14
CraftBot 3
4. Repeat the process with the two back knobs. First the right back, then the left back knob will be
adjusted.
5. Before switching from knob to knob, please remove the leveling card. When the nozzle is in the
correct location replace the card as necessary for further testing at that location point.
6. Process is to be repeated twice to make sure that all 3 knobs are in the correct position.
7. As a result, the building plate should be evenly calibrated.
8. You can return to the main menu by pressing the right arrow.
5.4.2. DUAL HEAD CALIBRATION (Z)
The Z axis must be calibrated so that the two heads are at the same height and are at the same distance
from the build platform. If there is a height variation between the two heads, it will be visible on the
printed object.
Calibration process:
1. Heat up the heads and remove the filaments!
2. Select the Settings menu
on the LCD screen and go to the 5th. page using the right arrow. Select
the Z calibration icon
. 2 printheads icon.)
3. The calibration must be initiated
4. select the 2 arrow icon