Operation
Page 3
Operation & Maintenance Manual - Vision Chilled Displays
OPERATION
It is essential that you read the instructions carefully and follow all of the cleaning and maintenance
instructions. Failure to do so can result in premature failure that will not be covered by warranty.
Vision chilled display units are designed to merchandise chilled food maintaining food temperatures by using re-circulated
cold air.
Each shelf level is illuminated by a fluorescent strip light for optimum product presentation. Assisted service units have full
height curved glass sneeze screen.
All units have solid glass ends and either fixed rear panels or double-glazed doors. The principles of operation and cleaning
are the same for all models whether self help or assisted service, floor mounted or tabletop.
If you have any difficulties or need advice please do not hesitate to call our Service department on
0151 548 2211
. Make
sure that you have the unit serial number to hand before calling.
Vision units are available as stand-alone units with an integral base or as a drop-in unit with under-slung compressor. The
basic operation and maintenance of these units is the same.
1.0 - SWITCHING YOUR VISION CHILLED DISPLAY UNIT ON
Info / Set point button
Manual defrost / decrease button
Manual activation/ increase button
Stand-by button
INDICATIONS
CONTROLLER SET UP
BUTTONS
The digital controller controls both the circulating air temperature and the defrost cycles. It is pre-set to an average air tem-
perature of 0°C, which should maintain food below 5 °C in an ambient temperature below 25 °C.
At this stage there is no need to alter this or any other setting of the digital controller.
1.1 - FAULT ON SWITCHING ON
If after the operation of the main power switch on the control panel it does not illuminate:
1.
Check that your Idesign unit has been connected to a mains supply by your installer, and that this supply is live.
2.
Isolate the unit and check the supply fuse.
3.
Take care to ensure that you replace a fuse with one of the same rating. If you can find no fault call your installer for
help.