background image

Page 3 of 16

v3.1

This range of external warning devices includes 3 models: 2 wired at Grade 2 & 3 and 1 wire-free at Grade 2 all are 
Environmental class IV and can be installed in security systems in accordance with EN50131-1: 2006 + A1: 2009. 
The wired models comply to EN50131-4: 2009, WD type Z; the wire-free model complies to EN50131-4:2009, WD type W.  
These warning devices feature one piezo and one LED strobe for audible and visual indication of an alarm activation. 
Each model includes the latest innovation in electronics and incorporates a lithium Ion battery for better reliability, each 
of the wired versions incorporates a smart charging circuit to optimise the battery capability and battery life. 
A number of other unique features are listed below.

d

eScrIptIon

F

eatureS

 & o

ptIonS

Back-light

Only available on the PLUS version.

It is possible to select either ON or 

ECO (default).

 In the ON position the back-light is permanently ON. In the ECO 

position the inbuilt light sensor will automatically switch the back-light off during the day, thereby reducing power 

consumption.

Test

Confirmation

Only available on the PLUS and WIRE-FREE versions.

This feature allows the user to be notified before entering the premises that the intruder alarm system has generated 

a confirmed alarm due to 2 or more detectors being activated. 

During an alarm activation if a negative (0v) signal is applied to the confirmed input at the same time as a signal is 

applied to the siren input the siren tone will change to a rapid tone every few seconds. If a signal is applied to the 

strobe input, the strobe flash rate will also change. If the signal is removed from the confirmed input, the tone/flash 

rate will revert back to the standard tone/flash rate. 

If the signal is removed from the siren/strobe inputs the sounder will stop sounding/flashing regardless of a signal 

being applied to the confirmed input.

Only available on the PLUS and WIRE-FREE versions. 

If a positive signal is applied to this input it will start the test routine. At the start of the test the fault output terminals 

will go open circuit. During the test the siren will sound for 3 seconds, strobe will flash for 3 seconds and battery will 

be tested to ensure that all are functioning correctly. At the end of a successful test the Senza will make a low level 

sound and the fault output terminals will change to a closed circuit. 

If a fault is detected, the fault output terminals will stay open circuit until the fault has been rectified.

Trigger Monitoring

Only available on the PLUS version and is mandatory for all grade 3 installations. 

When selected, the device monitors the siren and strobe trigger wire’s integrity by means of monitoring resistors. 

These resistors are connected to the opposite signal that is required to activate the siren or strobe i.e. negative siren 

trigger signal (default), the monitoring resistor is connected between a positive and the trigger wire in the control 

panel.  In the event of the siren trigger wire being cut or removed, the fault output circuit will open. In the event of the 

strobe trigger wire being cut or removed the strobe will start to flash. The fault output circuit will NOT be activated. 

Note:- Fitting the resistor in the warning device does not comply with grade 3 requirements.

Engineer Hold-off

During the first installation of the Senza this feature allows you to connect the on-board battery without the sounder 

sounding, after hold-off voltage is applied the Senza will enter its normal mode. If Hold-off voltage is removed the 

sounder will sound.

Fault

Only available on the PLUS and WIRE-FREE versions. 

The 2 fault outputs are normally closed and will switch to an open circuit if a fault occurs with the sounder, strobe, and 

battery. If trigger wire monitoring has been selected the fault output will also open circuit if a fault is detected. It also 

acts as confirmation that the test procedure has been started by going open circuit and on a successful completion of 

the test procedure the outputs will go closed circuit.

Volume

Each model will allow you to select the dB(A) level required to comply with the country/regional requirements it is 

possible to reduce the sound output from 105dB(A) (

default

) to maximum sound output of 85dB(A)

Содержание Senza

Страница 1: ...e or Positive triggers Confirmation Input Fault Output Test Input Backlight option Available in Grade 2 Grade 3 or Wire free G2 only Senza Installation and Operating Instructions CQR Fire Security 125 Pasture Road Moreton Merseyside CH46 4TH United Kingdom Tel 44 0 151 606 1000 email info cqr co uk Web http www cqr co uk External Warning Device ...

Страница 2: ...B Layouts 7 Terminal Description 7 DIP Switch Settings 8 Mounting instructions 10 Wiring Connection Guide Standard Version 11 Wiring Connection Guide PLUS Version 12 Wiring Connection Guide Wirefree Version 13 Fitting Covers 14 Operating Instructions 15 Specification 16 Safety Precautions 16 Product order codes ...

Страница 3: ... the start of the test the fault output terminals will go open circuit During the test the siren will sound for 3 seconds strobe will flash for 3 seconds and battery will be tested to ensure that all are functioning correctly At the end of a successful test the Senza will make a low level sound and the fault output terminals will change to a closed circuit If a fault is detected the fault output t...

Страница 4: ... on the PLUS and WIRE FREE versions Allows you to select either a Negative signal default or a positive signal for the Tamper Return signal to match the requirements of the control panel being used Strobe Saver After 1 hour of continuous activation the strobe flash rate will be reduced from 1Hz to 0 25Hz WIRE FREE version Only During the installation of the Wire free version it is possible to chec...

Страница 5: ...ult Plus Grade 2 3 Standard Grade 2 only Tamper LED Hold off LED Strobe LED Connector for back light PCBA Connector for Battery Sounder Transformer Option switches Connection Terminals Battery Battery charging LED Tamper LED Hold off LED Strobe LED Connector for Battery Sounder Transformer Option switches Connection Terminals Battery charging LED Battery ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 ...

Страница 6: ... button Con firmed Tamper return Strobe Hold Off Pos Hold Off Neg Test Siren Fault Int 3m 15M N P Trig H L Vol N P Tamp Siren Antenna Diagnostic LEDs Tamper switch Enrolment button Option switches Connection Terminals Wire free PCB Layouts Control Panel Module CPM Grade 2 only Warning Device WD Grade 2 only Green Red ON 1 2 3 4 5 6 ...

Страница 7: ... Strobe A signal from the control panel to activate the strobe LED Plus Standard CPM 3 Siren A signal from the control panel to activate the siren LED Plus Standard CPM 2 Hold off Positive ve A permanent positive DC supply from the control panel Plus Standard CPM 1 Hold off Negative 0v A permanent negative DC supply from the control panel Terminal Description DIP Switch Settings PLUS models Standa...

Страница 8: ...the box Drill 3 holes using a 5 5mm masonry drill 41mm deep for the enclosed wall plugs insert the wall plugs into the holes fit the top centre screw enclosed leaving it protruding by 25mm Feed the cable through the cable entry point on the Senza and carefully slot the top fixing point of the Senza over the previously installed screw rotate the 2 x bottom fixing points if necessary to allow the ho...

Страница 9: ...s etc Large metal objects a distance of 1m is recommended Temporarily place the unit in the selected location do not hold ensuring that the CPM is vertical using the built in coms feature in the warning device ensure that there is communication between the warning device and the CPM see page 12 if not move the location of the CPM and repeat the process Mount the CPM in the selected location connec...

Страница 10: ...3 Plug in the battery and one bleep will be heard 4 Ensure the tamper switch will close properly and fit the lid two bleeps will be heard 5 The tamper LED should start to flash twice a second 6 This will stay like this until hold off voltage is applied or the battery goes flat 7 Connect the control panel as indicated below 8 Apply power to the Senza 9 Both the hold off LED and the tamper LED will ...

Страница 11: ...applied or the battery goes flat 7 Connect the control panel as indicated below 8 If Trigger wire monitoring is selected the 2 x 1kΩ resistors must be fitted prior to power up G3 requirement 9 Apply power to the Senza 10 Both the hold off LED and the tamper LED will now flash Two bleeps will be heard 11 After a few seconds the unit will bleep again and the LED s will flash alternately 12 After 5 m...

Страница 12: ... connections below ensuring that the DIP switches are set to your requirements The Green and Red LEDs should flash alternately 2 Connect the battery in the WD The CPM and WD should automatically pair This is indicated by the Green LED on the WD flashing every 2 seconds If not refer to Installation and operating instructions on How to pair 3 During the next 30 minutes the WD will be in engineer mod...

Страница 13: ...Page 13 of 16 v3 1 Fitting Covers Cover Lock UnLock ...

Страница 14: ...s indicates that the tamper protection for the cover and or the removal from wall is open If the Red LED stops flashing this indicates that there is no voltage on the Hold off terminals The Red battery LED is illuminated when the battery is healthy If the LED is extinguished this indicates that the battery is disconnected or faulty Wired models Please refer to the DIP switch setting on page 7 to s...

Страница 15: ...009 Warning device Type Z Warning Device WD Battery Type Lithium Manganese Dioxide non rechargeable Nominal Voltage 3 volt Capacity 4700mAh Approximate life 2 years depending on the number and duration of activations Current Consumption Quiescent 3 5mA Alarm Sounder Strobe 245mA Sounder Type Piezo Acoustic Output Tone Sound duration 15 minutes 3 minutes or intermittent Sound Output Levels 105db A ...

Страница 16: ... suffocate always dispose of packaging carefully Order code Description BCSENZ S STD W Senza S Grade 2 Backplate White BCSENZ S PLUS W Senza S Grade 2 3 Backplate White BCSENZ S PLUS L W Senza S Grade 2 3 Backplate White with Backlight BCSENZ S WF W Senza S Wirefree Kit White WD CPM BCSENZ S COV W B Senza S Cover White with Blue Lens BCSENZ S COV W B L Senza S Cover White with Blue Lens with Backl...

Отзывы: