background image

Limited Warranty

We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects
in material and workmanship under normal use and service for the following time periods, when installed and maintained in
accordance with our instructions. 
Pump Products: One (1) year from date of installation or (24) twenty-four months from date of shipment, whichever occurs
first. Cleaning Products: Twelve (12) months from date of installation or eighteen (18) months from date of shipment, whichever
occurs first. As used herein, "the ultimate consumer" is defined as the purchaser who first uses the product after its initial
installation or, in the case of product designed for non permanent installation, the first owner who used the product. It is the
purchaser’s or any sub-vendee’s obligation to make known to the ultimate consumer the terms and conditions of this warranty.
This warranty gives you specific legal rights, and there may also be other rights which vary from state to state. In the event
the product is covered by the Federal Consumer Product Warranties Law (1) the duration of any implied warranties associated
with the product by virtue of said law is limited to the same duration as stated herein, (2) this warranty is a LIMITED
WARRANTY, and (3) no claims of any nature whatsoever shall be made against us, until the ultimate consumer, his successor,
or assigns, notifies us in writing of the defect, and delivers the product and/or defective part(s) freight prepaid to our factory
or nearest authorized service station. Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply. 

THE SOLE AND EXCLUSIVE REMEDY FOR BREACH OF ANY AND ALL WARRANTIES WITH

RESPECT TO ANY PRODUCT SHALL BE TO REPLACE OR REPAIR AT OUR ELECTION, F.O.B. POINT OF
MANUFACTURE OR AUTHORIZED REPAIR STATION, SUCH PRODUCTS AND/OR PARTS AS PROVEN DEFECTIVE.
THERE SHALL BE NO FURTHER LIABILITY, WHETHER BASED ON WARRANTY, NEGLIGENCE OR OTHERWISE.

Unless expressly stated otherwise, guarantees in the nature of performance specifications furnished in addition to the foregoing
material and workmanship warranties on a product manufactured by us, if any, are subject to laboratory tests corrected for
field performance. Any additional guarantees, in the nature of performance specifications must be in writing and such writing
must be signed by our authorized representative. Due to inaccuracies in field testing if a conflict arises between the results of
field testing conducted by or for user, and laboratory tests corrected for field performance, the latter shall control. Components
or accessories supplied by us but manufactured by others are warranted only to the extent of and by the terms and conditions
of the original manufacturer’s warranty. 

RECOMMENDATIONS FOR SPECIAL APPLICATIONS OR THOSE RESULTING

FROM SYSTEMS ANALYSES AND EVALUATIONS WE CONDUCT WILL BE BASED ON OUR BEST AVAILABLE
EXPERIENCE AND PUBLISHED INDUSTRY INFORMATION. SUCH RECOMMENDATIONS DO NOT CONSTITUTE A
WARRANTY OF SATISFACTORY PERFORMANCE AND NO SUCH WARRANTY IS GIVEN.

This warranty shall not apply when damage is caused by (a) improper installation, (b) improper voltage (c) lightning (d) sand
or other abrasive material (e) scale or corrosion build-up due to excessive chemical content. Any modification of the original
equipment will also void the warranty. We will not be responsible for loss, damage or labor cost due to interruption of service
caused by defective parts. Neither will we accept charges incurred by others without our prior written approval.
This warranty is void if our inspection reveals the product was used in a manner inconsistent with normal industry practice
and\or our specific recommendations. The purchaser is responsible for communication of all necessary information regarding
the application and use of the product. 

UNDER NO CIRCUMSTANCES WILL WE BE RESPONSIBLE FOR ANY OTHER

DIRECT OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED

 

TO LOST PROFITS, LOST INCOME, LABOR

CHARGES, DELAYS IN PRODUCTION, IDLE PRODUCTION, WHICH DAMAGES ARE CAUSED BY ANY DEFECTS IN
MATERIAL AND\OR WORKMANSHIP AND\OR DAMAGE OR DELAYS IN SHIPMENT. THIS WARRANTY IS EXPRESSLY
IN LIEU OF ANY OTHER EXPRESS OR IMPLIED WARRANTY, INCLUDING ANY WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.

No rights extended under this warranty shall be assigned to any other person, whether by operation of law or otherwise, without
our prior written approval.

BARNES

®

420 Third Street/P.O. Box 603

83 West Drive, Brampton

Piqua, Ohio 45356-0603

Ontario, Canada L6T  2J6

Phone: (937) 778-8947

Phone: (905) 457-6223

Fax: (937) 773-7157

Fax: (905) 457-2650

www.cranepumps.com

PUMPS & SYSTEMS

A Crane Co. Company

Содержание BARNES 6SE-EHA Series

Страница 1: ...ay occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification SERIES 6SE EHA 10 30HP 1150RPM SERIES 6SE EHA 30 100HP 1750 RPM BARNES 420 Third Street P O Box 603 83 West Drive Brampton Piqua Ohio 45356 0603 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com PUMPS SYSTEMS A Crane Co Com...

Страница 2: ...W Fig 7 14 PARTS LIST 15 16 RETURNED GOODS POLICY 17 WARRANTY START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT PRESSURE GAUGE KIT Other brand and product names are trademarks or registered trademarks of their respective holders Reliance is a registered trademark of Rockwell Automation Barnes is a registered trademark of Barn...

Страница 3: ...re on any pump and on end suction and self priming pump the heat build may cause the generation of steam with resulting dangerous pressures It is recommended that a high case temperature switch or pressure relief valve be installed on the pump body ELECTRICAL 21 To reduce risk of electrical shock pump must be properly grounded in accordance with the National Electric Code NEC or Canadian Electrica...

Страница 4: ...150 or 1750 RPM Nominal UPPER BEARING Design Single Row Ball Lubrication Grease Load Radial LOWER BEARING Design Double Row Ball Lubrication Grease Load Radial Thrust MOTOR Design NEMA B Torque Curve Air Filled Squirrel Cage Induction Insulation Class F THREE PHASE Dual Votage 230 460 Requires Overload Protection to be Included in Control Panel MOISTURE SENSOR N O Requires Relay in Control Panel T...

Страница 5: ...owed provided 1 The pump is not installed under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shipping container and placed in a temperature controlled storage area B 4 Service Centers For the location of the nearest Barnes Pumps Service Center check your Barnes Engineered catalog your Barnes Pum...

Страница 6: ...pplication Any splice between the pump and the control panel must be made in accordance with the National Electric Code and all applicable state and local electric codes It is recommended that a junction box be mounted outside the sump or be of at least Nema 4 construction if located within the wet well Do not use the control cable to lift pump NOTE The white wire is NOT a neutral or ground lead b...

Страница 7: ... damage the motor and or pump To check the rotation suspend the pump freely momentarily apply power and observe the kickback Kickback should always be in a counter clockwise direction as viewed from the top of the pump motor housing D 2 1 Incorrect Rotation for Three Phase Pumps In the event that the rotation is incorrect for a three phase installation interchange any two power cable leads at the ...

Страница 8: ...rature Sensor White P2 Temperature Sensor Red W1 Moisture Sensor Orange W2 Moisture Sensor Green Ground Fig 2 G L1 L2 L3 G T1 T7 T2 T8 T3 T9 T4 T5 T6 MOTOR LEADS POWER Large Cable G R E E N B L A C K R E D W H I T E POWER Large Cable MOTOR LEADS G L1 L2 L3 G T1 T2 T3 T4 T7 T5 T8 T6 T9 G R E E N B L A C K R E D W H I T E Temperature Sensor Leads Moisture Sensor Leads CONTROL Small Cable S1 S2 W1 W2...

Страница 9: ...r damage F 1 2 Reassembly To install wear ring 7 first apply retaining compound to the bore of suction cover 6 and then press wear ring 7 into bore of suction cover 6 until seated Position gasket 10 on volute and locate suction cover 6 on volute 3 apply thread locking compound to cap screws 5 set legs 16 into place on suction plate 6 place washers 15 on cap screws 5 that are used on legs 16 and to...

Страница 10: ...20B making sure it is seated on retainer and not cocked or resting on bellows tail Slide retaining ring 20B over shaft and let rest on spring 20C Assemble impeller and volute as outlined in paragraph F 1 2 WARNING DO NOT DISASSEMBLE THE RELIANCE MOTOR IN ANY WAY EXCEPT FOR OUTER SEAL AS THIS WILL VOID WARRANTY F 3 Motor Cables Inner Shaft Seal Service The Submersible pump motor is manufactured by ...

Страница 11: ...Clean impeller cavity and inlet of any obstruction 9 Loosenunion slightly toallow trapped air to escape Verify that turn off level of switch is set so that impeller cavity is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump ...

Страница 12: ...ign configuration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and obtaining information G 4 SERIAL NUMBER The serial number block will consist of a six digit number which is specific to e...

Страница 13: ...Fig 6 320 FRAME 250 FRAME 13 ...

Страница 14: ...Fig 7 14 ...

Страница 15: ...VARIOUS CABLE LENGTHS 25FT 30FT 40FT 50FT 75FT 100FT 125FT 150FT 6SE10036EHA 250TYZ 092999 092999XC 092999XE 092999XF 092999XH 092999XL 092999XN 092999XS 6SE10046EHA 250TYZ 093000 093000XC 093000XE 093000XF 093000XH 093000XL 093000XN 093000XS 6SE15036EHA 250TYZ 069562 069562XC 069562XE 069562XF 069562XH 069562XL 069562XN 069562XS 6SE15046EHA 250TYZ 093002 093002XC 093002XE 093002XF 093002XH 093002...

Страница 16: ...50RPM 014 00117 117 12 875 014 00116 119 014 00117 119 12 750 014 00116 121 014 00117 121 12 625 014 00116 123 014 00117 123 60HP 1750RPM 12 500 014 00116 125 014 00117 125 12 375 014 00116 127 014 00117 127 12 250 014 00116 129 014 00117 129 12 125 014 00116 131 014 00117 131 12 000 014 00116 133 15HP 1150RPM 014 00117 133 11 875 014 00116 135 014 00117 135 11 750 014 00116 137 014 00117 137 50HP...

Страница 17: ...of the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable ...

Страница 18: ...ield performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control Components or accessories suppl...

Страница 19: ...bottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Motor measured at pump control Red Black Ohms Red White Ohms White Black Ohms Resistance Of Ground Circuit Between Control Panel and Outside of Pump Ohms MEG Ohms Check of Insulation Red to Ground White...

Страница 20: ...n Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks Does check valves operate properly Flow Does station appear to operate at proper rate Pump down time Noise Level High Medium Low Comments Equipment Difficulties during start up MANUALS Has operator ...

Страница 21: ...ERIAL NO PART NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warranty Service Group IMPORTANT If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Страница 22: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE ...

Отзывы: