background image

 

                               6 

 

Crane

 

Electronics Ltd

 

The force in torque management 

 

Crane Electronics Ltd 

Watling Drive 

Sketchley Meadows 

Hinckley LE10 3EY 

Tel: +44(0) 1455 25 14 88 

www.crane-electronics.com 

 

 
 

Weight:

 50 Lbs [23 kg].  

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

FEATURES AND DIMENSIONS – WM10K 

Содержание WM10K

Страница 1: ...0 1455 25 14 88 www crane electronics com Operators Manual WM10K Torque Tester Manual Issue 1 Crane Electronics Ltd Notice ALL RIGHTS RESERVED Reproduction of any part of this manual in any form whatsoever without the prior permission in writing from Crane Electronics Ltd is forbidden Copyright September 2021 by Crane Electronics Ltd ...

Страница 2: ...el 44 0 1455 25 14 88 www crane electronics com Contents 2 UKCA Marking CE Marking Compliance 3 Product Disposal About this Manual 4 Packing list 5 Features Dimensions 6 Specifications 7 Technical Features 9 Icons 9 Start Up 10 Operation 12 Fixed Icons 12 Measurement Units 13 Filters 13 Maintenance 14 Troubleshooting 15 CONTENTS ...

Страница 3: ...ed and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com...

Страница 4: ...to accept the return of your product at your cost for recycling or alternatively for more detailed information about recycling of this product please contact your local authority or the Distributor Company where you have purchased the product Battery disposal to take place in line with the AMENDED BATTERIES DIRECTIVE 2013 56 EU Batteries must not go to landfill Check with local legislation Crane E...

Страница 5: ... Items are supplied with the WM10K dependent on model specification purchased 1 x WM10K torque tester includes 1 x dynamic run down fixture with 1 5 female square drive 1 x standard reaction stop 1 x secondary reaction post Can be supplied with or without a protective carry case Please ensure all items are present and notify Crane Electronics Ltd immediately of any shortages PACKING LIST ...

Страница 6: ...tronics Ltd The force in torque management Crane Electronics Ltd Watling Drive Sketchley Meadows Hinckley LE10 3EY Tel 44 0 1455 25 14 88 www crane electronics com Weight 50 Lbs 23 kg FEATURES AND DIMENSIONS WM10K ...

Страница 7: ...ns An integrated transducer measures the torque and communicates the results to the digital display module The run down fixture can be adjusted vertically to accommodate various tool designs Base plate The base plate houses the run down fixture reaction stop and digital display module It features three sturdy legs end slot to transport the unit and can be fastened down to a flat surface Reaction s...

Страница 8: ...module USB Connections The USB interface cable shown below is used when downloading to a computer or other device The values are sent every time a reading in Peak mode is taken on the WM10K Charging the Battery Follow the standard operating procedures in your workplace and be sure to observe all communicated safety precautions The battery for the WM10K should last approximately 12 hours when fully...

Страница 9: ...ata output is a requirement via USB type B connector Operating Temperature 32 F 0 C to 122 F 50 C Accuracy The accuracy of the WM10K is calibrated to meet or exceed 1 of FSD from 2 to 8 of torque range and 1 of reading from 8 to 100 of torque range Range 2 to 100 148 Ft lbs to 7375 Ft lbs 200Nm to 10 000NM Filter Selectable Hz filter 125 250 500 1000 1500 and 2000 Torque Measurement Display up to ...

Страница 10: ... module is plugged in or sufficiently charged to operate Select and position an appropriate adaptor onto the run down fixture to allow the proper mounting of the tool Mount the tool vertically onto the run down fixture positioning the reaction arm between the reaction stop wings and lower the tool into position For safe operation the square drive of the tool must fit into the run down fixture with...

Страница 11: ...ly adjust the run down fixture use the appropriate adapter that provides the required positioning to achieve full reaction arm engagement It is important to reverse loosen the run down fixture for testing Reaction Stop To adjust the reaction stop loosen the handle as shown in the image below Slide the reaction stop to properly position the reaction arm and fully engage the reaction stop per manufa...

Страница 12: ...the tool stalls the peak reading will momentarily appear on the display module and then is saved For the next cycle it is important to reverse the tool and loosen the run down fixture NOTE The default setting for the torque reading is peak To take a peak reading ensure that the Peak icon appears under the torque reading on the display module see image below Power Turns the display unit Off and On ...

Страница 13: ...wrenches Track Mode The track mode displays the torque as it is being applied to the transducer This mode is used primarily for verifying the calibration of the WM10K unit Press the Menu button and then press the left and right arrow keys to scroll through the measurement units selecting either Nm or Ft lbs Use this option to select the filter value Press the Menu button twice and using the arrow ...

Страница 14: ...iodic lubrication of the run down fixture is critical to the longevity of the tool The run down bolt and disc spring should be periodically removed and inspected and if necessary coated with a high pressure anti seize lubricant Crane recommends Molybdenum Disulfide or a lubricant with similar properties After proper lubrication replace the run down disc spring Some units have additional disc sprin...

Страница 15: ...ected Verify that the display is operating in the desired engineering units Check that the filter setting is suitable for the application and the tool Inspect transducer for overload yield by selecting track mode on the display If there is a large value displayed with no strain on the transducerthetransducerhasbeenover loadedandrequiresservice Joint Run Down Symptom Remedy Threaded components do n...