In  standby  mode,  press  the  scroll,  down  arrow  and  up  arrow 

buttons simultaneously for 3 seconds, and the keyboard will be 

locked. 
When the keyboard is locked, press and hold the scroll, down 

arrow and up arrow buttons for 3 seconds, and the keyboard will 

unlock

 

When the heat pump is running and the power supply 

is suddenly interrupted, the system, once powered up, will restart from the last mode 

set.

 

 

 
Frequently check the hydraulic circuit and cleanliness of the water entering the device. Avoid dry running or the entry 

of air into the hydraulic circuit, which would negatively affect the performance and reliability of the unit. 
It is advisable to clean the filtration system upstream of the unit regularly to avoid damage to it. Maintain a dry, clean 
and properly ventilated environment around the unit. 
Clean the condenser regularly. 
Check the power cable to see if you perceive a bad smell from the electrical component. If so, contact the installer 

immediately. 
Please drain all the water present in the heat pump at the beginning of the winter period, for proper wintering of the 
device. 
It is necessary to completely drain the water from the pump if the unit stops for a long time. After a period of standstill, 
before starting the unit again, completely fill the 
hydraulic circuit of the by-pass and the pump.

 

7. 

KEYBOARD LOCK

 

8. 

MEMORY BACKUP AFTER POWER RESUME

 

9. 

MAINTENANCE

 

Содержание 1041130

Страница 1: ...USER MANUAL Ver 06 2018 05 28 C P A S R L HEAT PUMPS USER MANUAL BLUEFIRE SERIES ...

Страница 2: ...MENSIONS 8 PRELIMINARY SIZING OF CONNECTION CABLES 8 OPERATIVE GUIDE 9 1 CONTROL KEYBOARD DESCRIPTION 9 2 WORK STATE CONTROL 10 3 STATUS MENU PARAMETERS PROGRAMMING 10 4 Programming parameter list 11 5 Time settings 12 6 Programmed start stop by clock 12 7 Keyboard lock 13 8 Memory backup after power is resumed 13 9 Maintenance 13 10 Alarm codes 14 11 PCB connections diagram 15 12 Connection diagr...

Страница 3: ...low pressure of the refrigerant circuit 5 Automatic protection stop for excess temperature 6 Self defrosting to guarantee optimal operation even in low temperature environments 7 Steel body with pre painting fixed to the oven 8 Constant heating and cooling function usable for swimming pools and SPAs 9 Anti running idle flow sensor INSTALLATION WARNING The heat pump must only be installed by qualif...

Страница 4: ...ting from its operation must be evacuated correctly note any condensation at the foot of the heat pump is proof of correct operation in no case can it be considered as a loss of coolaIl supporto della pompa di calore deve essere stabile e solido Ground installation best prepare a concrete slab about ten cm thick at least the size of the machine base Installation in height the support and its fixin...

Страница 5: ...heat pump and the water flow that does not pass through it so to obtain the debt incurred through the heat pump compare the table A valve positioned near the pump on the water inlet pipe A valve positioned near the pump on the water outlet p These last two valves are usually always in the open position they must be closed only when it is necessary to intervene on the pump circuit or to disassemble...

Страница 6: ...ected before starting to increase the disinfectant concentration and wait for this value to return to normal before re opening the valves To limit heat dispersion in the pipes connecting the pump to the swimming pool circuit it is recommended not to move the heat pump more than 10 meters away from the swimming pool Beyond a certain length the pipes must be buried at a sufficient depth take into ac...

Страница 7: ...0 40 a 50 SENIOR SERIES TECHNICAL FEATURES Code 1041133 1041134 1041140 1041135 1041136 1041137 Model SBR 14 0H B SBR 17 0H B SBR 17 0H B S SBR 21 0H B S SBR 26 0H B S SBR 45 0H A S Power returned at 26 C of air temperature kW 14 00 17 00 17 00 21 00 26 00 45 00 C O P 4 80 4 70 4 70 4 60 4 80 4 50 EER 3 50 3 50 3 50 3 30 3 30 3 2 Recommended water flow m3 h 5 a 8 5 a 8 5 a 8 6 a 10 6 a 12 8 a 15 N...

Страница 8: ...RY SIZING OF CONNECTION CABLES 2 SBR 3 8H B SBR 5 3H B 1 5 mm2 3 SBR 9 5H B SBR 11 3H B SBR 14 0H B SBR 17 0H B 2 5 mm2 3 SBR 17 0H B S SBR 21 0H B S SBR 26 0H B S 2 5 mm2 5 SBR 45 0H A S 4 0 mm2 5 1 The letter s indicates that the machine must be powered with three phase current The operation of the heat pumps is guaranteed within a range of temperature that varies between 0 C and 43 2 The follow...

Страница 9: ...the SET button it selects and modifies the working parameters set in the programming menu WARNING Changing the factory default parameters is only possible when the pump is in stand by Changing these values must only be carried out by qualified personnel Allows you to access the device programming menu display Together with the buttons scroll up and scroll down select and modify the working paramet...

Страница 10: ...s the system automatically returns to its initial state WARNING To change the value of the status parameters the heat pump must be in stand by and not working Press the SET button once to display the 13 status parameter selection menu Use the SET button to view and scroll through the 13 parameters set in default and reach the field that you want to change see par 4 List of programming parameters T...

Страница 11: ...C Adjustment can only be carried out by a qualified technician 5 Time duration for exiting the defrost mode in heating mode 1 12MIN 8MIN Adjustment can only be carried out by a qualified technician 6 Number of compressors per system 1 2 1 Adjustment can only be carried out by a qualified technician the value is set on 2 only from model SBR 35 onwards 7 Automatic restart 0 1 1 Adjustment can only b...

Страница 12: ...BLUEFIRE HEAT PUMPS MANUAL pag 12 di 20 www cpa piscine it Ver 06 2018 05 28 ...

Страница 13: ...lashing hours Press the button again to change the start time With the buttons scroll up scroll down to move in order to select the desired number of hours and minutes Repeat the operation described above to adjust the minutes Then press the button again to be able to change the shutdown time With the buttons scroll up scroll down to move in order to select the desired number of hours and minutes ...

Страница 14: ...rcuit which would negatively affect the performance and reliability of the unit It is advisable to clean the filtration system upstream of the unit regularly to avoid damage to it Maintain a dry clean and properly ventilated environment around the unit Clean the condenser regularly Check the power cable to see if you perceive a bad smell from the electrical component If so contact the installer im...

Страница 15: ... Water temperature Too short Malfunzionamento del sistema 1 modello trifase EE01 System protection 1 has failed Check each protection point of the system and remove any malfunction Protezione alte basse temperature EE01 Gas pressure of system too high or too low Check the coolant pressure Malfunzionamento del sistema 2 EE02 System protection 2 failed Check each protection point of the system and r...

Страница 16: ...sed 7 COMP1 System Compressor 1 220VAC 8 AC L Active connection 9 AC N Neutral connection 10 KYOUT GND On Off sensor 11 KYOUT GND Output mode 12 NET GND 12V Keyboard 13 KYIN On off sensor 14 MDIN Template 15 WATER GND Flow sensor 16 FROST GND Defrost signal not used 17 SYS GND 12V System protection 18 ROOMT External ambient temperature 19 PIPE2 Fan circuit 2 temperature not used 20 PIPE1 Fan circu...

Страница 17: ...BLUEFIRE HEAT PUMPS MANUAL pag 17 di 20 www cpa piscine it Ver 06 2018 05 28 12 CONNECTION DIAGRAMS Version SBR 3 8H B SBR 5 3 H B SBR 9 5 H B Version SBR 11 3H B ...

Страница 18: ...BLUEFIRE HEAT PUMPS MANUAL pag 18 di 20 www cpa piscine it Ver 06 2018 05 28 Version SBR 14 OH B Version SBR 17 OH B ...

Страница 19: ... HEAT PUMPS MANUAL pag 19 di 20 www cpa piscine it Ver 06 2018 05 28 Version SBR 17 0H B S SBR 21 0H B S SBR 26 0H B S Version 45 AH S NOTA Crankshaft Heater seppur raffigurati non sono attualmente disponibili ...

Страница 20: ...ercurrent protection of the compressor the system detects the compressor phases phase 1 or 2 for three seconds If current phase 1 or 2 1 the system enters the overcurrent protection phase error code 5 If current phase 1 or 2 1 the system exits the overcurrent protection 2 Protection from high temperatures for gas compression the system detects the contact status of the high temperature safety sens...

Страница 21: ...in this document have a purely informative value and are not valid for regulatory purposes All operations must be performed in a workmanlike manner and exclusively by qualified personnel in possession of the requisites required by current regulations It is essential that the installation is carried out by competent and qualified personnel in possession of the technical requirements required by the...

Отзывы: