10. Testing Your Fan.
page 9
motor housing
diagram 1
diagram 2
diagram 3
diagram 4
It is recommended that you test fan before
finalizing installation. Restore power from
circuit box and light switch (if applicable). Test
fan speeds with the pull chain located to the
right of reverse switch. Start at the OFF
position (no blade movement). First pull will
set the fan to HI. Second pull will set the fan to
MEDIUM. Third pull will set the fan to LOW.
Fourth pull will again set the fan to the OFF
setting. Test light with the pull chain located
to the left of reverse switch. (
diagram 1
). If fan
and/or light do (does) not function, please
refer to “Troubleshooting" section to solve
any issues before contacting Customer
Service.
Turn fan completely off
before
moving the
reverse switch (located on the light kit). Set
reverse switch to recirculate air depending on
the season:
- LEFT position in summer (
diagram 2)
- RIGHT position in winter (
diagram 3)
A ceiling fan will allow you to raise your
thermostat setting in summer and lower your
thermostat
setting in winter without feeling a difference
in
your comfort.
IMPORTANT
: Reverse switch must be set
either
completely LEFT
or
completely RIGHT
for
fanto function. If the reverse switch is set in
the
middle
position (
diagram 4
), fan will not
operate.
Attach pull chain extensions supplied or
custom pull chain extensions (sold separately)
to ends of the pull chains.
light
pull chain
extension
fan
pull chain
extension
reverse switch