page 7
7. Wiring.
WARNING
: Turn off circuit breakers to current
fixture from breaker panel and be sure switch is
turned to the OFF position.
CAUTION
:
Be sure outlet box is properly grounded
and that a ground wire (
GREEN
or Bare) is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code. If you are unfamiliar with electrical
wiring or if the house/building wires are different
colors than those referred to below, please use a
qualified electrician.
Note
:
Excess lead wire length from the fan can
be cut to the desired length and then stripped.
When downrod is secured in place on the
hanging bracket, electrical wiring can be made
as follows:
Connect
BLACK
and
BLUE
wire from fan to
BLACK
wire from ceiling with wire connector
provided.
Connect
WHITE
wire from fan to
WHITE
wire
from ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together
from fan to
BARE
/
GREEN
wire from ceiling
with wire connector provided.
If you intend to control the fan light with a
separate light switch, connect
BLUE
wire from
fan to the
BLACK
(or
RED
) supply from the
independent switch.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
This fan is remote control adaptable (remote
control sold separately).
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
*
from
ceiling
from
fan
ground
(green or bare)
8. Canopy Assembly.
Raise canopy to hanging bracket, aligning
loosened screws in hanging bracket with
slotted holes in canopy. Twist canopy to lock.
Re-insert screws (with star washers) that were
previously removed (on page 4, Section 4)
and then secure all screws with a Phillips
screwdriver.
canopy
hanging bracket
slotted
hole