Page 7 of 16
v3.1
Model
Terminal
Number
Terminal
Name
Description
P
lus
& CPM
9
Fault
These 2 terminals are normally closed, going open when a fault is
detected.
They also act as a confirmation that the test routine has started by
opening and closing after a successful completion of the test routine.
P
lus
& CPM
8
Fault
P
lus
& CPM
7
Test
A Positive signal from the control panel to start the test routine LED
P
lus
& CPM
6
Confirmed
A Negative signal from the control panel to change the Sounder and
Strobe pattern
P
lus
, s
tandard
& CPM
5
Tamper
Return
A signal from the
s
enza
to the control panel to indicate the condition
of the tamper circuit
P
lus
, s
tandard
& CPM
4
Strobe
A signal from the control panel to activate the strobe LED
P
lus
, s
tandard
& CPM
3
Siren
A signal from the control panel to activate the siren LED
P
lus
, s
tandard
& CPM
2
Hold-off
Pove A permanent positive DC supply from the control panel
P
lus
, s
tandard
& CPM
1
Hold-off
Negative 0v A permanent negative DC supply from the control panel
t
ermInal
d
eScrIptIon
dIp S
WItch
S
ettIngS
pluS
modelS
S
tandard
modelS
W
Ire
-
Free
model
1
2
3
4
5
6
7 & 8
Back-light
Tamp
Rtn
SAB/SCB
Volume
Trigger
signal
Trigger
Mon
Siren Cut-off timings
ON
ECO
Pos
Neg
SAB
SCB
Lo
Hi
Pos
Neg
ON
OFF 15 3 Int
ON
1 2 3 4 5 6 7 8
Default setting
1
2
3
4
Trigger
signal
Volume
Siren
Timing
Not Used
Pos
Neg
Lo
Hi
Int
15
ON
1 2 3 4
Default setting
1 & 2
3
4
5
6
Siren Cut-off timings
Trigger
signal
Volume
Tamper
Rtn
Not Used
15 3 Int
Pos
Neg
Lo
Hi
Pos
Neg
Default setting
ON
1 2 3 4 5 6