page 7
8. Canopy Assembly.
canopy ring
diagram 2
canopy
diagram 1
Remove existing wall switch.
Wire the wall control as follows, using wire
connectors provided to secure each connection:
Connect
BLACK
wire
with WHITE STRIPE
(AC IN L)
from wall control to
BLACK
(AC IN L) wire in the
outlet box.
Connect
SOLID BLACK
(TO MOTOR L) wire from
wall control to
BLACK
wire from fan in the outlet
box.
Connect
BLUE
(FOR LIGHT) wire from wall control
to
BLUE
wire from light in the outlet box.
Connect
GREEN
wire
with YELLOW STRIPE
(GROUND) from wall control to
GREEN/GROUND
wire in the outlet box.
*Wrap each wire connector separately with
electrical tape as an extra safety measure. Gently
push wires and taped wire connectors into outlet
box.
Attach wall control to outlet box and secure with
screws from original wall switch. Attach plate
(included) to wall control using 2 screws provided
with the wall control.
(wiring for wall control)
solid black
(TO MOTOR L)
blue (FOR LIGHT)
black
(AC IN L from
breaker box)
black with
white stripe
(AC IN L)
green/
green/
bare
bare
ground
ground
green/
bare
ground
outlet box
wall control
plate
blue
ound
ound
black
green with yellow
stripe (GROUND)
7. Wiring. (cont)
Temporarily raise canopy to mounting plate to
determine which 2 screws in mounting plate align
with
slotted
holes in canopy, and then lower
canopy and
partially loosen
these 2 screws.
Remove
the
other
2 screws and set aside.
Now, lift canopy to mounting plate again, aligning
slotted holes in canopy with loosened screws in
mounting plate. Twist canopy to lock. Re-insert the
other 2 screws and secure all screws with a Phillips
screwdriver. [
Refer to
diagram 1
.
]
Raise the canopy ring over the canopy until it is
even with the top of the canopy.
Note: The rubber
cushions do not go over the screws.
Make sure the
canopy and the canopy ring fit securely. [
Refer to
diagram 2
.
]
canopy
slotted
hole