22
ver.071217-2.10
iLEARN
System Manual
iLEARN Door Control Menu Screens
(continued)
NOTE
: Using the MENU/Select Knob, select the appropriate iDRIVE VFD Control. iDRIVE
Unit Addresses (e.g. 01, 02, 03) correspond to their position on your COURION CANbus
Network.
1.3.1 Comm Rate -
This is the number of good command/reply transactions between the iL-
earn and this drive in the last second. Approximately 240 transactions per second are shared
by all slaves on the network. For example, if there are 6 door openings and 2 car gates, this
number would be around 30 for a noise free network.
1.3.2 Open iSENSOR Flags -
07 – This bit indicates the last detected direction of motion. ‘1’
indicates that the door magnet is moving TOWARDS the Open iSENSOR (Open Direction); ‘0’
indicates that the door magnet is moving AWAY from the Open iSENSOR (Close Direction).
1.3.3 Open iSENSOR Position -
Used to indicate door position relative to FULL OPEN. This
is not done initially because these values are relative to door position when the iSENSORs are
powered up. If powered up at FULL OPEN, then the position will be near 12”.
1.3.4 Full Open Position -
This is the value of the “Open iSENSOR Position” register where
the door stalls in the open position.
1.3.5 Open iSENSOR Speed -
This is actually the period between alternating poles. It is non-
zero when the magnet is moving over the sensor and zero when the magnet is not moving.
1.3.6 Close iSENSOR Flags -
07 – This bit indicates the last detected direction of motion. ‘1’
indicates that the door magnet is moving TOWARDS the Closed iSENSOR (Close Direction);
‘0’ indicates that the door magnet is moving AWAY from the Close iSENSOR (Open Direction).
1.3.7 Close iSENSOR Position -
Used to indicate door position relative to FULL CLOSE. This
is not done initially because these values are relative to door position when the iSENSORs are
powered up. If powered up at FULL OPEN, then the position will be near 0”.
1.3.8 Close Limit Position -
This is the value of the “Close iSENSOR Position” register where
the door stalls in the closed position.
1.3.9 Close iSENSOR Speed -
This is actually the period between alternating poles. It is non-
zero when the magnet is moving over the sensor and zero when the magnet is not moving.
1.3.10 Digital Inputs (iDRIVE VFD Control) -
These bits represent the state of the digital
inputs presented to the iDrive. A ‘1’ indicates a CLOSED circuit. A ‘0’ represents an OPEN
circuit.
06 - Request For Address - is provided by the previous iDRIVE or iLEARN in the network
Содержание iDRIVE
Страница 8: ...8 ver 071217 2 10 iLEARN System Manual PA PAE INTERLOCK PO 70 3A...
Страница 14: ...14 ver 071217 2 10 iLEARN System Manual iLEARN Door Control...
Страница 19: ...19 ver 071217 2 10 iLEARN System Manual...
Страница 20: ...20 ver 071217 2 10 iLEARN System Manual...
Страница 36: ...36 ver 071217 2 10 iLEARN System Manual iDRIVE VFD Floor Control...
Страница 38: ...38 ver 071217 2 10 iLEARN System Manual iDRIVE G Car Top Control...
Страница 41: ...41 ver 071217 2 10 iLEARN System Manual...
Страница 63: ...63 ver 071217 2 10 iLEARN System Manual Doors Closing Doors Opening...