background image

SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit 

panel before you begin the fan installation or before servicing the fan or installing accessories.

1.        

 READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND 

SAVE THESE INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and 

ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are different 
colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least 

seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.  The fan should be 
mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other 
upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 

pounds (16 kilograms).  The outlet box must be supported directly by the building structure.  Use only CUL 
(Canada) or UL (USA) listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable 

for Fan Support of 15.9 kg (35 lbs.) or less,"  and use the mounting screws provided with the outlet box.  Most outlet 
boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be 
replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are 

designed to accept only one12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 
gauge or there is more than one house wire to connect to the corresponding fan lead wires, consult an electrician for 
the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be CUL (Canada) or 

UL (USA) listed and marked suitable for use with the model fan you are installing.  Switches must be CUL 
(Canada) or UL (USA) general use switches.  Refer to the instructions packaged with the light kits and 
switches for proper assembly.  

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into 

the outlet box.  The wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of electrical shock or fire, do not use this fan with any solid state speed control device 

or control fan speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will 
cause a loud humming noise from fan.] (

Note

: This fan 

is

 suitable for use with remote control approved for use in 

DAMP locations.

8.        Do not operate the reverse switch until fan has come to a complete stop.
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do 

not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or 

cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth 

will be suitable for most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts OTHER than 

those provided with this fan will void the warranty.

WARNING

:  

This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable 

provided may result in personal injury, damage to the fan or damage to other property.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all 

possible conditions and situations that may occur.  It must be understood that common sense and caution are 
necessary factors in the installation and operation of this fan.

Содержание SAP62

Страница 1: ...king Your Fan pg 2 Parts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Switch Housing Assembl...

Страница 2: ...an for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked suitable for use w...

Страница 3: ...Check against parts inventory that all parts have been included IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety g j i k a canopy 1 piece b hanging b...

Страница 4: ...anging bracket to outlet box using original screws spring washers and flat washers provided with new or original outlet box If installing on a vaulted ceiling face opening of hanging bracket towards h...

Страница 5: ...threading them through the downrod Refer to diagram 3 Determine the length of downrod you wish to use Thread safety cable and electrical wires through threaded end of downrod and pull extra wire slac...

Страница 6: ...the hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or...

Страница 7: ...ng wires are different colors than those referred to below please use a qualified electrician Note Excess lead wire length from the fan can be cut to the desired length and then stripped When downrod...

Страница 8: ...arm holes with motor screw holes and attach one blade arm with lock washers and blade arm screws Before securing screws permanently repeat procedure with remaining blade arms Securely tighten all scre...

Страница 9: ...an completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diagram 3 A ceiling fan will...

Страница 10: ...E will repair or replace at no charge to the original purchaser any fan motor that fails to operate satisfactorily when failure results from normal use RETURN FAN MOTOR ONLY shipping prepaid to Craftm...

Страница 11: ...1 Desempaquetado del ventilador P g 2 Inventario de piezas P g 2 Preparaci n para la instalaci n P g 3 Instalaci n del soporte de montaje P g 3 Ensamblaje del ventilador P gs 4 5 Instalaci n el ctrica...

Страница 12: ...cual corresponda cada uno consultar con un electricista para informarse sobre el tama o correcto de conectores para cable que se debe usar 5 Los diagramas el ctricos son nicamente para referencia Los...

Страница 13: ...n todas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a e b c d f h g j i k a cubierta decorativa 1 unidad b sopo...

Страница 14: ...es las arandelas de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalaci n en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la p...

Страница 15: ...ama 2 Determinar el largo del tubo que desea usar Pasar los cables del ventilador y el cable de seguridad a trav s del extremo del tubo que tenga rosca y con cuidado jalar el cableado en exceso por la...

Страница 16: ...ola se alinee con la parte saliente del soporte de montaje ADVERTENCIA el no alinear la ranura en la bola que sirve para colgar con la parte saliente del soporte de montaje puede causar lesiones grave...

Страница 17: ...que la caja de salida est conectada a tierra como es debido y que exista un conductor a tierra VERDE o pelado Asegurarse de que toda conexi n el ctrica cumpla con los C digos y las Ordenanzas Locales...

Страница 18: ...s aspas Apretar bien todos los tornillos Nota apretar los tornillos para los brazos para las aspas dos veces al a o 9 Instalaci n de la caja de encendido placa de la caja de encendido caja de encendid...

Страница 19: ...n se APAGAR el ventilador de nuevo diagrama 1 Si el ventilador no funciona favor de referirse a la secci n Localizaci n de fallas para resolver cualquier asunto antes de comunicarse con el Servicio a...

Страница 20: ...liente de CRAFTMADE al 1 800 486 4892 para acordar el reenv o del ventilador Devolver el ventilador con los gastos de env o prepagados a Craftmade Nosotros repararemos o reemplazaremos el ventilador y...

Отзывы: