background image

Page 12 of 16

v3.1

W

IrIng

 c

onnectIon

 g

uIde

Wirefree Version

Fault

Fault

Test

Con-

firmed

Hold-off

Pos +

Siren

Strobe

Tamper

Rtn

Hold-off

Neg -

CPM

 Connections

Connect to a 

suitable input 

within the 

control panel

Connect to a 

suitable output 

within the 

control panel

1.  Connect Hold-off Neg - 0v to 

12v - 

2.  Connect Hold-off Pos + ve to 

12v + 

3.  Connect Siren to 

OP

 

BELL

4.  Connect Strobe to 

OP

 

Strobe

5.  Connect Tamper Return to 

an input via a 2K2Ω resistor

1.  Connect Hold-off Neg - 0v to 

D

2.  Connect Hold-off Pos + ve to 

A

3.  Connect Siren to 

B

4.  Connect Strobe to 

S

5.  Connect Tamper Return to 

C

1.  Connect Hold-off Neg - 0v to 

12v com

2.  Connect Hold-off Pos + ve to 

+12v

3.  Connect Siren to 

BELL

4.  Connect Strobe to 

STRB

5.  Connect Tamper Return via a 2K2Ω resistor to 

D1

1.  Connect Hold-off Neg - 0v to 0v

2.  Connect Hold-off Pos + ve to 12v

3.  Connect Siren to Bell

4.  Connect Strobe to STB

5.  Connect Tamper Return to TR

Texecom

Pyronix

Honeywell

Scantronic

C

A

S

B

D

D1

+12V

STRB BELL

COM

TR

+12V

STB BELL

0v

Input

12V

OP

STRB

OP

BELL

12v-

Connect to a 

suitable output 

within the 

control panel

1.  Connect the 

CPM

 to the control panel as shown in the 

‘Senza CPM connections’

 below, ensuring that the DIP 

switches are set to your requirements. The Green and Red LEDs should flash alternately.

2.  Connect the battery in the 

WD

. The 

CPM

 and 

WD

 should automatically pair. This is indicated by the Green LED on 

the 

WD

 flashing every 2 seconds. If not refer to Installation and operating instructions on 

‘How to pair’.

3.  During the next 30 minutes the 

WD

 will be in engineer mode, after which it will automatically leave this mode. 

Note: if the tamper is still open the sounder will sound.

4.  Whilst the 

WD

 is in engineer mode the Green LED flashes every 2 seconds to indicate that the 

WD

 is 

communicating with the 

CPM

.

5.  Using this feature will allow you to select the best position for the 

WD

 to be installed, if the Green LED stops 

flashing it has lost communication with the 

CPM

 and should be repositioned. 

6.  The Blue LED on the 

WD

 flashing every 2 seconds indicates that the tamper is closed.

7.  To exit Engineer mode briefly apply a trigger to the Siren input of the 

CPM

 the Strobe will flash once and the 

sounder will chirp.

8.  Normal operating mode is indicated by the Green and Blue LEDs on the 

WD

 flashing alternately every 4 seconds.

Note:- Examples shown below are provided only as a guide, Control panel manufacturers may alter their notation 

from time to time and there may be differences to those shown.

Содержание Senza

Страница 1: ...e or Positive triggers Confirmation Input Fault Output Test Input Backlight option Available in Grade 2 Grade 3 or Wire free G2 only Senza Installation and Operating Instructions CQR Fire Security 125 Pasture Road Moreton Merseyside CH46 4TH United Kingdom Tel 44 0 151 606 1000 email info cqr co uk Web http www cqr co uk External Warning Device ...

Страница 2: ...B Layouts 7 Terminal Description 7 DIP Switch Settings 8 Mounting instructions 10 Wiring Connection Guide Standard Version 11 Wiring Connection Guide PLUS Version 12 Wiring Connection Guide Wirefree Version 13 Fitting Covers 14 Operating Instructions 15 Specification 16 Safety Precautions 16 Product order codes ...

Страница 3: ... the start of the test the fault output terminals will go open circuit During the test the siren will sound for 3 seconds strobe will flash for 3 seconds and battery will be tested to ensure that all are functioning correctly At the end of a successful test the Senza will make a low level sound and the fault output terminals will change to a closed circuit If a fault is detected the fault output t...

Страница 4: ... on the PLUS and WIRE FREE versions Allows you to select either a Negative signal default or a positive signal for the Tamper Return signal to match the requirements of the control panel being used Strobe Saver After 1 hour of continuous activation the strobe flash rate will be reduced from 1Hz to 0 25Hz WIRE FREE version Only During the installation of the Wire free version it is possible to chec...

Страница 5: ...ult Plus Grade 2 3 Standard Grade 2 only Tamper LED Hold off LED Strobe LED Connector for back light PCBA Connector for Battery Sounder Transformer Option switches Connection Terminals Battery Battery charging LED Tamper LED Hold off LED Strobe LED Connector for Battery Sounder Transformer Option switches Connection Terminals Battery charging LED Battery ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 ...

Страница 6: ... button Con firmed Tamper return Strobe Hold Off Pos Hold Off Neg Test Siren Fault Int 3m 15M N P Trig H L Vol N P Tamp Siren Antenna Diagnostic LEDs Tamper switch Enrolment button Option switches Connection Terminals Wire free PCB Layouts Control Panel Module CPM Grade 2 only Warning Device WD Grade 2 only Green Red ON 1 2 3 4 5 6 ...

Страница 7: ... Strobe A signal from the control panel to activate the strobe LED Plus Standard CPM 3 Siren A signal from the control panel to activate the siren LED Plus Standard CPM 2 Hold off Positive ve A permanent positive DC supply from the control panel Plus Standard CPM 1 Hold off Negative 0v A permanent negative DC supply from the control panel Terminal Description DIP Switch Settings PLUS models Standa...

Страница 8: ...the box Drill 3 holes using a 5 5mm masonry drill 41mm deep for the enclosed wall plugs insert the wall plugs into the holes fit the top centre screw enclosed leaving it protruding by 25mm Feed the cable through the cable entry point on the Senza and carefully slot the top fixing point of the Senza over the previously installed screw rotate the 2 x bottom fixing points if necessary to allow the ho...

Страница 9: ...s etc Large metal objects a distance of 1m is recommended Temporarily place the unit in the selected location do not hold ensuring that the CPM is vertical using the built in coms feature in the warning device ensure that there is communication between the warning device and the CPM see page 12 if not move the location of the CPM and repeat the process Mount the CPM in the selected location connec...

Страница 10: ...3 Plug in the battery and one bleep will be heard 4 Ensure the tamper switch will close properly and fit the lid two bleeps will be heard 5 The tamper LED should start to flash twice a second 6 This will stay like this until hold off voltage is applied or the battery goes flat 7 Connect the control panel as indicated below 8 Apply power to the Senza 9 Both the hold off LED and the tamper LED will ...

Страница 11: ...applied or the battery goes flat 7 Connect the control panel as indicated below 8 If Trigger wire monitoring is selected the 2 x 1kΩ resistors must be fitted prior to power up G3 requirement 9 Apply power to the Senza 10 Both the hold off LED and the tamper LED will now flash Two bleeps will be heard 11 After a few seconds the unit will bleep again and the LED s will flash alternately 12 After 5 m...

Страница 12: ... connections below ensuring that the DIP switches are set to your requirements The Green and Red LEDs should flash alternately 2 Connect the battery in the WD The CPM and WD should automatically pair This is indicated by the Green LED on the WD flashing every 2 seconds If not refer to Installation and operating instructions on How to pair 3 During the next 30 minutes the WD will be in engineer mod...

Страница 13: ...Page 13 of 16 v3 1 Fitting Covers Cover Lock UnLock ...

Страница 14: ...s indicates that the tamper protection for the cover and or the removal from wall is open If the Red LED stops flashing this indicates that there is no voltage on the Hold off terminals The Red battery LED is illuminated when the battery is healthy If the LED is extinguished this indicates that the battery is disconnected or faulty Wired models Please refer to the DIP switch setting on page 7 to s...

Страница 15: ...009 Warning device Type Z Warning Device WD Battery Type Lithium Manganese Dioxide non rechargeable Nominal Voltage 3 volt Capacity 4700mAh Approximate life 2 years depending on the number and duration of activations Current Consumption Quiescent 3 5mA Alarm Sounder Strobe 245mA Sounder Type Piezo Acoustic Output Tone Sound duration 15 minutes 3 minutes or intermittent Sound Output Levels 105db A ...

Страница 16: ... suffocate always dispose of packaging carefully Order code Description BCSENZ S STD W Senza S Grade 2 Backplate White BCSENZ S PLUS W Senza S Grade 2 3 Backplate White BCSENZ S PLUS L W Senza S Grade 2 3 Backplate White with Backlight BCSENZ S WF W Senza S Wirefree Kit White WD CPM BCSENZ S COV W B Senza S Cover White with Blue Lens BCSENZ S COV W B L Senza S Cover White with Blue Lens with Backl...

Отзывы: