6. Wiring.

CAUTION

Be sure outlet box is properly grounded 

and that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code 
(or Canadian Electrical Code). If you are unfamiliar 
with electrical wiring or if the house/building wires are 
different colors than those referred to in the diagram 
to the right, please use a qualified electrician.

WARNING

:  If using this fan in a DAMP location, this 

fan must be connected to a supply circuit that is 
protected by a Ground Fault Circuit Interrupter 
(GFCI) to reduce the risk of personal injury, electrical 
shock or death.

When downrod is secured in place on the hanging 
bracket, wire the

 RECEIVER

 with wire connectors 

provided as shown in 

diagram at right.

Tip

: While you are wiring, keep in mind that wires 

must not obstruct receiver from sliding into 
hanging bracket.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

Gently insert receiver (flat side up) into hanging 
bracket and carefully push wires and taped wire 
connectors into outlet box. Let antenna rest 

outside 

of hanging bracket.

(wiring for receiver)

IN ORDER TO WIRE WALL CONTROL

, remove existing 

wall switch. Wire the

 WALL CONTROL

 with wire 

connectors provided as shown in 

diagram at right.

* Wrap each wire connector separately with electrical 
tape as an extra safety measure. Gently push wires 
and taped wire connectors into outlet box.

Use a ballpoint pen or a small screwdriver to set the 
code switches 1 through 4 on the wall control. Factory 
setting is pre-set and not recommended for use. 

Write 

down number sequence for use in Section 10.

NOTE

: Because this fan requires compact fluorescent 

bulbs, the dimmer switch (labeled 

D

 and 

X

) has been 

pre-set to the "OFF" position (

X

). [Most compact 

fluorescent bulbs, including the ones provided with 
this fan, are not compatible for use with dimmer 
controls.]

Attach wall control to outlet box and secure with 
screws from original wall switch. Attach front plate to 
wall control using 2 screws provided in the wall 
control.

(wiring for wall control)

white supply wire

black supply wire

black

black

white

grey

blue

blue

grey

white

from receiver

black

AC IN L

AC IN N

white

whit

e

ground (green

or bare)

from fan

from receiver

antenna

from ceiling

black

receiver

ground (green

or bare)

green

black

(AC IN from

breaker box)

black (TO POWER supply)

black

green/

green/

bare 

bare 

 ground

 ground

green/

bare 

 ground

outlet box

wall

control

plate

1

2

3
4

X

D

code
switches

black (OUT to fan)

black (OUT to fan)

black (OUT to fan)

dimmer
switch

Las modificaciones no aprobadas por la parte responsable de la conformidad 
podrían invalidar la autorización del usuario para manejar el equipo. 

 

*NOTA: Se han hecho pruebas en este equipo y se ha comprobado que cumple con los límites para un 
aparato digital de clase B, de acuerdo con la Parte 15 de las Reglas de la FCC.  Se concibieron estos 
límites para proveer protección razonable contra la interferencia adversa en una instalación residencial. 
Este equipo produce, usa y puede radiar energía de radiofrecuencia y, si no se instala y no se usa según 
las instrucciones, puede causar interferencia adversa en la radiocomunicación.  Sin embargo, no hay 
ninguna garantía de que no habrá interferencia en una instalación en particular. Si este equipo sí causa 
interferencia adversa en la recepción de radio o televisión, que se puede determinar apagando y 
prendiendo el equipo, se le urge al usuario a intentar rectificar la interferencia tomando una o más de 
las medidas que siguen: 
        *      Orientar la antena de nuevo o localizarla en otro sitio. 
        *      Aumentar la separación entre el equipo y el receptor.
        *      Conectar el equipo a un tomacorriente en un circuito distinto al cual está

conectado el receptor.

Solicitar ayuda del distribuidor o un técnico de radio/televisión. 

Содержание BW248AG6

Страница 1: ...ts Inventory pg 2 Installation Preparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 7 Light Kit Assembly Optional pgs 7 8 Alternate Final Assembly Without Light Kit pg 8 Automated Learning Process Activating Code pg 9 Wall Control Operation pg 9 Remote Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replace...

Страница 2: ...wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use WARNING If using this fan in a DAMP location this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter GFCI to reduce the risk of personal injury electrical shock or death 5 Electrical diagrams are for reference only Light kits that are ...

Страница 3: ...tal cover 1 piece o finial plate pre attached to light kit fitter 1 piece p finial pre attached to light kit fitter 1 piece q motor assembly 1 piece r hardware packs 1 Unpacking Your Fan Carefully open the packaging Remove items from Styrofoam inserts Remove motor assembly and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need...

Страница 4: ...anging bracket to outlet box using original screws spring washers and flat washers provided with new or original outlet box Arrange electrical wiring around the back of the hanging bracket and away from the hanging bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support the fan To prevent personal injury and damage ensure ...

Страница 5: ...sembly yoke set screw and nut yoke cover canopy cover safety cable downrod electrical wiring If you wish to extend the hanging length of your fan you must remove the hanging ball from the 4 in downrod provided to use with an extended downrod sold separately If you wish to use the 4 in downrod please proceed to instructions following the dotted line below To remove hanging ball loosen set screw on ...

Страница 6: ...h tab in hanging bracket may result in serious injury or death CAUTION Due to the size width of this fan it is advisable to seek the help of another person to hold the stepladder in place and to then help lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will be necessary to use a heavy duty wood sc...

Страница 7: ...luorescent bulbs including the ones provided with this fan are not compatible for use with dimmer controls Attach wall control to outlet box and secure with screws from original wall switch Attach front plate to wall control using 2 screws provided in the wall control wiring for wall control white supply wire black supply wire black black white grey blue blue grey white from receiver black AC IN L...

Страница 8: ...screws Align slotted holes in large fitter plate with loosened screws in motor plate allowing molex connections from motor assembly to come through hole in middle of large fitter plate Twist large fitter plate to lock Re insert screw that was previously removed and securely tighten all 3 screws with Phillips screwdriver Remove 1 screw from post on underside of large fitter plate and partially loos...

Страница 9: ...inial plate glass shade If you do NOT wish to use the light kit remove 1 screw from motor plate on underside of motor assembly and partially loosen the other 2 screws Align slotted holes in small fitter plate with loosened screws in motor plate allowing molex connections from motor assembly to come through hole in middle of small fitter plate Twist small fitter plate to lock Re insert screw that w...

Страница 10: ...uence used when wiring the wall control in Section 6 page 6 Note Because this fan requires compact fluorescent bulbs the dimmer switch labeled D and X has been pre set to the OFF position X Most compact fluorescent bulbs including the ones provided with this fan are not compatible for use with dimmer controls Install one 12 volt battery included in transmitter Re attach battery cover on transmitte...

Страница 11: ...ons and then test rotation of fan and OFF as was done with wall control Test light with button If the remote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan light functions refer to Troubleshooting section to solve any issues before contacting Customer Service The tilt angle of the smaller f...

Страница 12: ... Solutions 1 Check to be sure set screw s on motor assembly yoke is are tightened securely 2 Check to be sure set screw on hanging ball is tightened securely WARNING Failure to disconnect power supply prior to troubleshooting any wiring issues may result in serious injury CRAFTMADE ELLINGTON LIFETIME WARRANTY CRAFTMADE ELLINGTON warrants this fan to the original household purchaser for use in damp...

Отзывы: