20
Troubleshooting cont.
POSSIBLE PROBLEM
ERROR DISPLAYED
CODE
RECOMMENDATION
The Baler will not start.
STOP BUTTON
IS IN THE “STOP”
POSITION
1
Pull the STOP button out to the “RUN”
position.
ELECTROMAGNETIC
LOCK FAILED
“OPEN”
2
Close and latch the Loading Door.
Check the Door Position Sensor for proper
alignment to the magnet on the Door Strike
Plate.
Check the Electromagnetic Lock.
Replace the Electromagnetic Lock.
ELECTROMAGNETIC
LOCK FAILED
“CLOSED”
3
Cycle power to unlock the Loading Door.
Close and latch the Loading Door.
Check the Door Position Sensor for proper
alignment to the magnet on the Door Strike
Plate.
Check the Electromagnetic Lock.
Replace the Electromagnetic Lock.
When you release the key the
Baler stops.
UPPER MAGNETIC
INTERLOCK SWITCH
FAILED “OPEN”
4
Close and latch the Loading Door.
Check the Upper Magnetic Interlock Switch
for proper alignment to the magnet on the Load-
ing Door.
Check the Upper Magnetic Interlock
Switch.
Replace the Upper Magnetic Interlock
Switch.
When the ram retracts to the
top, the Baler continues to
run.
UPPER MAGNETIC
INTERLOCK SWITCH
FAILED “CLOSED”
5
Check the Upper Magnetic Interlock Switch
mounting bracket for proper operation.
Check the Upper Magnetic Interlock
Switch.
Replace the Upper Magnetic Interlock
Switch.
The Baler will not start.
MOTOR STARTER
FAILED
6
Check the Motor Starter Overload and press
“RESET” if necessary.
Check power to the Motor Starter coil.
Replace Motor Starter.
PICOVB07 TROUBLESHOOTING GUIDE
Содержание VB-42-B
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 23: ...23 Parts Diagrams 4 9 8 7 6 12 14 16 1 2 3 10 11 13 15 5 Chassis Loading Door Fig 9 ...
Страница 28: ...28 Electrical Schematic Fig 13 ...
Страница 29: ...29 Hydraulic Schematics ...