32
•
This procedure is the same for the Advanced Level.
2.2.3 View a Specific Function Using Jump Code Location
Fig. 2.2.2: Programming flow chart showing how to view a specific function [Code No.]
of a group level.
PROG
SER
Jump
00
04
SER
Jump
00
05
SER
Jump
00
05
ENTER
SER
Jump
00
15
SER
Jump
00
04
SER
Freq.
15
60.00 Hz
In this example, the user will use the jump code location in the Service Level to
quickly get to Freq. Max. [SER: Code No. 15]
•
Press the PROG key. This places you in
programming mode. The cursor will
appear on the least significant digit.
•
Press the UP arrow key until you get the
number 5.
•
Press the SHIFT arrow key once to move
to the next significant digit.
•
Press the UP arrow key once.
•
Press the ENTER key. This will take you
to Freq. Max. [SER: Code No. 15]
For more information contact: Sievert Crane and Hoist, (708) 771-1600, [email protected], www.sievertcrane.com