background image

3. Installation Preparation.

4. Hanging Bracket Installation.

page 3

ON

OFF

ON

OFF

Vaulted ceiling 
angle is not to 
exceed 25 degrees.  

downrod

installation

flushmount

installation

12f

t.

 - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

blade edge

7 feet

(2.13m)

(76cm)

30 

inches

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7ft. (2.13m) from the floor and 30in. 
(76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 400 square 
feet (37.2 square meters).

Installation requires these tools:

Phillips screwdriver, flat-head screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

Turn off circuit breakers to current fixture from 
breaker panel and be sure operating light switch is 
turned to the OFF position.

WARNING: 

Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture.

WARNING:

 When using an existing outlet box, be sure 

the outlet box is securely attached to the building 
structure and can support the full weight of the fan. 
Ensure outlet box is clearly marked "Suitable for Fan 
Support." If not, it must be replaced with an approved 
outlet box. Failure to do so can result in serious injury.

CAUTION

Be sure outlet box is grounded properly and 

that a ground wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers  provided 
with new or original outlet box.

*

 If installing on a 

vaulted ceiling, face opening of hanging bracket 
towards high point of ceiling. Arrange electrical 
wiring around the back of the hanging bracket and 
away from the hanging bracket opening.

*Note

: It is very important that you use the proper 

hardware when installing the hanging bracket as this 
will support the fan. 

hanging bracket

spring washers

outlet box screws

flat washers

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling. The 
hanging length can be extended by purchasing 
a longer downrod (0.5in. /1.27cm diameter). 
Other installation, such as 

flushmount

, is 

NOT

 

available for this fan.

Содержание Civic Unipack CIU52

Страница 1: ... Light Kit Assembly pg 7 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 18 83 lb 8 54 kg PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE E192641 Civic Unipack Federal regulations require ceiling fans with light kits manufactured or imported after January 1 2009 to limit total wattage consumed by the light kit to 190W Therefor...

Страница 2: ...12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CETL or CUL listed Canada or ETL or UL listed USA and marked suitable for use with the model fan you are installing Switches must be CETL or CUL...

Страница 3: ...cluded 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c 6in downrod and hanging ball 1 piece d 2in downrod 1 piece e motor housing 1 piece f yoke cover 1 piece g light kit fitter 1 piece h blade arm 5 pieces i blade 5 pieces j hardware packs a e f g b c IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety h d j i required bulbs 2 x 40 wa...

Страница 4: ...utlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure outlet box is clearly marked Suitable for Fan Support If not it must be replaced with an approved outlet box Failure to do so can result in serious injury CAUTION Be sure outlet box is grounded properly and that a ground wire GREEN or bare is present Install hanging bra...

Страница 5: ...hten yoke set screws and nuts securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of downrod and raise hanging ball Be sure stop pin aligns with...

Страница 6: ...port the fan you are now ready to hang your fan Grab the fan firmly with two hands Slide downrod through opening in hanging bracket and let hanging ball rest on the hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another pers...

Страница 7: ...s Insert 3 blade attachment screws along with washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Remove blade arm screws and lock washers from underside of motor If plastic motor locks are installed with blade arm screws discard plastic motor locks save blade arm screws and lock washers to secure blade arms Align blade arm holes ...

Страница 8: ...max candelabra base bulbs included with CIU52xxx5 or two 9 watt compact flourescent GU24 bulbs included with CIU52xxx5A Important When replacing bulbs please allow bulb s and glass shade to cool down before touching them Align grooves on glass shade with nodules on inside of light kit fitter and push up gently on glass shade Twist glass shade to the RIGHT clockwise until glass shade locks into pla...

Страница 9: ... to solve any issues before contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diagram 3 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your com...

Страница 10: ...NGTON warrants this fan to the original household purchaser for indoor use under the following provisions 1 YEAR WARRANTY CRAFTMADE ELLINGTON will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Ellington Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade Ellington We will repa...

Отзывы: