Craftsman 83.2655 Скачать руководство пользователя страница 2

2

CONTENTS

INTRODUCTION/WARRANTY .....................................2
SAFETY ........................................................................2
INSTALLATION .............................................................3
SERVICE .......................................................................4
PERFORMANCE ..........................................................5
PARTS ..........................................................................6

INTRODUCTION

Please read our instructions before you install and use your 
new pump; this will help you obtain full value and good 
service from it. It will also help you avoid needless service 
costs that result from causes we cannot control and cannot 
cover in our warranty.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS - This manual contains 
important instructions that should be followed during 
installation, operation, and maintenance of the product. 

 This is the safety alert symbol. When you see this 

symbol on your pump or in this manual, look for one of 
the following signal words and be alert to the potential for 
personal injury!

 indicates a hazard which, if not avoided, will 

result in death or serious injury.

 indicates a hazard which, if not avoided, could 

result in death or serious injury.

 indicates a hazard which, if not avoided, could 

result in minor or moderate injury.
NOTICE addresses practices not related to personal injury.
Carefully read and follow all safety instructions in this 
manual and on pump.
Keep safety labels in good condition. Replace missing or 
damaged safety labels.
1. 

Know the pump application, limitations, and 
potential hazards.

 

NOTICE This unit is not designed as a waterfall or 
fountain pump, or for applications involving salt water 
or brine! Use with waterfalls, fountains, salt water or 
brine will void warranty.

 

Do not use where water recirculates.

  

 

Risk of explosion. Do not use in 

explosive atmospheres. Pump water only with this 
pump. Failure to follow this warning can result in 
personal injury and/or property damage.

2. 

Disconnect power before servicing.

3. 

Release all pressure within the system before 
servicing any component.

4. 

Drain water from the system before servicing.

5. 

Secure the discharge line before starting the pump. 
An unsecured discharge line will whip, possibly 
causing personal injury and/or property damage.

6. 

Check hoses for weak or worn condition before each 
use, making certain that all connections are secure.

7. 

Periodically inspect pump and system components. 
Perform routine maintenance as required 
(See MAINTENANCE).

8. 

Provide a means of pressure relief for pumps whose 
discharge line can be shut-off or obstructed.

9. 

Personal Safety:

a. 

Wear safety glasses at all times when working 
with pumps.

b. 

Keep work area clean, uncluttered and properly 
lighted – replace all unused tools and equipment.

c. 

Keep visitors at a safe distance from the 
work area.

d. 

Make workshop child-proof – with padlocks, 
master switches, and by removing starter keys.

10.  When wiring an electrically driven pump, follow 

electrical and safety codes, as well as the most 
recent National Electrical Code.

11.  This equipment is only for use on 115 volt (single 

phase) and is equipped with an approved 3-conductor 
cord and 3-prong, grounding-type plug.

CRAFTSMAN® THREE-YEAR FULL WARRANTY

FOR THREE YEARS from the date of purchase, this product is warranted against any defects in material or 
workmanship. A defective product will be replaced free of charge. For warranty coverage details to obtain free 
replacement, visit the website: www.craftsman.com
This warranty is void if this product is ever used while providing commercial services or if rented to another person.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears Brands Management Corporation Hoffman Estates, IL 60179

GENERAL SAFETY INFORMATION

California Proposition 65 Warning

 This product and related accessories contain chemicals known to the State of California to cause cancer, birth 

defects or other reproductive harm.

Содержание 83.2655

Страница 1: ...this product read this manual and follow all its Safety Rules and Operating Instructions Safety Assembly Operation Maintenance Parts Español p 8 Sears Brands Management Corporation Hoffman Estates IL 60179 U S A www craftsman com SUBMERSIBLE UTILITY PUMP Model 83 2655 ...

Страница 2: ...before servicing any component 4 Drain water from the system before servicing 5 Secure the discharge line before starting the pump An unsecured discharge line will whip possibly causing personal injury and or property damage 6 Check hoses for weak or worn condition before each use making certain that all connections are secure 7 Periodically inspect pump and system components Perform routine maint...

Страница 3: ...ur electrical outlet should be the 3 prong polarized type with an internal ground A separate 15 amp GFCI branch electrical circuit is recommended DO NOT USE AN EXTENSION CORD TESTING FOR GROUND For your safety check your outlet for ground using a Circuit Analyzer Figure A A Circuit Analyzer will tell you by a pattern of lights if the power neutral and ground wires are correctly connected to your o...

Страница 4: ... power to the motor before the heat damages it internally The overload will reset automatically and the pump will restart after the pump cools down below the danger point Risk of electric shock Can shock burn or kill DO NOT attempt to work on the pump or motor if the overload seems to have tripped The motor may restart without warning at any time You could be injured and the pump damaged if it sta...

Страница 5: ...tch will cut off all power before damage can be done to motor When motor has cooled sufficiently switch will reset automatically and restart motor If protector trips repeatedly pump should be checked as to cause of difficulty Low voltage long extension cords clogged impeller very low head or lift etc could cause cycling 3 Pump will pump water down to 3 16 4 75mm this means that it will not remove ...

Страница 6: ...t b Check for blown fuses or tripped circuit breakers at fuse box circuit breaker box c If a and b above check OK plug in a light that you know works If it lights take your pump to Sears for service If it doesn t light the electrical circuit is faulty consult a licensed electrician 2 Pump starts but blows fuses trips circuit breakers After disconnecting power to pump remove the screen and shield f...

Страница 7: ...ription Qty Part Number 1 Power Cord 1 PS117 51 TSU 2 Motor 1 3 Impeller 1 PS5 25P 4 Shield 1 PS70 3P 5 Screen 1 PS8 5P 6 8 x 5 8 Pan Head Screw 3 Garden Hose Adapter 1 FT0013 43 Not illustrated If motor fails replace entire pump Standard hardware item purchase locally ...

Страница 8: ...es de realizar trabajos de reparación 5 Sujetar la línea de descarga antes de encender la bomba Una línea de descarga que no esté debidamente sujeta puede saltar con la posibilidad de que provoque lesiones personales y o daños materiales 6 Verificar que las mangueras no estén débiles o desgastadas antes de cada uso asegurándose de que todas las conexiones estén seguras 7 Inspeccionar la bomba y lo...

Страница 9: ...una manguera de jardín de 3 4 instalar el adaptador provisto con la bomba b Para instalarla con una tubería rígida utilizar una tubería de plástico Envolver la rosca con cinta selladora de roscas de tubos de teflón PTFE Atornillar la tubería en la bomba apretando a mano de 1 a 1 vuelta AVISO No se debe tratar de desarmar la bomba más allá de la remoción de la malla de admisión Toda evidencia de ma...

Страница 10: ...encender después de que se haya enfriado a un nivel inferior al punto de peligro Riesgo de choque eléctrico Puede provocar choque quemadura o muerte NO se debe intentar de trabajar en la bomba o en el motor si parece que el protector de sobrecarga se ha disparado El motor puede volver a encenderse en cualquier momento sin ninguna advertencia Si el motor se enciende mientras se está trabajando en e...

Страница 11: ... reposicionará automáticamente y volverá a encender el motor Si el protector se dispara repetidamente será necesario inspeccionar la bomba para verificar cuál es la causa de este problema Una baja tensión cordones de extensión largos un impulsor obstruido muy poca altura o aspiración etc pueden provocar la sucesión de los ciclos 3 La bomba aspirará agua hasta dejar una profundidad de 3 16 4 75 mm ...

Страница 12: ...usibles disyuntores c Si los puntos a y b que preceden están OK se recomienda enchufar una lámpara que funciona correctamente Si la lámpara se enciende se deberá llevar la bomba a Sears para obtener servicio Si no se enciende el circuito eléctrico ha fallado y se deberá consultar a un electricista certificado 2 La bomba se enciende pero funde los fusibles dispara los disyuntores Después de descone...

Страница 13: ...aire 1 PS117 51 TSU 2 Cordón eléctrico 1 3 Motor 1 PS5 25P 4 Impulsor 1 PS70 3P 5 Protector 1 PS8 5P 6 Malla 3 Tornillo de cabeza de cono achatado 8 de 5 8 1 FT0013 43 Adaptador de manguera de jardín No se ilustra Si el motor falla se debe reemplazar toda la bomba Artículo de ferretería estándar se debe adquirir a nivel local ...

Страница 14: ...14 NOTAS ...

Страница 15: ...15 NOTAS ...

Страница 16: ...d owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call anytime for the location of your nearest Sears Parts R...

Отзывы: