13
MODEL
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
T
OR
AMPS
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
MAIN - ST
AR
T
XSHVV Pump
8XSHVV25098*
25.0
208
3
60
870
H
82.3
1.2
98.8
400.0
138319
2/4 - 18/4
1.47 ± .03
.121
230
84.0
94.5
8XSHVV25048*
25.0
460
3
60
870
H
42.0
1.2
47.2
200.0
138317
8/4 - 18/4
1.12 ± .02
.483
8XSHVV25058*
25.0
575
3
60
870
H
33.6
1.2
37.8
160.0
138317
8/4 - 18/4
1.12 ± .02
.77
8XSHVV30098*
30.0
208
3
60
870
F
98.8
1.2
124.1
400.0
138319
2/4 - 18/4
1.47 ± .03
.121
230
94.5
108.6
8XSHVV30048*
30.0
460
3
60
870
F
47.2
1.2
54.3
200.0
138317
8/4 - 18/4
1.12 ± .02
.483
8XSHVV30058*
30.0
575
3
60
870
F
37.8
1.2
43.5
160.0
138317
8/4 - 18/4
1.12 ± .02
.77
XSHDU Pump
8XSHDU25094
25.0
208
3
60
1750
G
77.8
1.2
93.4
359.0
138319
2/4 - 18/4
1.47 ± .03
.098
230
71.4
82.3
8XSHDU30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319
2/4 - 18/4
1.47 ± .03
.098
230
82.3
98.7
8XSHDU40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319
2/4 - 18/4
1.47 ± .03
.063
8XSHDU40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
138318
6/4 - 18/4
1.14 ± .03
.248
8XSHDU40054
40.0
575
3
60
1750
E
42.4
1.2
50.6
194.4
138317
8/4 - 18/4
1.12 ± .02
.382
8XSHDU50044
50.0
460
3
60
1750
F
67.1
1.2
79.0
339.0
138318
6/4 - 18/4
1.14 ± .03
.15
8XSHDU50054
50.0
575
3
60
1750
F
53.7
1.2
63.2
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
8XSHDU60044
60.0
460
3
60
1750
E
79.0
1.2
95.5
339.0
138319
2/4 - 18/4
1.47 ± .03
.15
8XSHDU60054
60.0
575
3
60
1750
E
63.2
1.2
76.4
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
8XSHDU20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.14 ± .03
.111
7
230
57.2
69.8
8XSHDU25096
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
70.8
82.6
8XSHDU25046
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
8XSHDU25056
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
8XSHDU10098
10.0
208
3
60
870
L
37.2
1.2
42.0
230.0
138317
8/4 - 18/4
1.12 ± .02
.199
230
38.6
42.2
8XSHDU10048
10.0
460
3
60
870
L
19.3
1.2
21.1
115.0
138317
8/4 - 18/4
1.12 ± .02
.795
8XSHDU10058
10.0
575
3
60
870
L
15.4
1.2
16.9
92.0
138317
8/4 - 18/4
1.12 ± .02
1.27
Moisture and
Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.
▲ Cord Suffix: XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
▲ Cord sold separately (After March-2016 ONL
Y). Pumps built Before March-2016 refer to Cord
Assembly Kit, see page 28.
* Select impeller diameter when ordering.
CHART ‘G’