background image

12

GENERAL MAINTENANCE

When servicing, use only identical 

replacement parts. Use of any other parts may create a 

hazard or cause product damage.

Always wear safety goggles or safety 

glasses with side shields during power tool operation or when 

blowing dust. If operation is dusty, also wear a dust mask.

Always release all pressure, disconnect 

from power supply, and allow unit to cool to the touch before 

cleaning or making repairs on the air compressor.

Humidity in the air causes condensation to form in the air tank. 

This condensation should be drained daily and/or every hour, 

using the instructions found in 

Draining the Tank

.

The safety valve automatically releases air if the air receiver 

pressure exceeds the preset maximum. Check the safety valve 

before each use following the instructions found in 

Checking the 

Safety Valve

.

Inspect the tank yearly for rust, pin holes, or other imperfections 

that could cause it to become unsafe.
Avoid using solvents when cleaning plastic parts. Most plastics 

are susceptible to damage from various types of commercial 

solvents and may be damaged by their use. Use clean cloths to 

remove dirt, dust, oil, grease, etc.

WARNING

WARNING

WARNING

Do not at any time let brake fluids, gasoline, 

petroleum-based products, penetrating oils, etc., come in 

contact with plastic parts. Chemical can damage, weaken 

or destroy plastic which may result in serious personal 

injury. Electric tools used on fiberglass material, wall-board, 

spackling compounds, or plaster are subject to accelerated 

wear and possible premature failure because the fiberglass 

chips and grindings are highly abrasive to bearings, brushes, 

commutators, etc. Consequently, we do not recommend 

using this tool for extended work on these type of materials. 

However, if you do work with any of these materials, it is 

extremely important to clean the tool using compressed air.

LUBRICATION

All the bearings in this tool are lubricated with a sufficient amount 

of high grade lubricant for the life of the unit under normal 

operating conditions. Therefore, no further lubrication of the 

bearings is required.

WARNING

MAINTENANCE

Maintenance schedule

Items to check/change

Before 

use

Daily

Every 

hour

Checking the safety valve

Overall unit visual check

Draining the tank

Check power cord for damage

STORAGE

END OF OPERATION/STORAGE

  Turn the ON/OFF switch to the 

OFF (O)

 position.

  Unplug power cord from wall outlet and wrap it to prevent 

damage when not in use.

  Wearing safety glasses drain tank of air by pulling the ring 

on the safety valve. Use other hand to deflect fast moving air 

from being directed toward your face.

  Drain tank of condensation by opening drain valve on bottom 

of tank. Tank pressure should be below 10 psi when draining 

tank.

  Air hose should be disconnected from compressor and hung 

open ends down to allow any moisture to drain.

  Compressor and hose should be stored in a cool, dry place.

Содержание 107.10265

Страница 1: ... and follow all its Safety Rules and Operating Instructions AIR COMPRESSOR Safety Instructions Assembly Operation Maintenance Troubleshooting Guide Storage Parts List Español p 15 Model No 107 10265 2 Gallon Oil Free Portable Air Compressor 12 15 2014 Part No 9041424 ...

Страница 2: ...uct will be repaired or replaced at option of seller For warranty coverage details to obtain free replacement visit the web page www craftsman com warranty This warranty does not cover inflation nozzles or needles sealing tape or the hose which are expendable parts that can wear out from normal use within the warranty period This ONE YEAR warranty is void if this product is ever used while providi...

Страница 3: ...orms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when loading operating or servicing this tool Eye protection is required to guard against flying fasteners and debris which could cause severe eye injury The employer and or user must ensure that proper eye protection is worn We...

Страница 4: ...ill not be used for a while it is best to leave the drain valve open until such time as it is to be used This will allow moisture to com pletely drain out and help prevent corrosion on the inside of tank WARNING Check hoses for weak or worn condition before each use making certain all connections are secure Do not use if a defect is found Purchase a new hose or take to a qualified service center f...

Страница 5: ... mask if the operation is dusty Following this rule will reduce the risk of serious personal injury Do not use this air compressor to spray chemicals Your lungs can be damaged by inhaling toxic fumes A respirator may be necessary in dusty environments or when spraying paint Do not carry while painting Inspect tool cords and hoses periodically and if damaged have repaired at a qualified service cen...

Страница 6: ...e a loss of power and the motor will overheat If the air compressor does not operate when plugged into an outlet double check the power supply SPEED AND WIRING 1 The no load speed of the electric motor varies by model and specification The motor speed is not constant and decreases under a load or with lower voltage For voltage the wiring in a shop is as important as the motor s horsepower rating 2...

Страница 7: ...Pump Produces the compressed air with a reciprocating piston contained within the cylinder Regulator Pressure Gauge Outlet pressure Displays the current line pressure Line pressure is adjusted by rotating the pressure regulator knob Safety Valve Prevents air pressure in the air tank from rising over a predetermined limit SCFM Standard Cubic Feet Per Minute A unit of measure of air delivery L min L...

Страница 8: ...oses and compressed air is forced out through the exhaust valve into the discharge line through the check valve and into the air tank On Off power switch This switch is used to start or stop the air compressor Moving the switch to the ON position will provide automatic power to the pressure switch which will allow the motor to start when the air tank pressure is below the factory set cut in pressu...

Страница 9: ...wrong gauge wire used To reset the air compressor Turn the air compressor off Unplug the air compressor and allow it to cool for 30 minutes Plug the air compressor into an approved outlet Turn the air compressor on Air filter intake This filter is designed to clean air coming into the pump and requires no maintenance when operated in accordance with the warnings and operating instruction outlined ...

Страница 10: ...g the knob fully counterclockwise will completely stop the flow of air NOTE Always use the minimum amount of pressure necessary for your application Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently When finished always drain the tank and unplug the unit Never leave the unit plugged in and or running unattended Check the ai...

Страница 11: ... loosened from this device could fly up and hit you Failure to heed this warning could result in death or serious personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand Turn the air compressor on and allow the tank to fill The compressor will shut off when...

Страница 12: ...y plastic which may result in serious personal injury Electric tools used on fiberglass material wall board spackling compounds or plaster are subject to accelerated wear and possible premature failure because the fiberglass chips and grindings are highly abrasive to bearings brushes commutators etc Consequently we do not recommend using this tool for extended work on these type of materials Howev...

Страница 13: ...or to a service center The thermal overload protector cuts out repeatedly 1 The voltage from the power supply is low 2 A poorly ventilated room is causing the motor to overheat 3 The gauge wire or the length of extension cord is wrong 1 Check the voltage with a voltmeter 2 Move the compressor to well ventilated area 3 Check for proper gauge wire and cord length The air receiver pressure drops when...

Страница 14: ...5 SWITCH SUPPORT 1 502 9052125 GAUGE 1 503 9053408 T CONNECTOR 1 505 9064821 LOCK CABLE 1 506 9101978 SCREW TCEI M6x14 4 507 9142591 SCREW PARKER 3 9x16 2 508 9101305 SCREW TCEI M6x25 2 509 9103525 SCREW TSEI 4x12 2 510 9104153 SCREW M3x6 2 PUMP 9417263 PUMP 1 601 9045721 25 COIL HOSE 1 602 9045805 BLOW GUN 1 603 9045806 KIT QUICK CONN PTFE THREAD SEALING TAPE LONG INFLATION CHUCK 1 604 9045714 KI...

Страница 15: ...cm 1 5 pulg de diámetro Corriente de entrada 120 V 60 Hz 1 8 A sólo corr alt Peso neto sólo compresor 8 9 Kg 19 6 lbs GARANTÍA LIMITADA DE UN AÑO DE CRAFTSMAN DURANTE UN AÑO a partir de la fecha de compra este producto está garantizado contra defectos de material o mano de obra Presentando el comprobante de compra el producto defectuoso se sustituirá o reparará según el criterio del vendedor Para ...

Страница 16: ...AD PERSONAL Al cargar utilizar y dar servicio a esta herramienta el operador y demás personas SIEMPRE deben llevar puesta protección ocular que cumpla con las especificaciones ANSI y ofrezca protección contra partículas que salgan disparadas del FRENTE y de los LADOS Se requiere protección ocular como protección contra sujetadores y desechos que salgan disparados los cuales pueden causar lesiones ...

Страница 17: ...iones señaladas en la sección Mantenimiento de este manual El empleo de piezas no autorizadas o el incumplimiento de las instrucciones de mantenimiento puede significar un riesgo de lesiones REGLAS DE SEGURIDAD ESPECÍFICAS Lea el manual del operador Familiarícese con su herramienta eléctrica Lea cuidadosamente el manual del operador Aprenda sus usos y limitaciones así como los posibles peligros es...

Страница 18: ...orales serias No utilice este compresor de aire para rociar productos químicos Pueden resultar afectados los pulmones debido a la inhalación de emanaciones tóxicas Puede ser necesario utilizar un respirador en entornos polvorientos o al rociar pintura No acarree la unidad mientras esté pintando Inspeccione periódicamente los cordones eléctricos y las mangueras de las herramientas y si están dañado...

Страница 19: ... el recalentamiento del motor Si el compresor no funciona al conectarlo en una toma de corriente vuelva a revisar el suministro de corriente VELOCIDAD Y CABLEADO 1 La velocidad en vacío del motor eléctrico varía por el modelo y la especificación La velocidad del motor no es constante y disminuye durante el corte o con un voltaje bajo En cuanto al voltaje el cableado de un taller es tan importante ...

Страница 20: ... comprimido mediante un pistón de vaivén contenido dentro del cilindro Manómetro regulador Muestra la presión actual en el conducto La presión del conducto se ajusta girando la perilla de regulación de presión Válvula de seguridad Su función es impedir que la presión del aire ascienda más allá de un límite predeterminado PCEPM Pies Cúbicos Estándar Por Minuto La unidad de medida de suministro de a...

Страница 21: ...terior a través de la válvula de escape al tubo de descarga a través de la válvula de retención antirretorno y al interior del tanque de aire Interruptor de encendido apagado Este interruptor se usa para arrancar o parar apagar el compresor de aire Al moverlo a la posición ON encendido se suministra alimentación automática al interruptor de presión lo que permitirá que el motor arranque cuando la ...

Страница 22: ...einiciar el compresor de aire Apague el compresor de aire Desconecte el compresor de aire y déjelo enfriar durante 30 minutos Conecte el compresor a una toma aprobada Encienda el compresor Toma del filtro de aire Este filtro está diseñado para limpiar el aire que entra en la bomba y no requiere mantenimiento si funciona de acuerdo con las advertencias e instrucciones de funcionamiento indicadas en...

Страница 23: ...al y las instrucciones del fabricante de la herramienta de aire señaladas en el manual de la misma Si utiliza un dispositivo de inflado con un racor de conexión rápida controle la cantidad de caudal de aire con el botón del regulador de la presión Si gira el botón por completo en sentido contrario a las agujas del reloj el caudal de aire se detendrá totalmente NOTA Siempre use la cantidad de presi...

Страница 24: ...manera que la válvula se encuentre en la posición más baja Abra la válvula de drenaje girando la manilla de la válvula de drenaje a la izquierda en 1 4 de vuelta Fig 8 Mantener el compresor inclinado hasta que todo el líquido y el condensado de vapor hayan sido drenados en un contenedor apropiado NOTA El condensado es material contaminante debe desecharse de conformidad con los reglamentos locales...

Страница 25: ...as que se utilizan en materiales de fibra de vidrio paneles de yeso para paredes compuestos de resanar o yeso están sujetas a desgaste acelerado y posible fallo prematuro porque las partículas y limaduras de fibra de vidrio son altamente abrasivas para los cojinetes escobillas conmutadores etc Por consiguiente no recomendamos el uso de esta herramienta durante períodos prolongados de trabajo en es...

Страница 26: ...ctor contra sobrecarga térmica interrumpe la corriente continuamente 1 Voltaje baio 2 Ventilación insuficiente temperatura ambiental demasiado elevada 3 Cordón de extensión de calibre o longitud equivocados 1 Revise con voltímetro 2 Lleve el compresor a un lugar bien ventilado 3 Verifique que el calibre y la longitud del cable sean los correctos La presión del aparato receptor del aire desciende c...

Страница 27: ...27 ...

Страница 28: ...stas a preguntas o problemas y ordenar piezas o pedir servicio para la reparación de su equipo To help us help you register your product at www craftsman com registration Para poderte ayudar mejor registra tu producto en www craftsman com registration Join the Craftsman Club today Receive exclusive member benefits including special pricing and offers project sharing expert advice and SHOP YOUR WAY...