Bulb Replacement
(use 7C7 night light replacement lamps)
Remove screws from top flange cover. Lift cover up exposing inside
motor housing. Uscrew bulb holder and lift holder from housing. Replace
bulb and screw bulb holder back into motor housing. Lower top flange
cover and replace screws.
Motor Housing (7)
Flange Cover (#4)
15
16
Electrical Connections
Connect black and blue (if provided) fan wires to black outlet wire. Connect
white fan wire to white outlet wire and green grounding lead wire from the
grounding conductor to the supply circuit (see figure A). Use wire connectors
provided with your fan. No loose strands or loose connections should be
present. After wires have been connected, they must be spread apart so the
green and white are on one side of the outlet box and the black and blue
are on the other side. Turn splices upward and carefully push all wiring into
outlet box. For optional wall control see figure B or Figure C for alternate
wiring. When wall switches are employed, switches should be UL listed for
use with ceiling fan.
NOTE:
Make sure fan on/off switch is always at "high speed" location if your fan is
controlled by additional wall switch.
Ground
Black
White
White
Green
Optional Light
Black
Blue
Light Switch
Figure B
16
Electrical Connections
Ground
Black
White
Blue
Black
White
Green
Optional Light
Figure A