XSHDI Pump
4XSHDI20064
20.0
208
3
60
1750
G
63.0
1.2
74.6
323.0
138318
6/4 - 18/4
1.14 ± .03
0.098
4XSHDI25094
25.0
208
3
60
1750
G
77.8
1.2
93.4
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
71.4
82.3
4XSHDI30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319
2/4 - 18/4
1.47 ± .03
0.098
230
82.3
98.7
4XSHDI40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319
2/4 - 18/4
1.47 ± .03
.063
4XSHDI40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
6/4 - 18/4
1.14 ± .03
.248
4XSHDI40054
40.0
575
3
60
1750
E
42.4
1.2
50.6
194.4
138317
8/4 - 18/4
1.12 ± .02
.382
4XSHDI50044
50.0
460
3
60
1750
F
67.1
1.2
79.0
339.0
138318
6/4 - 18/4
1.14 ± .03
.15
4XSHDI50054
50.0
575
3
60
1750
F
53.7
1.2
63.2
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
4XSHDI60044
60.0
460
3
60
1750
E
79.0
1.2
95.5
339.0
138319
2/4 - 18/4
1.47 ± .03
.15
4XSHDI60054
60.0
575
3
60
1750
E
63.2
1.2
76.4
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
4XSHDI20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.14 ± .03
.111
7
230
57.2
69.8
4XSHDI25096
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
70.8
82.6
4XSHDI25046
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
4XSHDI25056
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
4XSHDI30096
30.0
208
3
60
1150
E
90.8
1.2
114.9
354.0
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
82.6
99.7
4XSHDI30046
30.0
460
3
60
1150
E
41.3
1.2
49.9
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
4XSHDI30056
30.0
575
3
60
1150
E
33.0
1.2
39.9
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
4XSHDI40036
40.0
230
3
60
1150
E
110.4
1.2
131.8
476.0
138319
2/4 - 18/4
1.47 ± .03
.0819
4XSHDI40046
40.0
460
3
60
1150
E
55.2
1.2
65.9
238.0
138318
6/4 - 18/4
1.14 ± .03
.3277
4XSHDI40056
40.0
575
3
60
1150
E
44.2
1.2
52.7
190.4
138317
8/4 - 18/4
1.12 ± .02
.5443
Moisture and
Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.