background image

page 4

3. Installation Preparation.

Installation requires these tools:

Phillips screwdriver, flathead screwdriver, 
adjustable pliers or wrench, stepladder, wire 
cutters, and rated electrical tape.

4. Hanging Bracket Installation.

Turn off circuit breakers to current fixture from breaker 
panel and be sure operating light switch is turned to 
the OFF position. 

WARNING

: Failure to disconnect power supply prior to 

installation may result in serious injury.

Remove existing fixture. 

WARNING

: When using an existing outlet box, be sure the 

outlet box is securely attached to the building structure 
and can support the full weight of the fan. Ensure outlet 
box is clearly marked "Suitable for Fan Support." If not, it 
must be replaced with an approved outlet box. Failure to 
do so can result in serious injury.

CAUTION

: Be sure outlet box is grounded properly and 

that a ground wire (

GREEN

 or bare) is present.

Install hanging bracket to outlet box using original 
screws, spring washers and flat washers  provided with 
new or original outlet box.

*

 If installing on a vaulted 

ceiling, face opening of hanging bracket towards high 
point of ceiling. Arrange electrical wiring around the 
back of the hanging bracket and away from the 
hanging bracket opening.

*Note

: It is very important that you use the proper 

hardware when installing the hanging bracket as this will 
support the fan. 

To prevent personal injury and damage, ensure 
that the hanging location allows the blades a 
clearance of 7 feet (2.13m) from the floor and 
30in. (76cm) from any wall or obstruction. 
This fan is suitable for room sizes up to 
400 square feet (37.2 square meters).

12f

t.

  - 20f

t.

12ft. - 20ft.

(3.66m - 6.1m)

(3.66m - 6.1m)

blade edge

7 feet

(2.13m)

(76 cm)

30 

inches

hanging bracket

spring washers

outlet box screws

flat washers

Vaulted ceiling 
angle is not to 
exceed 25 degrees.  

downrod

installation

flushmount

installation

This fan can be mounted with a 

downrod

on a regular (no-slope) or vaulted ceiling. The 
hanging length can be extended by purchasing 
a longer downrod (0.5in./1.27cm diameter). 
Other installation, such as 

flushmount

, is 

not

 

available for this fan.

Содержание Builder Deluxe BLD52-3 light

Страница 1: ...on pg 4 Hanging Bracket Installation pg 4 Fan Assembly pgs 5 6 Wiring pg 6 Canopy Assembly pg 7 Blade Attachment pg 7 Removal of Light Kit Optional pg 8 Light Kit Assembly Optional pg 9 Testing Your Fan pg 9 Troubleshooting pg 10 Parts Replacement pg 10 Warranty pg 10 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE For Model BLD52 3 light Builder Deluxe page 1 E192641 ...

Страница 2: ... and the equipment grounding conductor on opposite sides of the outlet box WARNING To reduce the risk of electrical shock or fire do not use this fan with any solid state speed control device or control fan speed with a full range dimmer switch Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan Note This fan is suitable for use with remote control 8 Do n...

Страница 3: ...iece b hanging bracket 1 piece c downrod and hanging ball 1 piece d canopy cover in hardware pack 1 piece e motor housing blade arms switch housing light kit fitter pre assembled 1 piece f socket ring pre attached to light kit fitter 3 pieces g blade 5 pieces h glass shade 3 pieces i switch housing cap 1 piece j y connect blade assembly piece 5 pieces k hardware packs page 3 a b g f h k i e c j IM...

Страница 4: ...screws spring washers and flat washers provided with new or original outlet box If installing on a vaulted ceiling face opening of hanging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the hanging bracket opening Note It is very important that you use the proper hardware when installing the hanging bracket as this will support ...

Страница 5: ... cover in hardware pack Slide canopy cover and canopy over downrod Refer to diagram 3 Note Canopy cover must be turned with shiny side toward the motor housing Thread wires through hanging ball and then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of downrod and raise hanging ball...

Страница 6: ...trical Code If you are unfamiliar with electrical wiring or if the house building wires are different colors than those referred to in the instructions please use a qualified electrician Note Excess lead wire length from the fan can be cut to the desired length and then stripped When downrod is secured in place on the hanging bracket electrical wiring can be made as follows Connect BLACK and BLUE ...

Страница 7: ...8 Blade Attachment Align holes in blade with the 3 blade screws pre installed on the blade arm Press down on the blade firmly enough so that the blade screws come through the holes in the blade CAUTION Be careful not to use so much force that the blade arm bends Place the y connect blade assembly piece on the top side of the blade so the narrower end of the y connect blade assembly piece faces tow...

Страница 8: ...re from fan to WHITE wire from light kit fitter Place wire connector that was removed on WHITE wire from fan Wrap each wire connector separately with electrical tape as an extra safety measure Remove 3 screws from switch housing cap Align holes in switch housing cap with holes in switch housing Attach switch housing cap to switch housing with 3 screws that were previously removed Attach pull chain...

Страница 9: ... completely off before moving the reverse switch Set reverse switch to recirculate air depending on the season DOWN position in summer diagram 1 UP position in winter diagram 2 A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort Important Reverse switch must be set either completely UP or c...

Страница 10: ...AR WARRANTY CRAFTMADE will replace or repair any fan which has faulty performance due to a defect in material or workmanship Contact Craftmade Customer Service at 1 800 486 4892 to arrange for return of fan Return fan shipping prepaid to Craftmade We will repair or ship you a replacement fan and we will pay the return shipping cost 5 YEAR WARRANTY CRAFTMADE will repair or replace at no charge to t...

Отзывы: