Standard Operation Procedure
8
Tray Drain Plug
The Tray Drain allows for water to drain from
the tray when cleaning or sanitizing. The drain
can be opened pulling the plug from the metal
drain tube to allow water to drain into a
bucket. When reinserting the drain plug, verify
that it is clean and lubricated.
Figure 13: Tray Drain Plug
Air Pressure Regulator
The air pressure regulator is used to maintain
a constant pressure in the system. Avoid
pressure drops greater than 10psi. If the
pressure does drop more than 10psi, the CFM
being supplied to the depositor may be too
low. Maintain a consistent air pressure in the
system (80-90psi) to achieve best results.
Figure 14: Air Pressure Regulator
Adjusting the Air Pressure
To adjust the air pressure, pull out on the
black knob and rotate. Be sure to lock the
regulator after adjustment.
*WARNING: Never set the air pressure higher
than 125psi!
Figure 15: Adjusting the Air Pressure