5. Fan Assembly.

Remove blade arm screws and lock washers from 
underside of motor in order to remove blue motor 
stabilization plate. (Blue motor stabilization plate 
may be discarded once removed but 

save blade arm 

screws and lock washers to secure blade arms)

. [

Refer 

to 

diagram 1

.

]

Remove hanging ball from downrod provided by 
loosening set screw on hanging ball. Lower hanging 
ball and remove stop pin and then slide hanging 
ball off of the downrod. [

Refer to 

diagram 2

.

]

Loosen yoke set screws and nuts at top of motor 
housing. Remove pin and clip from motor housing 
yoke. [

Refer to 

diagram 3

.

]

Tip

: To prepare for threading electrical wires 

through downrod, apply a small piece of electrical 
tape to the ends of the electrical wires--this will 
keep the wires together when threading them 
through the downrod. [

Refer to 

diagram 3

.

]

Determine the length of downrod you wish to use. 
Thread safety cable and electrical wires through 
threaded end of downrod and pull extra wire slack 
from the upper end of the downrod. [

Refer to 

diagram 3

.

Thread downrod into the motor housing yoke until 
holes for pin and clip in downrod align with holes in 
yoke--

make sure wires do not get twisted

. Re-insert 

pin and clip that were previously removed. Tighten 
yoke set screws and nuts securely. [

Refer to 

diagram 3

.

]

 
Locate canopy cover in hardware pack. Slide yoke 
cover, canopy cover and canopy over downrod.  
[

Refer to 

diagram 4

.

] (

Note

: Canopy cover must be 

turned with shiny side 

toward

 the motor housing.)

["Fan Assembly"  continued on next page.]

stabilization

plate

set screw

hanging ball

stop pin

diagram 2

diagram 1

diagram 3

motor
housing

canopy

canopy cover

downrod

yoke

cover

downrod

electrical wiring

yoke set screw 
and nut

pin

clip

motor
housing

safety cable

diagram 4

Содержание SAP62

Страница 1: ...king Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Switch Housing Assembl...

Страница 2: ...an for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked suitable for use w...

Страница 3: ...Check against parts inventory that all parts have been included IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety g j i k a canopy 1 piece b hanging b...

Страница 4: ...anging bracket to outlet box using original screws spring washers and flat washers provided with new or original outlet box If installing on a vaulted ceiling face opening of hanging bracket towards h...

Страница 5: ...threading them through the downrod Refer to diagram 3 Determine the length of downrod you wish to use Thread safety cable and electrical wires through threaded end of downrod and pull extra wire slac...

Страница 6: ...the hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or...

Страница 7: ...ng wires are different colors than those referred to below please use a qualified electrician Note Excess lead wire length from the fan can be cut to the desired length and then stripped When downrod...

Страница 8: ...arm holes with motor screw holes and attach one blade arm with lock washers and blade arm screws Before securing screws permanently repeat procedure with remaining blade arms Securely tighten all scre...

Страница 9: ...an completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diagram 3 A ceiling fan will...

Страница 10: ...E will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Craftm...

Страница 11: ...1 Desempaquetado del ventilador P g 2 Inventario de piezas P g 2 Preparaci n para la instalaci n P g 3 Instalaci n del soporte de montaje P g 3 Ensamblaje del ventilador P gs 4 5 Instalaci n el ctrica...

Страница 12: ...cual corresponda cada uno consultar con un electricista para informarse sobre el tama o correcto de conectores para cable que se debe usar 5 Los diagramas el ctricos son nicamente para referencia Los...

Страница 13: ...n todas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a e b c d f h g j i k a cubierta decorativa 1 unidad b sopo...

Страница 14: ...es las arandelas de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalaci n en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la p...

Страница 15: ...ama 2 Determinar el largo del tubo que desea usar Pasar los cables del ventilador y el cable de seguridad a trav s del extremo del tubo que tenga rosca y con cuidado jalar el cableado en exceso por la...

Страница 16: ...ola se alinee con la parte saliente del soporte de montaje ADVERTENCIA el no alinear la ranura en la bola que sirve para colgar con la parte saliente del soporte de montaje puede causar lesiones grave...

Страница 17: ...que la caja de salida est conectada a tierra como es debido y que exista un conductor a tierra VERDE o pelado Asegurarse de que toda conexi n el ctrica cumpla con los C digos y las Ordenanzas Locales...

Страница 18: ...s aspas Apretar bien todos los tornillos Nota apretar los tornillos para los brazos para las aspas dos veces al a o 9 Instalaci n de la caja de encendido placa de la caja de encendido caja de encendid...

Страница 19: ...n se APAGAR el ventilador de nuevo diagrama 1 Si el ventilador no funciona favor de referirse a la secci n Localizaci n de fallas para resolver cualquier asunto antes de comunicarse con el Servicio a...

Страница 20: ...liente de CRAFTMADE al 1 800 486 4892 para acordar el reenv o del ventilador Devolver el ventilador con los gastos de env o prepagados a Craftmade Nosotros repararemos o reemplazaremos el ventilador y...

Отзывы: