background image

10

HOW TO USE YOUR AIR COMPRESSOR

See figures 5 - 6.

Do not allow familiarity with tools to make 

you careless. Remember that a careless fraction of a second 

is sufficient to inflict serious injury.

Always wear safety goggles or safety 

glasses with side shields when operating power tools. Failure 

to do so could result in objects being thrown into your eyes 

resulting in possible serious injury.

Do not use in an environment that is dusty or 

otherwise contaminated. Using the air compressor in this type 

of environment may cause damage to the unit.

  Ensure the tank drain valve is closed (see fig. 5).

  Ensure the ON/OFF switch is in the 

OFF (O)

 position and the 

air compressor is unplugged (see fig. 5).

  Ensure the pressure regulator knob is turned fully 

counterclockwise (see fig. 5).

WARNING

WARNING

CAUTION

Always ensure the switch is in the 

OFF 

(O)

 position and the regulator pressure gauge reads zero 

before changing air tools or disconnecting the hose from the 

air outlet. Failure to do so could result in possible serious 

personal injury.

  Connect the power cord to the power supply.
  Turn the ON/OFF switch to the 

ON (I)

 position.

  Rotate the pressure regulator knob to the desired line 

pressure. Turning the knob clockwise increases air pressure 

at the outlet; turning the knob counterclockwise reduces air 

pressure at the outlet.

 

NOTE:

 Before connecting or disconnecting air tools, turn the 

regulator knob counterclockwise to stop the flow of air.

  Following all safety precautions in this manual and the 

manufacturer’s instructions in the air tool manual. You may 

now use your air-powered tool.

  If using an inflation accessory with a quick-connect fitting, 

control the amount of air flow with the pressure regulator knob. 

Turning the knob fully counterclockwise will completely stop 

the flow of air.

 

NOTE:

 Always use the minimum amount of pressure 

necessary for your application. Using a higher pressure than 

needed will drain air from the tank more rapidly and cause the 

unit to cycle on more frequently.

  When finished, always drain the tank and unplug the unit. 

Never leave the unit plugged in and/or running unattended.

Check the air tool manual to insure the 

correct air pressure regulator setting for optimum operation of 

your air tools. If you are using an air tool not originally included 

with the air tool kit supplied with this air compressor, your tool 

may require more air consumption than this air compressor is 

designed to supply. 

Always read your air tool owner’s manual to match the correct 

air supply to your air tool to avoid damage to the tool or risk of 

personal injury.

 

NOTE:

 Do not exceed 50% duty cycle - 5 minutes ON and 5 

minutes OFF.

WARNING

WARNING

  If not already installed, attach the hose to the compressor.
  Apply thread sealing tape to male threaded end of the male 

connector fitting. Attach 1/4 in. NPT male connector fitting to 

accessory or tool you intend to use (see fig. 6).

Drain 

valve

Pressure 

regulator knob

On/Off 

switch

Fig. 5

Coil hose  

with quick 

coupler 

attached

1/4 in. male 

connector 

fitting

Blow gun

Thread 

sealing 

tape

Long inflation 

chuck

Fig. 6

Inflation  

accessories

  Connect the air powered tools to the air hose by inserting the 

male quick-connect plug to the quick-coupler at the end of the 

hose (see fig. 6).

TIRE GAUGE 

(see figure 7)

Operating instructions:

1.  Press gauge firmly onto valve stem.

2.  Read PSI on indicator bar.

3.  Adjust pressure to manufacturer’s specifications.

4.  Push indicator bar back into gauge.

  Always keep your tires inflated to manufacturer’s 

recommended pressure.

  Check pressure when tire is cold.

  Proper inflation helps prevent blowouts, increases gas mileage 

and prolongs tire life.

Fig. 7

Содержание 107.10265

Страница 1: ... and follow all its Safety Rules and Operating Instructions AIR COMPRESSOR Safety Instructions Assembly Operation Maintenance Troubleshooting Guide Storage Parts List Español p 15 Model No 107 10265 2 Gallon Oil Free Portable Air Compressor 12 15 2014 Part No 9041424 ...

Страница 2: ...uct will be repaired or replaced at option of seller For warranty coverage details to obtain free replacement visit the web page www craftsman com warranty This warranty does not cover inflation nozzles or needles sealing tape or the hose which are expendable parts that can wear out from normal use within the warranty period This ONE YEAR warranty is void if this product is ever used while providi...

Страница 3: ...orms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when loading operating or servicing this tool Eye protection is required to guard against flying fasteners and debris which could cause severe eye injury The employer and or user must ensure that proper eye protection is worn We...

Страница 4: ...ill not be used for a while it is best to leave the drain valve open until such time as it is to be used This will allow moisture to com pletely drain out and help prevent corrosion on the inside of tank WARNING Check hoses for weak or worn condition before each use making certain all connections are secure Do not use if a defect is found Purchase a new hose or take to a qualified service center f...

Страница 5: ... mask if the operation is dusty Following this rule will reduce the risk of serious personal injury Do not use this air compressor to spray chemicals Your lungs can be damaged by inhaling toxic fumes A respirator may be necessary in dusty environments or when spraying paint Do not carry while painting Inspect tool cords and hoses periodically and if damaged have repaired at a qualified service cen...

Страница 6: ...e a loss of power and the motor will overheat If the air compressor does not operate when plugged into an outlet double check the power supply SPEED AND WIRING 1 The no load speed of the electric motor varies by model and specification The motor speed is not constant and decreases under a load or with lower voltage For voltage the wiring in a shop is as important as the motor s horsepower rating 2...

Страница 7: ...Pump Produces the compressed air with a reciprocating piston contained within the cylinder Regulator Pressure Gauge Outlet pressure Displays the current line pressure Line pressure is adjusted by rotating the pressure regulator knob Safety Valve Prevents air pressure in the air tank from rising over a predetermined limit SCFM Standard Cubic Feet Per Minute A unit of measure of air delivery L min L...

Страница 8: ...oses and compressed air is forced out through the exhaust valve into the discharge line through the check valve and into the air tank On Off power switch This switch is used to start or stop the air compressor Moving the switch to the ON position will provide automatic power to the pressure switch which will allow the motor to start when the air tank pressure is below the factory set cut in pressu...

Страница 9: ...wrong gauge wire used To reset the air compressor Turn the air compressor off Unplug the air compressor and allow it to cool for 30 minutes Plug the air compressor into an approved outlet Turn the air compressor on Air filter intake This filter is designed to clean air coming into the pump and requires no maintenance when operated in accordance with the warnings and operating instruction outlined ...

Страница 10: ...g the knob fully counterclockwise will completely stop the flow of air NOTE Always use the minimum amount of pressure necessary for your application Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently When finished always drain the tank and unplug the unit Never leave the unit plugged in and or running unattended Check the ai...

Страница 11: ... loosened from this device could fly up and hit you Failure to heed this warning could result in death or serious personal injury The safety valve will automatically release air if the air receiver pressure exceeds the preset maximum The valve should be checked before each day of use by pulling the ring by hand Turn the air compressor on and allow the tank to fill The compressor will shut off when...

Страница 12: ...y plastic which may result in serious personal injury Electric tools used on fiberglass material wall board spackling compounds or plaster are subject to accelerated wear and possible premature failure because the fiberglass chips and grindings are highly abrasive to bearings brushes commutators etc Consequently we do not recommend using this tool for extended work on these type of materials Howev...

Страница 13: ...or to a service center The thermal overload protector cuts out repeatedly 1 The voltage from the power supply is low 2 A poorly ventilated room is causing the motor to overheat 3 The gauge wire or the length of extension cord is wrong 1 Check the voltage with a voltmeter 2 Move the compressor to well ventilated area 3 Check for proper gauge wire and cord length The air receiver pressure drops when...

Страница 14: ...5 SWITCH SUPPORT 1 502 9052125 GAUGE 1 503 9053408 T CONNECTOR 1 505 9064821 LOCK CABLE 1 506 9101978 SCREW TCEI M6x14 4 507 9142591 SCREW PARKER 3 9x16 2 508 9101305 SCREW TCEI M6x25 2 509 9103525 SCREW TSEI 4x12 2 510 9104153 SCREW M3x6 2 PUMP 9417263 PUMP 1 601 9045721 25 COIL HOSE 1 602 9045805 BLOW GUN 1 603 9045806 KIT QUICK CONN PTFE THREAD SEALING TAPE LONG INFLATION CHUCK 1 604 9045714 KI...

Страница 15: ...cm 1 5 pulg de diámetro Corriente de entrada 120 V 60 Hz 1 8 A sólo corr alt Peso neto sólo compresor 8 9 Kg 19 6 lbs GARANTÍA LIMITADA DE UN AÑO DE CRAFTSMAN DURANTE UN AÑO a partir de la fecha de compra este producto está garantizado contra defectos de material o mano de obra Presentando el comprobante de compra el producto defectuoso se sustituirá o reparará según el criterio del vendedor Para ...

Страница 16: ...AD PERSONAL Al cargar utilizar y dar servicio a esta herramienta el operador y demás personas SIEMPRE deben llevar puesta protección ocular que cumpla con las especificaciones ANSI y ofrezca protección contra partículas que salgan disparadas del FRENTE y de los LADOS Se requiere protección ocular como protección contra sujetadores y desechos que salgan disparados los cuales pueden causar lesiones ...

Страница 17: ...iones señaladas en la sección Mantenimiento de este manual El empleo de piezas no autorizadas o el incumplimiento de las instrucciones de mantenimiento puede significar un riesgo de lesiones REGLAS DE SEGURIDAD ESPECÍFICAS Lea el manual del operador Familiarícese con su herramienta eléctrica Lea cuidadosamente el manual del operador Aprenda sus usos y limitaciones así como los posibles peligros es...

Страница 18: ...orales serias No utilice este compresor de aire para rociar productos químicos Pueden resultar afectados los pulmones debido a la inhalación de emanaciones tóxicas Puede ser necesario utilizar un respirador en entornos polvorientos o al rociar pintura No acarree la unidad mientras esté pintando Inspeccione periódicamente los cordones eléctricos y las mangueras de las herramientas y si están dañado...

Страница 19: ... el recalentamiento del motor Si el compresor no funciona al conectarlo en una toma de corriente vuelva a revisar el suministro de corriente VELOCIDAD Y CABLEADO 1 La velocidad en vacío del motor eléctrico varía por el modelo y la especificación La velocidad del motor no es constante y disminuye durante el corte o con un voltaje bajo En cuanto al voltaje el cableado de un taller es tan importante ...

Страница 20: ... comprimido mediante un pistón de vaivén contenido dentro del cilindro Manómetro regulador Muestra la presión actual en el conducto La presión del conducto se ajusta girando la perilla de regulación de presión Válvula de seguridad Su función es impedir que la presión del aire ascienda más allá de un límite predeterminado PCEPM Pies Cúbicos Estándar Por Minuto La unidad de medida de suministro de a...

Страница 21: ...terior a través de la válvula de escape al tubo de descarga a través de la válvula de retención antirretorno y al interior del tanque de aire Interruptor de encendido apagado Este interruptor se usa para arrancar o parar apagar el compresor de aire Al moverlo a la posición ON encendido se suministra alimentación automática al interruptor de presión lo que permitirá que el motor arranque cuando la ...

Страница 22: ...einiciar el compresor de aire Apague el compresor de aire Desconecte el compresor de aire y déjelo enfriar durante 30 minutos Conecte el compresor a una toma aprobada Encienda el compresor Toma del filtro de aire Este filtro está diseñado para limpiar el aire que entra en la bomba y no requiere mantenimiento si funciona de acuerdo con las advertencias e instrucciones de funcionamiento indicadas en...

Страница 23: ...al y las instrucciones del fabricante de la herramienta de aire señaladas en el manual de la misma Si utiliza un dispositivo de inflado con un racor de conexión rápida controle la cantidad de caudal de aire con el botón del regulador de la presión Si gira el botón por completo en sentido contrario a las agujas del reloj el caudal de aire se detendrá totalmente NOTA Siempre use la cantidad de presi...

Страница 24: ...manera que la válvula se encuentre en la posición más baja Abra la válvula de drenaje girando la manilla de la válvula de drenaje a la izquierda en 1 4 de vuelta Fig 8 Mantener el compresor inclinado hasta que todo el líquido y el condensado de vapor hayan sido drenados en un contenedor apropiado NOTA El condensado es material contaminante debe desecharse de conformidad con los reglamentos locales...

Страница 25: ...as que se utilizan en materiales de fibra de vidrio paneles de yeso para paredes compuestos de resanar o yeso están sujetas a desgaste acelerado y posible fallo prematuro porque las partículas y limaduras de fibra de vidrio son altamente abrasivas para los cojinetes escobillas conmutadores etc Por consiguiente no recomendamos el uso de esta herramienta durante períodos prolongados de trabajo en es...

Страница 26: ...ctor contra sobrecarga térmica interrumpe la corriente continuamente 1 Voltaje baio 2 Ventilación insuficiente temperatura ambiental demasiado elevada 3 Cordón de extensión de calibre o longitud equivocados 1 Revise con voltímetro 2 Lleve el compresor a un lugar bien ventilado 3 Verifique que el calibre y la longitud del cable sean los correctos La presión del aparato receptor del aire desciende c...

Страница 27: ...27 ...

Страница 28: ...stas a preguntas o problemas y ordenar piezas o pedir servicio para la reparación de su equipo To help us help you register your product at www craftsman com registration Para poderte ayudar mejor registra tu producto en www craftsman com registration Join the Craftsman Club today Receive exclusive member benefits including special pricing and offers project sharing expert advice and SHOP YOUR WAY...

Отзывы: