTION  !

  Warns  about  hazards  that  can  or  will  cause  minor 

personal injury or property damage if ignored. Used with symbols 
below.

WARNING !

  Warns about hazards that can or will cause serious 

personal injury, death, or major property damage if ignored. Used 
with symbols below.

Only  qualifi ed  personnel  should  install,  operate  and  repair 
pump. Any  wiring  of  pumps  should  be  performed  by  a  qualifi ed 
electrician.  

WARNING ! -

 To reduce risk of electrical shock, pumps 

and  control  panels  must  be  properly  grounded  in 
accordance with the National Electric Code (NEC) or the 
Canadian Electrical Code (CEC) and all applicable state, 
province, local codes and ordinances. 

WARNING! -

 To reduce risk of electrical shock, always 

disconnect  the  pump  from  the  power  source  before 
handling or servicing. Lock out power and tag.

Prevent  large  articles  of  clothing,  large  amounts  of  chemicals, 
other materials or substances such as are uncommon in domestic 
sewage from entering the system.

During  power  black-outs,  minimize  water  consumption  at  the 
home(s) to prevent sewage from backing up into the house.

Always keep the shut-off  valve completely open when system is 
in operation (unless advised otherwise by the proper authorities). 
Before  removing  the  pump  from  the  basin,  be  sure  to  close  the 
shut-off  valve. (This prevents backfl ow from the pressure sewer.)

Keep the control panel locked or confi ned to prevent unauthorized 
access to it.

If the pump is idle for long periods of time, it is advisable to start the 
pump occasionally by adding water to the basin.

CAUTION! 

Pumps build up heat and pressure 

during  operation-allow  time  for  pumps  to  cool 
before handling or servicing. 

WARNING!

  - 

DO  NOT

  pump  hazardous  materials 

(fl ammable, caustic, etc.) unless the pump is specifi cally 
designed and designated to handle them.

Do  not  block  or  restrict  discharge  hose,  as  discharge  hose  may 
whip under pressure. 

WARNING!  -  DO  NOT

  wear  loose  clothing  that  may 

become entangled in the impeller or other moving parts. 

WARNING!  - 

Keep  clear  of  suction  and  discharge 

openings.  DO  NOT  insert  fi ngers  in  pump  with  power 
connected.

Make sure lifting handles are securely fastened each time before 
lifting. Do not operate pump without safety devices in place. Always 
replace safety devices that have been removed during service or 
repair.

Do  not  exceed  manufacturers  recommendation  for  maximum 
performance, as this could cause the motor to overheat.

Secure  the  pump  in  its  operating  position  so  it  can  not  tip  over, 
fall or slide.

Cable  should  be  protected  at  all  times  to  avoid  punctures,  cut, 
bruises and abrasions - inspect frequently. 

Never handle connected power cords with wet hands.

To reduce risk of electrical shock, all wiring and junction 
connections  should  be  made  per  the  NEC  or  CEC  and 
applicable state or province and local codes. Requirements 
may vary depending on usage and location.

Submersible Pumps are not approved for use in swimming 
pools,  recreational  water  installations,  decorative 
fountains  or  any  installation  where  human  contact  with 
the pumped fl uid is common.

Do  not  remove  cord  and  strain  relief.  Do  not  connect  conduit  to 
pump. 

Products  Returned  Must  Be  Cleaned,  Sanitized,  Or 
Decontaminated  As  Necessary  Prior  To  Shipment,  To 
Insure That Employees Will Not Be Exposed To Health 
Hazards In Handling Said Material. All Applicable Laws 
And Regulations Shall Apply.
 
Bronze/brass and bronze/brass fi tted pumps may contain 
lead levels higher than considered safe for potable water 
systems.  Lead  is  known  to  cause  cancer  and  birth 
defects or other reproductive harm. Various government 
agencies  have  determined  that  leaded  copper  alloys 
should  not  be  used  in  potable  water  applications.  For 
non-leaded copper alloy materials of construction, please 
contact factory. 

IMPORTANT! -

 Crane Pumps & Systems, Inc. is not 

responsible for losses, injury, or death resulting from a 
failure to observe these safety precautions, misuse or 
abuse of pumps or equipment.

A pump that is intended to pump sewage or effl  uent 
shall be installed in a tank that is vented in accordance 
with local plumbing codes and is not classifi ed as 
hazardous in accordance with the National Electrical 
Code, ANSI/NFPA 70 unless it is specifi cally marked for 
such use.

SAFETY FIRST!

Hazardous 

fl

 uids can 

cause 

fi

 re or explo-

sions, burnes or death 
could result.

Extremely hot - Severe 
burnes can occur on contact.

Biohazard can cause 
serious personal injury.

Hazardous 

fl

 uids can Hazard-

ous pressure, eruptions 
or explosions could cause 
personal injury or property 
damage.

Rotating machinery
Amputation or severe 
laceration can result.

Hazardous voltage can 
shock, burn or cause death.

Other brand and product names are trademarks or registered trademarks of their respective holders.
® Barnes is a registered trademark of Crane Pumps & Systems Inc.
2016 

 

 

 

 

 

 

 

 

 

 

Alteration Rights Reserved

Содержание Barnes PGPT Series

Страница 1: ...t product improvement program product changes may occur As such Crane Pumps Systems reserves the right to change product without prior written notification 420 Third Street 83 West Drive Bramton Piqua Ohio 45356 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 140868 Rev B Series PGPT 1 HP 3450 RPM 60 Hz PUMP ONLY ...

Страница 2: ...ting handles are securely fastened each time before lifting Do not operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Do not exceed manufacturers recommendation for maximum performance as this could cause the motor to overheat Secure the pump in its operating position so it can not tip over fall or slide Cable should be protec...

Страница 3: ...he Barnes grinder pump station The basin collects all wastewater from the house The solids in the sewage are then ground to a small size suitable for pumping in the slurry The grinder pump generates sufficient pressure to pump this slurry from your home to the wastewater plant Power Failure Your grinder pump cannot dispose of wastewater or provide an alarm signal without electrical power If electric...

Страница 4: ...INGS Buna N HARDWARE 300 Series Stainless Steel PAINT Air Dry Enamel SEAL Design Single Mechanical Material Rotating Face Silicon Carbide Stationary Face Silicon Carbide Elastomer Buna N Hardware 300 Series Stainless CORD ENTRY Custom Molded Quick Connect for Sealing with Strain Relief CORD Type 12 5 CSA UL Approved SOW SPEED 3450 RPM 60Hz UPPER BEARING Design Single Row Ball Oil Lubricated Load R...

Страница 5: ...RT PGPT1022C 1 240 1 K 12 5 35 0 12 5 SOW 71 18 VARIES 1 5 3 3 Winding Resistance 5 measured from terminal block Pump rated for operation at 10 voltage at motor For 3 Phase models Temperature Sensor Cord is 14 3 SOW 0 55 14mm 02 51mm O D Cord shipped separately Recommended Breaker Sizes Pump Model HP Phase Volts Breaker Size All PGPT Models 1 1 240 15 Amp ...

Страница 6: ... number as well as other information The start up form located in the back of this manual contains a place to record this data The information should be recorded now so the pump does not have to be pulled again later The start up form can be left in the control panel until station start up is completed later FIGURE 1 ...

Страница 7: ...r and placed in a temperature controlled storage area 3 Before placing pump into service pump should be brought to operational temperature range Excessive or direct heating or cooling should NOT be used OPERATION TEMPERATURE RANGE 35ºF 2ºC to 104ºF 40ºC SERVICE CENTERS For the location of the nearest Barnes Service Center check your Barnes representative or Crane Pumps Systems Inc Service Departme...

Страница 8: ...housing bore aligning alignment mark with hole in terminal block see Figures 3 4 Tighten bolts on compression flange until flush with motor housing Pump Power Large Pin Level Control Small Pin Level control cord has molded fitting at both ends of the cord Install one end to the Pump and the other end to the Level Control FIGURE 3 PGPT1022C FIGURE 4 Automatic Pumps PGPT1022C ...

Страница 9: ...9 Single phase 240 Volt AC 60Hz 12 5 SOW FIGURE 5 Wiring Harness Item 54 on Figure 8 ...

Страница 10: ...allation and freedom of operation 7 Open valve 8 Check cutter for freedom of operation security and condition Clean cutter and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Remove examine for damage Replace pump stator if required 11 Repair fixtures as required to eli...

Страница 11: ...11 FIGURE 6 ...

Страница 12: ...18 1 095368 Seal Tetra TS33 261 Buna Buna 20 2 109031 Plug Cap Poly CCF 2 25 21 1 112422 Anti Siphon Gasket Assembly Various 22 1 105377B Cover Valve Anti Siphon Various 23 3 1 523 1 Screw HXHD 1 4 20 75 300 SS 24 1 138979 Elbow Fixed Discharge Class 30 CI 25 1 625 01558 O Ring 223 Buna N 1 609 I D 26 1 138884 Valve Body Fixed Core 27 17 026322 Washer Lock 5 16 316 SS 28 3 2 23030 50 SHCS 5 16 18 ...

Страница 13: ...PXVW EH VLJQHG E RXU DXWKRUL HG UHSUHVHQWDWLYH XH WR LQDFFXUDFLHV LQ HOG WHVWLQJ LI D FRQÀ LFW DULVHV EHWZHHQ WKH UHVXOWV RI HOG WHVWLQJ FRQGXFWHG E RU IRU XVHU DQG ODERUDWRU WHVWV FRUUHFWHG IRU HOG SHUIRUPDQFH WKH ODWWHU VKDOO FRQWURO 5 200 1 7 216 25 63 33 7 216 25 7 26 5 68 7 1 520 6 67 06 1 6 6 1 9 8 7 216 21 8 7 6 21 285 67 9 3 5 1 1 38 6 1 8675 1 250 7 21 68 5 200 1 7 216 2 127 2167 787 55 1...

Страница 14: ...nt To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps...

Страница 15: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ___________________ Do protection devices comply with pump and motor Amp rating YES___ NO___ Are all electrical and panel entry connections tight YES___ NO___ Is the interior of the panel dry YES___ NO___ Liquid ...

Страница 16: ... OHYHO FRQWUROV LQVWDOOHG DZD IURP WXUEXOHQFH 6BBB 12BBB V OHYHO FRQWURO RSHUDWLQJ SURSHUO 6BBB 12BBB V SXPS IXOO VXEPHUJHG GXULQJ RSHUDWLRQ 6BBB 12BBB ROORZ XS RUUHFWLYH FWLRQ 5HTXLUHG 6BBB 12BBB GGLWLRQDO RPPHQWV BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB...

Отзывы: