6 - INSTALLATION
6.14 - Installation of the safety kit in the
GB indoor unit
The safety kit is supplied from the factory in the accessories
bag (section 2.2), which includes hydrometer, safety valve and
automatic air vent valve (Figure 6-11). Mount the safety kit as
follows:
1.- Apply sealing tape on the 1“ fitting (item ”1” in Figure
3-1) located on the upper side of the indoor unit (step 2 of
Figure 6-12);
2.- Mount the safety kit (item “1” Figure 6-12) on the 1“ fitting
in accordance with the identification sticker (step 3 of
Figure 6-12);
3.- Connect the safety valve drain with a pipe to a house drain,
as shown in step “4” of Figure 6-12;
4.- After installing the kit, the air vent valve screw must be
loosened to allow the air to escape from the circuit.
Figure 6-11 - Safety kit
Figure 6-12 - Fitting the safety kit
1
4
3
2