Craftsman 83.2655 Скачать руководство пользователя страница 5

5

 

Risk of electric shock. Can shock, burn or kill. 

Make certain that the pump is unplugged before attempting 
to service or remove any component.
1. 

The motor in the unit is sealed in oil. No additional 
lubrication is necessary.

2. 

NOTICE Disassembly of the motor assembly will void 
the warranty. It might also cause internal leakage and 
damage to the unit. If repairs are required, return the 
pump to the dealer from whom it was purchased.

3. 

Inlet screen should be kept clean and free of all 
foreign objects.

PUMP CLEANING

NOTICE Attempting to disassemble motor will void 
the warranty.
1. 

Disconnect power cord from electrical outlet before 
working on pump. The volute screen and shield may 
be removed to replace impeller or clean pump of mud 
or debris.

 

Risk of electric shock. Can shock, burn or 

kill. Do not handle pump or pump motor with wet hands or 
when standing on wet or damp surface, or in water.
NOTICE Do not use this pump in water with fish present. If 
any oil leaks out of the motor it can kill fish.
1. 

Shaft seal depends on water for lubrication. Do not 
operate pump unless it is in at least 3/16” (4.75mm) 
of water as seal may be damaged if allowed to 
run dry.

2. 

Motor is equipped with automatic reset thermal 
protector. If temperature in motor should rise unduly, 
switch will cut off all power before damage can be 
done to motor. When motor has cooled sufficiently, 
switch will reset automatically and restart motor. If 
protector trips repeatedly, pump should be checked 
as to cause of difficulty. Low voltage, long extension 
cords, clogged impeller, very low head or lift, etc., 
could cause cycling.

3. 

Pump will pump water down to 3/16” (4.75mm); this 
means that it will not remove all water. If unit has 
been operating and suddenly no water comes out of 
discharge hose, shut off unit immediately. Water level 

is probably very low and unit has broken prime. Use 
mop or squeegee to remove remaining water.

 

 

 

Risk of electric shock. Can shock, 

burn or kill. Before attempting to check why unit has 
stopped operating, disconnect power from unit. Do 
not handle pump with wet hands or when standing 
on wet or damp surfaces, or in water. Failure to 
follow precaution can result in personal injury and/or 
property damage.

AIRLOCKS

When a pump airlocks, it runs but does not move any 
water. An airlock will cause the pump to overheat and 
fail. This pump has an anti-airlock hole in the bottom of 
the pump body (see REPAIR PARTS). If you suspect an 
airlock, unplug the pump, clean out the anti-airlock hole 
with a paper clip or piece of wire, and restart pump.
NOTICE This hole allows the pump to start priming within 
15 seconds in as little as 1/2” of water. NEVER restart 
pump in less than 1/2” of water. Leakage from the anti-
airlock hole is normal.

OPERATION

MAINTENANCE

Содержание 83.2655

Страница 1: ...this product read this manual and follow all its Safety Rules and Operating Instructions Safety Assembly Operation Maintenance Parts Español p 8 Sears Brands Management Corporation Hoffman Estates IL 60179 U S A www craftsman com SUBMERSIBLE UTILITY PUMP Model 83 2655 ...

Страница 2: ...before servicing any component 4 Drain water from the system before servicing 5 Secure the discharge line before starting the pump An unsecured discharge line will whip possibly causing personal injury and or property damage 6 Check hoses for weak or worn condition before each use making certain that all connections are secure 7 Periodically inspect pump and system components Perform routine maint...

Страница 3: ...ur electrical outlet should be the 3 prong polarized type with an internal ground A separate 15 amp GFCI branch electrical circuit is recommended DO NOT USE AN EXTENSION CORD TESTING FOR GROUND For your safety check your outlet for ground using a Circuit Analyzer Figure A A Circuit Analyzer will tell you by a pattern of lights if the power neutral and ground wires are correctly connected to your o...

Страница 4: ... power to the motor before the heat damages it internally The overload will reset automatically and the pump will restart after the pump cools down below the danger point Risk of electric shock Can shock burn or kill DO NOT attempt to work on the pump or motor if the overload seems to have tripped The motor may restart without warning at any time You could be injured and the pump damaged if it sta...

Страница 5: ...tch will cut off all power before damage can be done to motor When motor has cooled sufficiently switch will reset automatically and restart motor If protector trips repeatedly pump should be checked as to cause of difficulty Low voltage long extension cords clogged impeller very low head or lift etc could cause cycling 3 Pump will pump water down to 3 16 4 75mm this means that it will not remove ...

Страница 6: ...t b Check for blown fuses or tripped circuit breakers at fuse box circuit breaker box c If a and b above check OK plug in a light that you know works If it lights take your pump to Sears for service If it doesn t light the electrical circuit is faulty consult a licensed electrician 2 Pump starts but blows fuses trips circuit breakers After disconnecting power to pump remove the screen and shield f...

Страница 7: ...ription Qty Part Number 1 Power Cord 1 PS117 51 TSU 2 Motor 1 3 Impeller 1 PS5 25P 4 Shield 1 PS70 3P 5 Screen 1 PS8 5P 6 8 x 5 8 Pan Head Screw 3 Garden Hose Adapter 1 FT0013 43 Not illustrated If motor fails replace entire pump Standard hardware item purchase locally ...

Страница 8: ...es de realizar trabajos de reparación 5 Sujetar la línea de descarga antes de encender la bomba Una línea de descarga que no esté debidamente sujeta puede saltar con la posibilidad de que provoque lesiones personales y o daños materiales 6 Verificar que las mangueras no estén débiles o desgastadas antes de cada uso asegurándose de que todas las conexiones estén seguras 7 Inspeccionar la bomba y lo...

Страница 9: ...una manguera de jardín de 3 4 instalar el adaptador provisto con la bomba b Para instalarla con una tubería rígida utilizar una tubería de plástico Envolver la rosca con cinta selladora de roscas de tubos de teflón PTFE Atornillar la tubería en la bomba apretando a mano de 1 a 1 vuelta AVISO No se debe tratar de desarmar la bomba más allá de la remoción de la malla de admisión Toda evidencia de ma...

Страница 10: ...encender después de que se haya enfriado a un nivel inferior al punto de peligro Riesgo de choque eléctrico Puede provocar choque quemadura o muerte NO se debe intentar de trabajar en la bomba o en el motor si parece que el protector de sobrecarga se ha disparado El motor puede volver a encenderse en cualquier momento sin ninguna advertencia Si el motor se enciende mientras se está trabajando en e...

Страница 11: ... reposicionará automáticamente y volverá a encender el motor Si el protector se dispara repetidamente será necesario inspeccionar la bomba para verificar cuál es la causa de este problema Una baja tensión cordones de extensión largos un impulsor obstruido muy poca altura o aspiración etc pueden provocar la sucesión de los ciclos 3 La bomba aspirará agua hasta dejar una profundidad de 3 16 4 75 mm ...

Страница 12: ...usibles disyuntores c Si los puntos a y b que preceden están OK se recomienda enchufar una lámpara que funciona correctamente Si la lámpara se enciende se deberá llevar la bomba a Sears para obtener servicio Si no se enciende el circuito eléctrico ha fallado y se deberá consultar a un electricista certificado 2 La bomba se enciende pero funde los fusibles dispara los disyuntores Después de descone...

Страница 13: ...aire 1 PS117 51 TSU 2 Cordón eléctrico 1 3 Motor 1 PS5 25P 4 Impulsor 1 PS70 3P 5 Protector 1 PS8 5P 6 Malla 3 Tornillo de cabeza de cono achatado 8 de 5 8 1 FT0013 43 Adaptador de manguera de jardín No se ilustra Si el motor falla se debe reemplazar toda la bomba Artículo de ferretería estándar se debe adquirir a nivel local ...

Страница 14: ...14 NOTAS ...

Страница 15: ...15 NOTAS ...

Страница 16: ...d owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call anytime for the location of your nearest Sears Parts R...

Отзывы: