WARNING

: Turn off circuit breakers to current fixture 

from breaker panel and be sure switch is turned to the 
OFF position.

CAUTION

Be sure outlet box is properly grounded and 

that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. If 
you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to in the instructions below, please use a qualified 
electrician.

Note

Excess lead wire length from the fan can be cut to 

the desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 and 

BLUE

 wires from fan to 

BLACK

 

wire from ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from fan 

to 

BARE

/

GREEN

 wire from ceiling with wire connector 

provided.

If you intend to control the fan light with a separate 
light switch, connect 

BLUE

 wire from fan  to the 

BLACK

 

(or 

RED

) supply from the independent switch.

page 5

5. Fan Assembly. (cont.)

With the hanging bracket secured to the outlet box and 
able to support the fan, you are now ready to hang your 
fan. Grab the fan firmly with two hands. Slide downrod 
through opening in hanging bracket and let hanging ball 
rest on the hanging bracket. Turn the hanging ball slot 
until it lines up with the hanging bracket tab.

WARNING

: Failure to align slot in hanging ball with tab in 

hanging bracket may result in serious injury or death.

Tip

: Seek the help of another person to hold the 

stepladder in place and to lift the fan up to you once you 
are set on the ladder.

Find a secure attachment point (wood ceiling joist highly 
recommended) and secure safety cable. It will be necessary 
to use a heavy duty wood screw, washer and lock washer 
(not supplied) with the safety cable loop. If necessary, 
adjust the loop at the end of the safety cable. The loop at 
the end of the safety cable should just fit over the threads 
on the wood screw. 

Test safety cable by pulling on loose end 

with pliers. If the safety cable slips, the loop must be adjusted 
tighter. 

Extra cable slack can be left in ceiling area. 

hanging ball slot

hanging bracket tab

safety
cable

safety cable loop

wood
ceiling
joist

wood screw

and washer

6. Wiring.

white supply wire

*

black

black

white

white

blue

black supply wire

from

ceiling

from fan

ground
(green
or bare)

ground
(green or bare)

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

This fan is remote control adaptable (remote 
control sold separately).

motor housing

Содержание Civic Unipack CIU52

Страница 1: ... Light Kit Assembly pg 7 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 net weight of fan 18 83 lb 8 54 kg PRINTED IN CHINA READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE E192641 Civic Unipack Federal regulations require ceiling fans with light kits manufactured or imported after January 1 2009 to limit total wattage consumed by the light kit to 190W Therefor...

Страница 2: ...12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CETL or CUL listed Canada or ETL or UL listed USA and marked suitable for use with the model fan you are installing Switches must be CETL or CUL...

Страница 3: ...cluded 2 Parts Inventory a canopy 1 piece b hanging bracket 1 piece c 6in downrod and hanging ball 1 piece d 2in downrod 1 piece e motor housing 1 piece f yoke cover 1 piece g light kit fitter 1 piece h blade arm 5 pieces i blade 5 pieces j hardware packs a e f g b c IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety h d j i required bulbs 2 x 40 wa...

Страница 4: ...utlet box be sure the outlet box is securely attached to the building structure and can support the full weight of the fan Ensure outlet box is clearly marked Suitable for Fan Support If not it must be replaced with an approved outlet box Failure to do so can result in serious injury CAUTION Be sure outlet box is grounded properly and that a ground wire GREEN or bare is present Install hanging bra...

Страница 5: ...hten yoke set screws and nuts securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of downrod and raise hanging ball Be sure stop pin aligns with...

Страница 6: ...port the fan you are now ready to hang your fan Grab the fan firmly with two hands Slide downrod through opening in hanging bracket and let hanging ball rest on the hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another pers...

Страница 7: ...s Insert 3 blade attachment screws along with washers with fingers first and then tighten screws securely with a Phillips screwdriver Repeat for the remaining blades Remove blade arm screws and lock washers from underside of motor If plastic motor locks are installed with blade arm screws discard plastic motor locks save blade arm screws and lock washers to secure blade arms Align blade arm holes ...

Страница 8: ...max candelabra base bulbs included with CIU52xxx5 or two 9 watt compact flourescent GU24 bulbs included with CIU52xxx5A Important When replacing bulbs please allow bulb s and glass shade to cool down before touching them Align grooves on glass shade with nodules on inside of light kit fitter and push up gently on glass shade Twist glass shade to the RIGHT clockwise until glass shade locks into pla...

Страница 9: ... to solve any issues before contacting Customer Service Turn fan completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season LEFT position in summer diagram 2 RIGHT position in winter diagram 3 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your com...

Страница 10: ...NGTON warrants this fan to the original household purchaser for indoor use under the following provisions 1 YEAR WARRANTY CRAFTMADE ELLINGTON will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Ellington Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade Ellington We will repa...

Отзывы: